scispace - formally typeset
Search or ask a question

Showing papers in "arXiv: Instrumentation and Detectors in 2008"


Journal ArticleDOI
TL;DR: In this article, a photon number-resolving detector based on a four-element superconducting nanowire single photon detector is demonstrated to have sub-30-ps resolution in measuring the arrival time of individual photons.
Abstract: A photon-number-resolving detector based on a four-element superconducting nanowire single photon detector is demonstrated to have sub-30-ps resolution in measuring the arrival time of individual photons. This detector can be used to characterize the photon statistics of non-pulsed light sources and to mitigate dead-time effects in high-speed photon counting applications. Furthermore, a 25% system detection efficiency at 1550 nm was demonstrated, making the detector useful for both low-flux source characterization and high-speed photon-counting and quantum communication applications. The design, fabrication and testing of this detector are described, and a comparison between the measured and theoretical performance is presented.

122 citations


Journal ArticleDOI
TL;DR: In this article, a new approach based on the domain wall displacement in confined ferromagnetic nanostructures for attracting and sensing a single nanometric magnetic particles is presented, which can be suitable to biomolecular recognition, and in particular to single molecule detection.
Abstract: A new approach based on the domain wall displacement in confined ferromagnetic nanostructures for attracting and sensing a single nanometric magnetic particles is presented. We modeled and experimentally demonstrated the viability of the approach using an anisotropic magnetoresistance device made by a micron-size square ring of Permalloy designed for application in magnetic storage. This detection concept can be suitable to biomolecular recognition, and in particular to single molecule detection.

56 citations


Journal ArticleDOI
TL;DR: In this paper, a new type of radiation detector based on a spherical geometry is presented, which consists of a large spherical gas volume with a central electrode forming a radial electric field, where charges deposited in the conversion volume drift to the central sensor where they are amplified and collected.
Abstract: A new type of radiation detector based on a spherical geometry is presented. The detector consists of a large spherical gas volume with a central electrode forming a radial electric field. Charges deposited in the conversion volume drift to the central sensor where they are amplified and collected. We introduce a small spherical sensor located at the center acting as a proportional amplification structure. It allows high gas gains to be reached and operates in a wide range of gas pressures. Signal development and the absolute amplitude of the response are consistent with predictions. Sub-keV energy threshold with good energy resolution is achieved. This new concept has been proven to operate in a simple and robust way and allows reading large volumes with a single read-out channel. The detector performance presently achieved is already close to fulfill the demands of many challenging projects from low energy neutrino physics to dark matter detection with applications in neutron, alpha and gamma spectroscopy.

52 citations


Posted Content
TL;DR: In this paper, a quadruple well process developed in a modern 0.18mu CMOS technology called INMAPS was used to prevent the collection of radiation induced charge by unrelated N-wells, typically ones where PMOS transistors are integrated.
Abstract: In this paper we present a novel, quadruple well process developed in a modern 0.18mu CMOS technology called INMAPS. On top of the standard process, we have added a deep P implant that can be used to form a deep P-well and provide screening of N-wells from the P-doped epitaxial layer. This prevents the collection of radiation-induced charge by unrelated N-wells, typically ones where PMOS transistors are integrated. The design of a sensor specifically tailored to a particle physics experiment is presented, where each 50mu pixel has over 150 PMOS and NMOS transistors. The sensor has been fabricated in the INMAPS process and first experimental evidence of the effectiveness of this process on charge collection is presented, showing a significant improvement in efficiency.

50 citations


Journal ArticleDOI
TL;DR: In this article, the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors has been studied and a physics prototype has been constructed, consisting of thirty sensitive layers, each layer has an active area of 18x18 cm2 and a pad size of 1x1 cm2.
Abstract: The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high granularity sampling calorimeter with tungsten as absorber and silicon detectors as sensitive material. A ``physics prototype'' has been constructed, consisting of thirty sensitive layers. Each layer has an active area of 18x18 cm2 and a pad size of 1x1 cm2. The absorber thickness totals 24 radiation lengths. It has been exposed in 2006 and 2007 to electron and hadron beams at the DESY and CERN beam test facilities, using a wide range of beam energies and incidence angles. In this paper, the prototype and the data acquisition chain are described and a summary of the data taken in the 2006 beam tests is presented. The methods used to subtract the pedestals and calibrate the detector are detailed. The signal-over-noise ratio has been measured at 7.63 +/- 0.01. Some electronics features have been observed; these lead to coherent noise and crosstalk between pads, and also crosstalk between sensitive and passive areas. The performance achieved in terms of uniformity and stability is presented.

