scispace - formally typeset
Journal ArticleDOI

New focused ultrasound transducer for fat cell disruption

Reads0
Chats0
TLDR
In this article, the authors modified the transducer design in order to solve the overheating problem and simulated the performance of the modified transducers by finite element analysis and fabricated the newly designed transducers, which can effectively reduce temperature rise while keeping the acoustic intensity field unaffected.
Abstract
Being an emerging body-shaping technology of fat cell disruption, high-intensity focused ultrasound has been investigated intensively in recent years for its favorable natures such as painlessness, safety and noninvasion. One of the major problems for the technology, however, is the overheating of transducers. In this study, we modified the transducer design in order to solve the overheating problem. We simulated the performance of the modified design by finite element analysis and fabricated the newly designed transducer. By measuring the actual performance data, we proved that the new design can effectively reduce temperature rise while keeping the acoustic intensity field unaffected.

read more

Citations
More filters
Journal ArticleDOI

Review on triggered liposomal drug delivery with a focus on ultrasound.

TL;DR: This review focuses on liposome-based drug delivery systems, using different trigger mechanisms, with a focus on ultrasound, and the physical mechanisms of ultrasound release are investigated.
Dissertation

Liposomal drug release using ultrasound and modeling release dynamics for model predictive controller design

TL;DR: A Master of Science thesis in Electrical Engineering by Hesham Gamal Moussa as mentioned in this paper used ultrasound and modeling release dynamics for model predictive controller design, which was submitted in June 2015.
References
More filters
Journal ArticleDOI

Noninvasive body contouring by focused ultrasound: safety and efficacy of the Contour I device in a multicenter, controlled, clinical study.

TL;DR: The Contour I device provides a safe and effective noninvasive technology for body contouring and produced a mean reduction of approximately 2 cm in treatment area circumference and approximately 2.9 mm in skin fat thickness.
Proceedings ArticleDOI

The feasibility of tissue ablation using high intensity electronically focused ultrasound

TL;DR: In this paper, the authors demonstrate the feasibility of an annular array treatment system which uses high intensity electronically focused ultrasound using computer simulations to design the system required for the treatment and demonstrate that the shape of the treated region can be well controlled as predicted by theoretical analysis.
Related Papers (5)