TLDR
Power law parameters of the phantoms were close to those of the patients but no single phantom matched in terms of both magnitude (κ) and texture (β) for the x-ray systems in this work.
Abstract
Purpose: This work characterizes three candidate mammography phantoms with structured background in terms of power law analysis in the low frequency region of the power spectrum for 2D (planar) mammography and digital breast tomosynthesis (DBT). Methods: The study was performed using three phantoms (spheres in water, Voxmam, and BR3D CIRS phantoms) on two DBT systems from two different vendors (Siemens Inspiration and Hologic Selenia Dimensions). Power spectra (PS) were calculated for planar projection, DBT projection, and reconstructed images and curve fitted in the low frequency region from 0.2 to 0.7 mm−1 with a power law function characterized by an exponent β and magnitude κ. The influence of acquisition dose and tube voltage on the power law parameters was first explored. Then power law parameters were calculated from images acquired with the same anode/filter combination and tube voltage for the three test objects, and compared with each other. Finally, PS curves for automatic exposure controlled acquisitions (anode/filter combination and tube voltages selected by the systems based on the breast equivalent thickness of the test objects) were compared against PS analysis performed on patient data (for Siemens 80 and for Hologic 48 mammograms and DBT series). Dosimetric aspects of the three test objects were also examined. Results: The power law exponent (β) was found to be independent of acquisition dose for planar mammography but varied more for DBT projections of the sphere-phantom. Systematic increase of tube voltage did not affect β but decreased κ, both in planar and DBT projection phantom images. Power spectra of the BR3D phantom were closer to those of the patients than these of the Voxmam phantom; the Voxmam phantom gave high values of κ compared to the other phantoms and the patient series. The magnitude of the PS curves of the BR3D phantom was within the patient range but β was lower than the average patient value. Finally, PS magnitude for the sphere-phantom coincided with the patient curves for Siemens but was lower for the Hologic system. Close agreement of doses for all three phantoms with patient doses was found. Conclusions: Power law parameters of the phantoms were close to those of the patients but no single phantom matched in terms of both magnitude (κ) and texture (β) for the x-ray systems in this work. PS analysis of structured phantoms is feasible and this methodology can be used to suggest improvements in phantom design.

read more

Citations
More filters
Journal ArticleDOI

Evaluation of Digital Breast Tomosynthesis as Replacement of Full-Field Digital Mammography Using an In Silico Imaging Trial.

TL;DR: An improved lesion detection performance favoring tomosynthesis for all breast sizes and lesion types is found, suggesting that in silico imaging trials and imaging system computer simulation tools can in some cases be considered viable sources of evidence for the regulatory evaluation of imaging devices.
Journal ArticleDOI

Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

TL;DR: The development of a new suite of physical breast phantoms based on human data that offer realistic breast anatomy, patient variability, and ease of use and are a potential candidate for performing both system quality control testing and virtual clinical trials.
Journal ArticleDOI

Tissue mimicking materials for imaging and therapy phantoms: a review.

TL;DR: This review investigates the specifications that are typically being used in development of the latest TMMs and investigates the imaging modalities that have been investigated focus around CT, mammography, SPECT, PET, MRI and ultrasound.
Journal ArticleDOI

DukeSim: A Realistic, Rapid, and Scanner-Specific Simulation Framework in Computed Tomography

TL;DR: DukeSim, when combined with realistic human phantoms, provides the necessary toolset with which to perform large-scale and realistic virtual clinical trials in a patient and scanner-specific manner.
Journal ArticleDOI

A novel physical anthropomorphic breast phantom for 2D and 3D x-ray imaging.

TL;DR: A novel, realistic breast phantom can be created using an analytically defined breast model and readily available materials using a method for rapidly creating realistic, inexpensive physical anthropomorphic phantoms for use in full‐field digital mammography and digital breast tomosynthesis.
References
More filters
Journal ArticleDOI

On the use of windows for harmonic analysis with the discrete Fourier transform

F.J. Harris
TL;DR: A comprehensive catalog of data windows along with their significant performance parameters from which the different windows can be compared is included, and an example demonstrates the use and value of windows to resolve closely spaced harmonic signals characterized by large differences in amplitude.
Journal ArticleDOI

Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocol

TL;DR: The UK and European protocols for mammographic dosimetry use conversion factors that relate incident air kerma to the mean glandular dose (MGD) within the breast as discussed by the authors.
Journal ArticleDOI

X-ray characterisation of normal and neoplastic breast tissues.

TL;DR: Analysis based on the average attenuation properties of tissues indicates that dual-energy mammography, using an ideal imaging system, would require 0.06 cGy to provide images in which 1 cm infiltrating duct carcinomas are displayed with a signal to noise ratio of 5 against a background over which the fat/fibrous contrast has been suppressed.
Journal ArticleDOI

Human observer detection experiments with mammograms and power-law noise.

TL;DR: The conclusion is that, in spite of the fact that mammographic backgrounds have nonstationary statistics, models based on statistical decision theory can still be applied successfully to estimate human performance.
Journal ArticleDOI

DQE(f) of four generations of computed radiography acquisition devices

TL;DR: There has been substantial improvement in the imaging performance obtainable with CR since some of the early observer studies which indicated poorer performance with CR than with screen-film.
Related Papers (5)