49 citations


Journal ArticleDOI
TL;DR: In this article, the authors proposed to use compact micro-pattern gas detectors, such as Gas Electron Multipliers (GEMs), for muon tomography for detecting high-Z materials.
Abstract: Muon Tomography (MT) based on the measurement of multiple scattering of atmospheric cosmic ray muons traversing shipping containers is a promising candidate for identifying threatening high-Z materials. Since position-sensitive detectors with high spatial resolution should be particularly suited for tracking muons in an MT application, we propose to use compact micro-pattern gas detectors, such as Gas Electron Multipliers (GEMs), for muon tomography. We present a detailed GEANT4 simulation of a GEM-based MT station for various scenarios of threat material detection. Cosmic ray muon tracks crossing the material are reconstructed with a Point-Of-Closest-Approach algorithm to form 3D tomographic images of the target material. We investigate acceptance, Z-discrimination capability, effects of placement of high-Z material and shielding materials inside the cargo, and detector resolution effects for such a MT station.

46 citations


Journal ArticleDOI
TL;DR: The PICASSO collaboration observed for the first time a significant difference between the acoustic signals induced by neutrons and alpha particles in a detector based on superheated liquids, which offers the possibility of improved background suppression and could be especially useful for dark matter experiments as discussed by the authors.
Abstract: The PICASSO collaboration observed for the first time a significant difference between the acoustic signals induced by neutrons and alpha particles in a detector based on superheated liquids. This new discovery offers the possibility of improved background suppression and could be especially useful for dark matter experiments. This new effect may be attributed to the formation of multiple bubbles on alpha tracks, compared to single nucleations created by neutron induced recoils.

45 citations


Journal ArticleDOI
TL;DR: Two simple cryogenic rf ion trap systems in which cryogenic temperatures and ultra high vacuum pressures can be reached in as little as 12 h are presented.
Abstract: We present two simple cryogenic RF ion trap systems in which cryogenic temperatures and ultra high vacuum pressures can be reached in as little as 12 hours. The ion traps are operated either in a liquid helium bath cryostat or in a low vibration closed cycle cryostat. The fast turn around time and availability of buffer gas cooling made the systems ideal for testing surface-electrode ion traps. The vibration amplitude of the closed cycled cryostat was found to be below 106 nm. We evaluated the systems by loading surface-electrode ion traps with $^{88}$Sr$^+$ ions using laser ablation, which is compatible with the cryogenic environment. Using Doppler cooling we observed small ion crystals in which optically resolved ions have a trapped lifetime over 2500 minutes.

44 citations


Journal ArticleDOI
TL;DR: In this paper, a new method for efficient and unambiguous interconnection between electronic counters and target units based on nuclear photographic emulsion films has been developed for the OPERA experiment.
Abstract: New methods for efficient and unambiguous interconnection between electronic counters and target units based on nuclear photographic emulsion films have been developed. The application to the OPERA experiment, that aims at detecting oscillations between mu neutrino and tau neutrino in the CNGS neutrino beam, is reported in this paper. In order to reduce background due to latent tracks collected before installation in the detector, on-site large-scale treatments of the emulsions ("refreshing") have been applied. Changeable Sheet (CSd) packages, each made of a doublet of emulsion films, have been designed, assembled and coupled to the OPERA target units ("ECC bricks"). A device has been built to print X-ray spots for accurate interconnection both within the CSd and between the CSd and the related ECC brick. Sample emulsion films have been extensively scanned with state-of-the-art automated optical microscopes. Efficient track-matching and powerful background rejection have been achieved in tests with electronically tagged penetrating muons. Further improvement of in-doublet film alignment was obtained by matching the pattern of low-energy electron tracks. The commissioning of the overall OPERA alignment procedure is in progress.

42 citations


Posted Content
TL;DR: In this article, a double-stage Large Electron Multiplier (LEM) readout system was used for time projection in a liquid-vapour (double) phase pure Ar.
Abstract: We successfully operated a novel kind of LAr Time Projection Chamber based on a Large Electron Multiplier (LEM) readout system. The prototype, of about 3 liters active volume, is operated in liquid-vapour (double) phase pure Ar. The ionization electrons, after drifting in the LAr volume, are extracted by a set of grids into the gas phase and driven into the holes of a double stage LEM, where charge amplification occurs. Each LEM is a thick macroscopic hole multiplier of 10x10 cm$^2$ manufactured with standard PCB techniques. The electrons signal is readout via two orthogonal coordinates, one using the induced signal on the segmented upper electrode of the LEM itself and the other by collecting the electrons on a segmented anode. Custom-made preamplifiers have been especially developed for this purpose. Cosmic ray tracks have been successfully observed in pure gas at room temperature and in double phase Ar operation. We believe that this proof of principle represents an important milestone in the realization of very large, long drift (cost-effective) LAr detectors for next generation neutrino physics and proton decay experiments, as well as for direct search of Dark Matter with imaging devices.

