Thin-film microbiosensors for glucose-lactate monitoring

Reads0
Chats0
TLDR
A miniaturized device for simultaneous measurement of glucose and lactate levels was produced by means of photopatterning of enzyme-containing photosensitive membrane precursors and subcutaneous measurements of glucose levels in pigs were close to the corresponding blood levels obtained without in vivo calibration.
Abstract
A miniaturized device for simultaneous measurement of glucose and lactate levels was produced by means of photopatterning of enzyme-containing photosensitive membrane precursors. This device shows no cross-talk and a lifetime for both the glucose and the lactate sensors of more than 2 weeks when continuously operated in undiluted bovine serum. Linear response ranges of up to 40 mM for glucose and 25 mM for l-lactate, in combination with 95% response times of 0.98 with respect to laboratory techniques. Subcutaneous measurements of glucose levels in pigs were close to the corresponding blood levels obtained without in vivo calibration.

read more

Citations
More filters
Journal ArticleDOI

Hydrogels in Biology and Medicine: From Molecular Principles to Bionanotechnology†

TL;DR: This work highlights recent developments in engineering uncrosslinked and crosslinked hydrophilic polymers for biomedical and biological applications and shows how such systems' intelligent behavior can be used in sensors, microarrays, and imaging.
Journal ArticleDOI

Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis

TL;DR: This work bridges the technological gap between signal transduction, conditioning, processing and wireless transmission in wearable biosensors by merging plastic-based sensors that interface with the skin with silicon integrated circuits consolidated on a flexible circuit board for complex signal processing.
Patent

Analyte Monitoring Device And Methods Of Use

TL;DR: An analyte monitor includes a sensor, a sensor control unit, and a display unit as discussed by the authors, which is used to display an indication of a level of an analyte, based on the data obtained using the sensor.
Patent

Transcutaneous analyte sensor

TL;DR: In this paper, the present paper relates to systems and methods for transcutaneous measurement of glucose in a host, and the present invention relates to the system and method for measuring an analyte in the host.
Patent

Subcutaneous glucose electrode

TL;DR: In this article, a small diameter flexible electrode designed for subcutaneous in vivo amperometric monitoring of glucose is described, which is designed to allow "one-point" in vivo calibration, i.e., to have zero output current at zero glucose concentration, even in the presence of other electroreactive species of serum or blood.
References
More filters
Journal ArticleDOI

Cortical evoked potential and extracellular K+ and H+ at critical levels of brain ischemia.

TL;DR: The hypothesis that electrical failure in ischemia may be directly associated with a massive release of intracellular K+ or with a critical degree of extracellular acidosis is tested and the concept of an ischemic penumbra during which the neurons remain structurally intact but functionally inactive is supported.
Journal ArticleDOI

Performance of subcutaneously implanted needle-type glucose sensors employing a novel trilayer coating

TL;DR: A miniature, needle-type glucose sensor based on a new trilayer membrane configuration has been prepared and evaluated both in vitro and in vivo, and remained functional after 1 week of implantation, but failed after 2 weeks due to degradation of the reference electrode.
Journal ArticleDOI

Evaluation of a novel point-of-care system, the i-STAT portable clinical analyzer.

TL;DR: The i-STAT Portable Clinical Analyzer system was evaluated for precision, accuracy, and utility in emergency department and stat laboratory settings and mean hematocrit values significantly differed between the PCA and the Coulter ST, apparently because of different calibration procedures.
Journal ArticleDOI

Towards continuous glucose monitoring in vivo evaluation of a miniaturized glucose sensor implanted for several days in rat subcutaneous tissue

TL;DR: It is concluded that this miniaturized glucose sensor, whose size makes it easily implanted, works for at least ten days after implantation into rat subcutaneous tissue.