Heart Rhythm Analysis using ECG Recorded with a Novel Sternum based Patch Technology - A Pilot Study

Reads0
Chats0
TLDR
The conclusion of this pilot study indicates that two channel ECG recorded on the sternum is useful for rhythm analysis and could be used as input to diagnosis together with other clinical tests and medical history.
About
This article is published in International Congress on Cardiovascular Technologies.The article was published on 2018-09-06 and is currently open access. It has received 72 citations till now. The article focuses on the topics: Sternum (arthropod anatomy).

read more

Citations
More filters
Journal ArticleDOI

Automatic Real-Time Embedded QRS Complex Detection for a Novel Patch-Type Electrocardiogram Recorder

TL;DR: The algorithm is based on a novel cascade of computationally efficient filters, optimized adaptive thresholding, and a refined search back mechanism and validated with high clinical performance on more than 300 ECG records from 189 different subjects with a high number of different abnormal beat morphologies.
Patent

Remote Interfacing of Extended Wear Electrocardiography and Physiological Sensor Monitor

TL;DR: In this paper, a wearable monitor that includes two components, a flexible extended wear electrode patch and a removable reusable monitor recorder, is used to provide physiological monitoring in a chest X-ray.
Patent

Extended wear electrocardiography patch using interlaced wire electrodes

TL;DR: In this paper, a flexible extended wear electrode patch and a removable reusable monitor recorder are used for physiological monitoring, where a pair of flexile wires are interlaced or sewn into a flexible backing, serving as electrode signal pickup and electrode circuit traces.
Patent

Extended wear electrocardiography patch

TL;DR: In this paper, a flexible extended wear electrode patch and a removable reusable monitor recorder are used to sense cutaneously cardiac electric signals, particularly those generated by the atrium, and a strain relief is defined in the electrode patch's flexible circuit using cutouts partially extending transversely from each opposite side of the flexible circuit.
Patent

Computer-Implemented System And Method For Providing A Personal Mobile Device-Triggered Medical Intervention

TL;DR: In this article, a wearable monitor that includes two components, a flexible extended wear electrode patch and a removable monitor recorder, sits centrally on the patient's chest along the sternum oriented top-to-bottom.
References
More filters
Journal ArticleDOI

Ambulatory Arrhythmia Monitoring Choosing the Right Device

TL;DR: This review focuses on the available technology and factors that guide the choice of monitor, including ambulatory external monitors, implantable event recorders, pacemakers, and cardioverter-defibrillators.
Journal ArticleDOI

Use of a Noninvasive Continuous Monitoring Device in the Management of Atrial Fibrillation: A Pilot Study

TL;DR: Outpatient ambulatory cardiac rhythm monitoring is a routine part of the management of patients with paroxysmal atrial fibrillation and is limited by patient convenience and practicality.
Journal ArticleDOI

Ambulatory external electrocardiographic monitoring: focus on atrial fibrillation.

TL;DR: Ambulatory external electrocardiogram monitoring technology plays an important role in patients with known AF to guide ventricular rate control and anticoagulation therapy, and assess the efficacy of antiarrhythmic drug therapy and/or ablation procedures.
Journal ArticleDOI

Best electrode locations for a small bipolar ECG device: signal strength analysis of clinical data.

TL;DR: The results showed that deviation in signal amplitude between different subjects is significant, however, judging from average values, the best orientation for a closely located bipolar electrode pair is diagonally on the chest.
Journal ArticleDOI

A user-friendly integrated monitor-adhesive patch for long-term ambulatory electrocardiogram monitoring.

TL;DR: An integrated adhesive monitor that can be worn on the skin up to 7 days with minimal side effects is feasible and patients considered the device comfortable.
Related Papers (5)