37 citations


Journal ArticleDOI
TL;DR: In this article, the performance of thick GEMs (THGEMs) was compared to that of thin GEM (GEM) in two-phase Ar avalanche detectors, in view of their potential application in coherent neutrino-nucleus scattering, dark-matter search and in other rare event experiments.
Abstract: The performance of thick GEMs (THGEMs) was compared to that of thin GEMs in two-phase Ar avalanche detectors, in view of their potential application in coherent neutrino-nucleus scattering, dark-matter search and in other rare-event experiments. The detectors comprised a 1 cm thick liquid-Ar layer followed by either a double-THGEM or a triple-GEM multiplier, operated in the saturated vapor above the liquid phase. Three types of THGEMs were studied: those made of G10 and Kevlar and that with resistive electrodes (RETHGEM). Only the G10-made THGEM showed a stable performance in two-phase Ar with gains reaching 3000. Successful operation of two-phase Ar avalanche detectors with either thin- or thick-GEM multipliers was demonstrated at low detection thresholds, of 4 and 20 primary electrons respectively. Compared to the triple-GEM the double-THGEM multiplier yielded slower anode signals; this allowed applying a pulse-shape analysis to effectively reject noise signals. Noise rates of both multipliers were evaluated in two-phase Ar; with detection thresholds of 20 electrons and applying pulse-shape analysis noise levels as low as 0.007 Hz per 1 cm2 of active area were reached.

Posted Content
W. Erni, I. Keshelashvili, B. Krusche, M. Steinacher  +404 moreInstitutions (4)
TL;DR: In this article, the authors present the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer.
Abstract: This document presents the technical layout and the envisaged performance of the Electromagnetic Calorimeter (EMC) for the PANDA target spectrometer. The EMC has been designed to meet the physics goals of the PANDA experiment, which is being developed for the Facility for Antiproton and Ion Research (FAIR) at Darmstadt, Germany. The performance figures are based on extensive prototype tests and radiation hardness studies. The document shows that the EMC is ready for construction up to the front-end electronics interface.

Journal ArticleDOI
TL;DR: A low-noise, high modulation-bandwidth design for a laser current driver with excellent long-term stability, and a thorough characterization of its stability, noise, set-point accuracy and repeatability, temperature dependence, transient response, and modulation bandwidth.
Abstract: We present a low-noise, high modulation-bandwidth design for a laser current driver with excellent long term stability. The driver improves upon the commonly-used Hall-Libbrecht design. The current driver can be operated remotely by way of a micro-processing unit, which controls the current set point digitally. This allows precise repeatability and improved accuracy and stability. It also allows the driver to be placed near the laser for reduced noise and for lower phase lag when using the modulation input. We present the theory of operation for our driver in detail, and give a thorough characterization of its stability, noise, set point accuracy and repeatability, temperature dependence, transient response, and modulation bandwidth.

Journal ArticleDOI
TL;DR: In this article, the quenching factor of a 5 cm diameter NaI(Tl) crystal at room temperature has been measured at a dedicated neutron facility at the University of Sheffield.
Abstract: Measurements of the quenching factor for sodium recoils in a 5 cm diameter NaI(Tl) crystal at room temperature have been made at a dedicated neutron facility at the University of Sheffield. The crystal has been exposed to 2.45 MeV mono-energetic neutrons generated by a Sodern GENIE 16 neutron generator, yielding nuclear recoils of energies between 10 and 100 keVnr. A cylindrical BC501A detector has been used to tag neutrons that scatter off sodium nuclei in the crystal. Cuts on pulse shape and time of flight have been performed on pulses recorded by an Acqiris DC265 digitiser with a 2 ns sampling time. Measured quenching factors of Na nuclei range from 19% to 26% in good agreement with other experiments, and a value of 25.2 \pm 6.4% has been determined for 10 keV sodium recoils. From pulse shape analysis, the mean times of pulses from electron and nuclear recoils have been compared down to 2 keVee. The experimental results are compared to those predicted by Lindhard theory, simulated by the SRIM Monte Carlo code, and a preliminary curve calculated by Prof. Akira Hitachi.

