A transcutaneous energy transmission system with rechargeable internal back-up battery for a totally implantable total artificial heart.

Reads0
Chats0
TLDR
The transcutaneous energy transmission and the charging control characteristics of the ECTETS, while simultaneously supplying energy to the TITAH and the RIBB, were evaluated in an in vitro experiment and it may, reasonably, reasonably be concluded that theECTETS with the R IBB is sufficient to drive theTITAH.
Abstract
We have been developing an externally coupled transcutaneous energy transmission system (ECTETS) for a totally implantable total artificial heart (TITAH). When the ECTETS is unable to supply the energy to drive the TITAH from outside the body, a rechargeable internal back-up battery (RIBB) implanted inside the body is used as a back-up to supply the required energy. This paper reports on the performance characteristics of our ECTETS with an RIBB. In this study, a lithium-ion (Li+) secondary battery was used as the RIBB. The transcutaneous energy transmission and the charging control characteristics of the ECTETS, while simultaneously supplying energy to the TITAH and the RIBB, were evaluated in an in vitro experiment. The output power and transmission efficiency of the ECTETS operating in this mode were found to vary from 20 W to 34 W and from 84% to 71%, respectively. It was also found that a sufficient power of more than 20 W could be supplied to the TITAH. The time needed to fully charge the RIBB was 117 minutes, and a fully charged RIBB could drive the TITAH, consuming 20 W for 62 minutes. It may, therefore, reasonably be concluded that the ECTETS with the RIBB is sufficient to drive the TITAH.

read more

Citations
More filters
Journal ArticleDOI

Analysis of Current Density and Specific Absorption Rate in Biological Tissue Surrounding Transcutaneous Transformer for an Artificial Heart

TL;DR: The results of simulation analysis show SARs to be very small at any given transmission conditions, compared to the basic restrictions of the International Commission on nonionizing radiation protection (ICNIRP; 2 W/kg), while the current density divided by the ICN IRP's basic restrictions gets smaller as the frequency rises and the output voltage falls.
Journal ArticleDOI

A new transcutaneous energy transmission system with hybrid energy coils for driving an implantable biventricular assist device.

TL;DR: The new transcutaneous energy transmission (TET) system for a totally implantable biventricular assist device (BVAD) system in the NEDO artificial heart project can overcome the drawback of previously reported TET systems, and it promises to be the highest performance TET system in Britain.
Journal ArticleDOI

Percutaneous devices: a review of applications, problems and possible solutions

TL;DR: For the majority of the locations on the abdomen or chest, no solution for an infection-free device has been found and a solution may be possible with a better understanding of the physiology of keratinocytes as a barrier for microbes.
Journal Article

Functions for detecting malposition of transcutaneous energy transmission coils.

TL;DR: In this article, a transcutaneous energy transmission system (TETS) for artificial heart and ventricular assist devices uses electrical coupling of power between external and implanted coils, and the position of coils changes relative to each other.