scispace - formally typeset
Journal ArticleDOI

Adaptive frequency domain control of PWM switched power line conditioner

S.M. Williams, +1 more
- Vol. 6, Iss: 4, pp 665-670
Reads0
Chats0
TLDR
In this paper, an adaptive frequency domain control algorithm for a PWM switched active power line conditioner (PLC) is discussed, which minimizes harmonic current in the AC line and improves power factor to unity.
Abstract
An adaptive frequency domain control algorithm for a pulse width modulation (PWM) switched active power line conditioner (PLC) is discussed. An active power line conditioner that minimizes harmonic current in the AC line and improves power factor to unity is recommended. A six switch pulse width modulated current source inverter implements the active PLC. Simulation results of the PLC adaptive frequency domain control using the PWM switching algorithm are presented. >

read more

Citations
More filters
Journal ArticleDOI

A review of active filters for power quality improvement

TL;DR: This paper presents a comprehensive review of active filter configurations, control strategies, selection of components, other related economic and technical considerations, and their selection for specific applications.
Journal ArticleDOI

Active power filters: a review

TL;DR: There has been considerable interest in the development and applications of active filters because of the increasing concern over power quality, at both distribution and consumer levels, and the need to control reactive power and voltage stability at transmission levels as mentioned in this paper.
Journal ArticleDOI

Controllability and reachability criteria for switched linear systems

TL;DR: Complete geometric criteria are presented for controllability and reachability of switched linear systems.
Journal ArticleDOI

Detection is key - Harmonic detection methods for active power filter applications

TL;DR: In this article, a survey of the commonly used methods for harmonic detection in active power filters (APFs) is presented, and a simulation setup that decouples the harmonic detection method from the active filter model and its controllers is proposed.
Journal ArticleDOI

Switched Controller Synthesis for the Quadratic Stabilisation of a Pair of Unstable Linear Systems

TL;DR: Three stabilising control strategies are discussed: time average control, a variable structure control, and a hybrid feedback control for quadratically stabilising the state trajectory by switching between the two unstable systems.
References
More filters
Journal ArticleDOI

Design of Filters to Reduce Harmonic Distortion in Industrial Power Systems

TL;DR: In this paper, the design and performance of single-tuned and high-pass filters and the methodology used for the analysis were discussed, and the performance evaluation criteria used for performance evaluation are losses, current, and voltage ratings of each of the filter components.
Journal ArticleDOI

The Effects of Power System Harmonics on Power System Equipment and Loads

TL;DR: In this paper, the authors present a summary of current knowledge regarding the effects of power system harmonics on system equipment and loads, and promote a discussion with those closely involved with each of the various load types.
Journal ArticleDOI

Adjustable Speed Drive and Power Rectifier Harmonics-Their Effect on Power Systems Components

TL;DR: The use of the electrochemical rectifiers and the increasing application of ac and dc adjustable speed drives dictates that the effect of harmonic "pollution" on other equipment in the power system be considered as discussed by the authors.
Journal ArticleDOI

A harmonic filter installation to reduce voltage distortion from static power converters

TL;DR: In this paper, the design, construction, and testing of a harmonic filter installation to meet IEEE 519 for a particularly adverse application is described, and a method is proposed for confirming filter performance under factory test conditions that differ significantly from the design conditions.
Journal ArticleDOI

The Effect of Harmonics on the Operating Points of Electromechanical Relays

TL;DR: In this paper, the effect of harmonics on the operating points of three types of relays, namely the instantaneous overcurrent, instantaneous voltage and time overcurrent types, was investigated.
Related Papers (5)