Posted Content
TL;DR: In this article, the setup of two low-level gamma-spectroscopy spectrometers is described, and the applied techniques to meet the respective needs are discussed and demonstrated by experimental results.
Abstract: The previous article about material screening for GERDA points out the importance of strict material screening and selection for radioimpurities as a key to meet the aspired background levels of the GERDA experiment. This is directly done using low-level gamma-spectroscopy. In order to provide sufficient selective power in the mBq/kg range and below, the employed gamma-spectrometers themselves have to meet strict material requirements, and make use of an elaborate shielding system. This article gives an account of the setup of two such spectrometers. Corrado is located in a depth of 15 m w.e. at the MPI-K in Heidelberg (Germany), GeMPI III is situated at the Gran-Sasso underground laboratory at 3500 m w.e. (Italy). The latter one aims at detecting sample activities of the order ~0.01 mBq/kg, which is the current state-of-the-art level. The applied techniques to meet the respective needs are discussed and demonstrated by experimental results.

Journal ArticleDOI
TL;DR: In this paper, 3D silicon detectors with cylindrical electrodes perpendicular to the surface and penetrating into the bulk material are characterized by 3D Si detectors with planar electrodes on its top and bottom, which render them particularly interesting to be used in environments where standard Si detectors have limitations, such as the radiation environment expected in an LHC upgrade.
Abstract: 3D silicon detectors are characterized by cylindrical electrodes perpendicular to the surface and penetrating into the bulk material in contrast to standard Si detectors with planar electrodes on its top and bottom. This geometry renders them particularly interesting to be used in environments where standard silicon detectors have limitations, such as for example the radiation environment expected in an LHC upgrade. For the first time, several 3D sensors were assembled as hybrid pixel detectors using the ATLAS-pixel front-end chip and readout electronics. Devices with different electrode configurations have been characterized in a 100 GeV pion beam at the CERN SPS. Here we report results on unirradiated devices with three 3D electrodes per 50 x 400 um2 pixel area. Full charge collection is obtained already with comparatively low bias voltages around 10 V. Spatial resolution with binary readout is obtained as expected from the cell dimensions. Efficiencies of 95.9% +- 0.1 % for tracks parallel to the electrodes and of 99.9% +- 0.1 % at 15 degrees are measured. The homogeneity of the efficiency over the pixel area and charge sharing are characterized.

Journal ArticleDOI
TL;DR: In this article, the authors proposed an almost parasitic implementation of an external magnetic field along the arms of the VIRGO interferometer and discussed the advantage of this choice in comparison to a previously proposed configuration based on shorter prototype interferometers which they believe is inadequate.
Abstract: Low energy non linear QED effects in vacuum have been predicted since 1936 and have been subject of research for many decades. Two main schemes have been proposed for such a 'first' detection: measurements of ellipticity acquired by a linearly polarized beam of light passing through a magnetic field and direct light-light scattering. The study of the propagation of light through an external field can also be used to probe for new physics such as the existence of axion-like particles and millicharged particles. Their existence in nature would cause the index of refraction of vacuum to be different from unity in the presence of an external field and dependent of the polarization direction of the light propagating. The major achievement of reaching the project sensitivities in gravitational wave interferometers such as LIGO an VIRGO has opened the possibility of using such instruments for the detection of QED corrections in electrodynamics and for probing new physics at very low energies. In this paper we discuss the difference between direct birefringence measurements and index of refraction measurements. We propose an almost parasitic implementation of an external magnetic field along the arms of the VIRGO interferometer and discuss the advantage of this choice in comparison to a previously proposed configuration based on shorter prototype interferometers which we believe is inadequate. Considering the design sensitivity in the strain, for the near future VIRGO+ interferometer, of $h<2\cdot10^{-23} \frac{1}{\sqrt{\rm Hz}}$ in the range 40 Hz $- 400$ Hz leads to a variable dipole magnet configuration at a frequency above 20 Hz such that $B^{2}D \ge 13000$ T$^{2}$m/$\sqrt{\rm Hz}$ for a `first' vacuum non linear QED detection.

