Proceedings ArticleDOI
Arterial compliance probe for calibration free pulse pressure measurement
Jayaraj Joseph,P M Nabeel,Malay Ilesh Shah,Mohanasankar Sivaprakasam +3 more
- pp 1-6
Reads0
Chats0
TLDR
Initial results indicate a strong potential of MPG - Ultrasound arterial compliance probe in continuous, cuffless evaluation of blood pressure (BP) from superficial arteries.Abstract:
Cardiovascular diseases are the leading cause of death around the world. Non-invasive estimation of arterial parameters is significant in the early detection of cardiovascular diseases. In this work, we present an arterial compliance probe for calibration-free evaluation of carotid pulse pressure. This novel cuffless measurement technique uses dual magnetic plethysmograph (MPG) transducers for carotid local pulse wave velocity (PWV) measurement and single element ultrasound transducer for measuring arterial dimensions. Proposed arterial compliance probe can acquire two blood pulse waveforms and arterial diameter parameters simultaneously, which are then utilized in cycle-to-cycle estimation of arterial local PWV and pulse pressure without any subject or population specific calibration. The design of compliance probe and measurement system was verified by in-vivo trials. Accurate local PWV measurement and calibration free estimation of carotid pulse pressure was also validated by in-vivo studies. Initial results indicate a strong potential of MPG — Ultrasound arterial compliance probe in continuous, cuffless evaluation of blood pressure (BP) from superficial arteries.read more
Citations
More filters
Journal ArticleDOI
Continuous Blood Pressure Measurement From Invasive to Unobtrusive: Celebration of 200th Birth Anniversary of Carl Ludwig
Xiaorong Ding,Ni Zhao,Guang-Zhong Yang,Roderic I. Pettigrew,Benny Lo,Fen Miao,Ye Li,Jing Liu,Yuan-Ting Zhang +8 more
TL;DR: This review summarizes the key milestones in continuous BP measurement; that is, kymograph, intraarterial BP monitoring, arterial tonometry, volume clamp method, and cuffless BP technologies.
Journal ArticleDOI
Arterial Blood Pressure Estimation From Local Pulse Wave Velocity Using Dual-Element Photoplethysmograph Probe
TL;DR: An arterial compliance, dual-element photoplethysmograph probe for local pulse wave velocity (PWV) measurement has a potential for short- or long-term noninvasive, cuffless monitoring of BP parameters from superficial arteries.
Journal ArticleDOI
Non-invasive continuous blood pressure monitoring systems: current and proposed technology issues and challenges
TL;DR: Most advanced and standard technologies including pulse transit time (PTT), ultrasound, pulse arrival time (PAT), and machine learning are investigated and the accuracy, portability, and comfort of use of these technologies, and the ability to integrate to the wearable healthcare system are discussed.
Journal ArticleDOI
Pre-ejection period, the reason why the electrocardiogram Q-wave is an unreliable indicator of pulse wave initialization.
Joel Balmer,Christopher G. Pretty,Shaun Davidson,Thomas Desaive,Shun Kamoi,Antoine Pironet,Philippe Morimont,Nathalie Janssen,Bernard Lambermont,Geoffrey M. Shaw,J. Geoffrey Chase +10 more
TL;DR: The overall analysis shows PAT is an unreliable measure of PTT and a poor surrogate under clinical interventions common in a critical care setting, due to intra- and inter- subject variability in PEP.
Proceedings ArticleDOI
Measurement of carotid blood pressure and local pulse wave velocity changes during cuff induced hyperemia
TL;DR: The ability of developed PPG probe and associated measurement system to detect acute changes in carotid local pulse wave velocity due to blood pressure variations was experimentally validated by an in-vivo study and demonstrated the feasibility of real-time signal acquisition and reliable local PWV evaluation under normal and elevated BP conditions using the developed measurement system.
References
More filters
Book
McDonald's Blood Flow in Arteries: Theoretical, Experimental and Clinical Principles
TL;DR: The nature and flow of a fluid properties of the normanl arterial wall changes to properties of that wall pulsatile pressure flow relationships measuring principles of arterial waves ultrasonic techniques and measurements contour of pressure and flow waves in arteries wave reflection are studied.
Velocity of the Pulse wave in Man
TL;DR: The following pages contain the results arrived at, together with an account of experiments upon the velocity of the pulse wave in an isolated human artery, from an investigation now being carried out at Manchester.
Journal ArticleDOI
The Velocity of the Pulse Wave in Man
TL;DR: In this paper, the velocity of the pulse wave in an isolated human artery was investigated, under various conditions, and the results arrived at, together with an account of experiments upon the velocity.
Journal ArticleDOI
Determination of pulse wave velocities with computerized algorithms
TL;DR: Investigation of the efficacy of four computerized algorithms in the determination of pulse wave velocities in invasive as well as in noninvasive pressure determinations found them to be accurate.
Journal ArticleDOI
Pulse Pressure, Arterial Stiffness, and Drug Treatment of Hypertension