scispace - formally typeset
Open AccessJournal ArticleDOI

Telemonitoring Techniques for Lung Volume Measurement: Accuracy, Artifacts and Effort.

Reads0
Chats0
TLDR
This review proves for an in-depth explanation of four (potential) telemonitoring systems in terms of work principle, accuracy, disturbing factors and usability and can be used to select the optimal technique for a specific purpose in future studies.
Abstract
Telemonitoring becomes more important in pulmonary research. It can be used to decrease the pressure on the health care system, to lower the costs of health care and to increase quality of life of patients. Previous studies show contradictory results regarding the effectiveness of telemonitoring. According to multiple researchers, inefficiency can be a result of poor study design, low data quality and usability issues. To counteract these issues, this review proves for an in-depth explanation of four (potential) telemonitoring systems in terms of work principle, accuracy, disturbing factors and usability. The evaluated systems are portable spirometry/breath-by-breath analyzers, respiratory inductance and magnetic plethysmography and electrical impedance tomography. These insights can be used to select the optimal technique for a specific purpose in future studies.

read more

Content maybe subject to copyright    Report

Citations
More filters
Patent

A portable device

TL;DR: The person (1) is warned by means of the vibration generator before a determined by the evaluation device in conjunction with the positioning system and with the communication device dangerous situation, which is a collision of the person carrying the portable device with the at least one external system, which has at least two further communications device.
Journal ArticleDOI

A meta-learning algorithm for respiratory flow prediction from FBG-based wearables in unrestrained conditions

TL;DR: A meta-learning algorithm based on LSTM neural networks for inferring the respiratory flow from a wearable system embedding FBG sensors and inertial units is presented in this article . But, the meta learning algorithm is not suitable for new subjects.
Proceedings ArticleDOI

A Quantitative Approach and Preliminary Application in Healthy Subjects and Patients with Valvular Heart Disease for 24-h Breathing Patterns Analysis Using Wearable Devices

TL;DR: In this paper , a reference approach including signal quality assessment, calibration of tidal volume, and breathing patterns parameters based on a wearable continuous physiological parameter monitoring system for 24-h breathing patterns analysis, including time domain, frequency domain and nonlinear domain.
Journal ArticleDOI

Cardiorespiratory Assessments in Panic Disorder Facilitated by Wearable Devices: A Systematic Review and Brief Comparison of the Wearable Zephyr BioPatch with the Quark-b2 Stationary Testing System

TL;DR: In this paper , the authors systematically reviewed the evidence for wearables-based cardiorespiratory assessments in patients with panic disorder by searching for publications on the PubMed, PsycINFO, and Embase databases, from inception to 30 July 2022.
References
More filters
Journal ArticleDOI

Systematic Review: Process of Forming Academic Service Partnerships to Reform Clinical Education

TL;DR: This study’s findings can provide practical guidelines to steer partnership programs within the academic and clinical bodies, with the aim of providing a collaborative partnership approach to clinical education.
Journal ArticleDOI

Standardisation of spirometry

TL;DR: This research presents a novel and scalable approach called “Standardation of LUNG FUNCTION TESTing” that combines “situational awareness” and “machine learning” to solve the challenge of integrating nanofiltration into the energy system.
Journal ArticleDOI

Standardisation of the measurement of lung volumes

TL;DR: This research presents a novel and scalable approach called “Standardation of LUNG FUNCTION TESTing” that combines “situational awareness” and “machine learning” to solve the challenge of integrating nanofiltration into the energy system.
Journal ArticleDOI

Electrical Impedance Tomography

TL;DR: A survey of the work in electrical impedance tomography can be found in this article, where the authors survey some of the most important works in the field. Butt.t.