Posted Content
TL;DR: The ATLAS detector at CERN's Large Hadron Collider (LHC) is equipped with a tracking system at its core (the Inner Detector, ID) consisting of silicon and gaseous straw tube detectors as mentioned in this paper.
Abstract: The ATLAS detector at CERN's Large Hadron Collider (LHC) is equipped with a tracking system at its core (the Inner Detector, ID) consisting of silicon and gaseous straw tube detectors. The physics performance of the ID requires a precision alignment; a challenge involving complex algorithms and significant computing power. The alignment algorithms were already validated on: Combined Test Beam data, Cosmic Ray runs and simulated physics events. The alignment chain was tested on a daily basis in exercises that mimicked ATLAS data taking operations. ID commissioning after final installation into the ATLAS detector has yielded thousands of reconstructed cosmic ray tracks, which have been used for an initial alignment of the ID before the LHC start-up. A hardware system using Frequency Scanning Interferometry will be used to monitor structural deformations. Given the programme outlined here, the ATLAS Inner Detector has had a solid preparation for LHC collisions.

Journal ArticleDOI
TL;DR: A technique for determining the permeability of a phospholipid membrane on a single giant unilamellar vesicle (GUV) is described, which complements the existing methods utilizing either a planar black lipid membrane or sub-micrometre-sized liposomes.
Abstract: A technique for determining the permeability of a phospholipid membrane on a single giant unilamellar vesicle (GUV) is described, which complements the existing methods utilizing either a planar black lipid membrane or sub-micrometre-sized liposomes. A single GUV is transferred using a micropipette from a solution of a nonpermeable solute into an iso-osmolar solution of a solute with a higher membrane permeability. Osmotical swelling of the vesicle is monitored with a CCD camera mounted on a phase contrast microscope, and a sequence of images is obtained. On each image, the points on the vesicle contour are determined using Sobel filtering with adaptive binarization threshold, and from these, the vesicle radius is calculated with a great accuracy. From the time-dependence of the vesicle radius, the membrane permeability is obtained. Using a test set of data, the method provided a consistent estimate of the POPC membrane permeability for glycerol, P = 1.7 x 10^-8 m/s, with individual samples ranging from 1.61 x 10^-8 m/s to 1.98 x 10^-8 m/s. This value is ~40% lower than the one obtained on similar systems. Possible causes for this discrepancy are discussed.

Journal ArticleDOI
TL;DR: A 1 km-3 neutrino detector named IceCube is currently 50% complete at the Amundsen-Scott South Pole Station as discussed by the authors, where it consists of 4800 Digital Optical Modules (DOMs) which detect Cherenkov radiation from the charged particles produced in neutrinos interactions.
Abstract: IceCube is a 1 km^3 neutrino detector now being built at the Amundsen-Scott South Pole Station. It consists of 4800 Digital Optical Modules (DOMs) which detect Cherenkov radiation from the charged particles produced in neutrino interactions. IceCube will observe astrophysical neutrinos with energies above about 100 GeV. IceCube will be able to separate u_\mu, u_e and u_\tau interactions because of their different topologies. IceCube construction is currently 50% complete.

Journal ArticleDOI
TL;DR: In this article, the performance and chemical and physical properties of a 2 x 1.2 ton organic liquid scintillator target doped with Gd up to 0.1% were reported.
Abstract: In this work we report the performances and the chemical and physical properties of a (2 x 1.2) ton organic liquid scintillator target doped with Gd up to ~0.1%, and the results of a 2 year long stability survey. In particular we have monitored the amount of both Gd and primary fluor actually in solution, the optical and fluorescent properties of the Gd-doped liquid scintillator (GdLS) and its performances as a neutron detector, namely neutron capture efficiency and average capture time. The experimental survey is ongoing, the target being continuously monitored. After two years from the doping time the performances of the Gd-doped liquid scintillator do not show any hint of degradation and instability; this conclusion comes both from the laboratory measurements and from the "in-tank" measurements. This is the largest stable Gd-doped organic liquid scintillator target ever produced and continuously operated for a long period.

Journal ArticleDOI
TL;DR: In this article, the expected performance of track reconstruction with LHC events using the CMS silicon tracker is presented, and track finding and fitting is accomplished with Kalman Filter techniques that achieve efficiencies above 99% on single muons with pT>1 GeV/c.
Abstract: The expected performance of track reconstruction with LHC events using the CMS silicon tracker is presented. Track finding and fitting is accomplished with Kalman Filter techniques that achieve efficiencies above 99% on single muons with pT>1 GeV/c. Difficulties arise in the context of standard LHC events with a high density of charged particles, where the rate of fake combinatorial tracks is very large for low pT tracks, and nuclear interactions in the tracker material reduce the tracking efficiency for charged hadrons. Recent improvements with the CMS track reconstruction now allow to efficiently reconstruct charged tracks with pT down to few hundred MeV/c and as few as three crossed layers, with a very small fake fraction, by making use of an optimal rejection of fake tracks in conjunction with an iterative tracking procedure.

