scispace - formally typeset
Journal ArticleDOI

Circular position sensitive Si(Li) detector with large area and its application as cosmic ray isotope identifier

Reads0
Chats0
TLDR
In this article, a large area circular position sensitive Si(Li) detectors of 70 mm in diameter were developed, and the linear relation between output signals and incident positions was shown to be in good agreement with the result of electrolytic bath experiments.
About
This article is published in Nuclear Instruments and Methods.The article was published on 1975-12-15. It has received 11 citations till now.

read more

Citations
More filters
Journal ArticleDOI

Position-sensitve semiconductor detectors

TL;DR: In this paper, a review of solid-state radiation detectors for simultaneous determination of charged particle position and energy is presented, with particular emphasis devoted to the operational conditions, which are of importance for the performance of such devices, and examples of distortion and resolution reflecting inherent limitations.
Journal ArticleDOI

A 4-inch silicon/tungsten calorimeter for p-p collider experiments

TL;DR: In this paper, a 4-inch diameter silicon/tungsten sandwich calorimeter with 64 cm 2 in active area and 18 radiation lengths in depth has been constructed and the performance has been investigated for incoming electrons of 500 MeV to 4.5 GeV.
Journal ArticleDOI

A Si(Li)-Pb shower calorimeter for p-p collider experiments

TL;DR: In this article, a silicon/lead sandwich calorimeter with 38 cm 2 in active area and 10 radiation lengths in depth has been constructed and the performance has been investigated for incoming electrons of 250 to 750 MeV.
Journal ArticleDOI

A silicon counter array for 2He detection

TL;DR: In this paper, a multicounter array consisting of four Si detector telescopes was developed for the coincidence measurement of two protons with small relative energy (2He), and a compact amplifier system was developed using low-noise hybrid ICs to treat many signals from the counter array.
References
More filters
Journal ArticleDOI

Si(Li) position sensitive detector

TL;DR: In this article, a position sensitive detector was made using the lithium diffused layer of a lithium-drifted-silicon detector as the uniform resistive layer, and an expression was derived for estimating the resistance from the thickness of the lithium layer.
Journal ArticleDOI

Cosmic ray isotope and charge resolution using large area scintillation-cherenkov-total energy telescopes

TL;DR: In this article, the response to multiply charged cosmic rays of two very large area counter telescopes employing d E d x, total energy and Cherenkov detecting elements has been studied.
Related Papers (5)