Journal ArticleDOI
TL;DR: In this paper, the authors report on the evidence for ionization track signals from cosmic ray muons and Compton electrons in a Time Projection Chamber (TPC) filled with liquid Argon and doped with different fractions of Nitrogen.
Abstract: In this paper we report on the evidence for ionization track signals from cosmic ray muons and Compton electrons in a Time Projection Chamber (TPC) filled with liquid Argon and doped with different fractions of Nitrogen. This study has been conducted in view of the possible use of liquid Argon/Nitrogen TPCs for the detection of gamma rays in the resonant band of the Nitrogen absorbtion spectrum, a promising technology for security and medical applications.

Journal ArticleDOI
TL;DR: The detector for imaging of explosions (DIMEX) has been in operation at the synchrotron radiation (SR) beam-line at VEPP-3 electron ring at Budker INP since 2002.
Abstract: The detector for imaging of explosions (DIMEX) is in operation at the synchrotron radiation (SR) beam-line at VEPP-3 electron ring at Budker INP since 2002. DIMEX is based on one-coordinate gas ionization chamber filled with Xe-CO2(3:1) mixture at 7atm, and active Frisch-grid made of Gas Electron Multiplier (GEM). The detector has spatial resolution of ~0.2mm and dynamic range of ~100 that allows to realize the precision of signal measurement at a percent level. The frame rate can be tuned up to 8 MHz (125 ns per image) and up to 32 images can be stored in one shot. At present DIMEX is used with the X-ray beam from 2T wiggler that has ~20 keV average energy. Future possibility to install similar detector at the SR beam-line at VEPP-4 electron ring is discussed.

Journal ArticleDOI
TL;DR: A circuit capable of measuring nanoampere currents while floating at voltages up to at least 25kV is described, which allows robust operation in the presence of high voltage spikes and discharges.
Abstract: A circuit capable of measuring nanoampere currents while floating at voltages up to at least 25kV is described. The circuit relays its output to ground potential via an optical fiber. We particularly emphasize the design and construction techniques which allow robust operation in the presence of high voltage spikes and discharges.

Journal ArticleDOI
TL;DR: In this paper, an electrostatic field evaporation based deuterium ion source was demonstrated for use in compact, high-output DEUTERIUM-tritium neutron generators.
Abstract: Proof-of-principle experiments have demonstrated an electrostatic field evaporation based deuterium ion source for use in compact, high-output deuterium-tritium neutron generators The ion source produces principally atomic deuterium and titanium ions More than 100 monolayers of deuterated titanium thin film can be removed and ionized from a single tip in less than 20 ns The measurements indicate that with the use of microfabricated tip arrays the deuterium ion source could provide sufficient ion current to produce 10^9 to 10^10 n/cm^2 of tip array area

Proceedings ArticleDOI
TL;DR: The neutral sensor ELENA (Emitted Low-Energy Neutral Atoms) for the ESA cornerstone BepiColombo mission to Mercury (in the SERENA instrument package) is a new kind of low energetic neutral atoms instrument, mostly devoted to sputtering emission from planetary surfaces, from E ~20 eV up to E~5 keV, within 1-D (2x76 deg) as mentioned in this paper.
Abstract: The neutral sensor ELENA (Emitted Low-Energy Neutral Atoms) for the ESA cornerstone BepiColombo mission to Mercury (in the SERENA instrument package) is a new kind of low energetic neutral atoms instrument, mostly devoted to sputtering emission from planetary surfaces, from E ~20 eV up to E~5 keV, within 1-D (2x76 deg). ELENA is a Time-of-Flight (TOF) system, based on oscillating shutter (operated at frequencies up to a 100 kHz) and mechanical gratings: the incoming neutral particles directly impinge upon the entrance with a definite timing (START) and arrive to a STOP detector after a flight path. After a brief dissertation on the achievable scientific objectives, this paper describes the instrument, with the new design techniques approached for the neutral particles identification and the nano-techniques used for designing and manufacturing the nano-structure shuttering core of the ELENA sensor. The expected count-rates, based on the Hermean environment features, are shortly presented and discussed. Such design technologies could be fruitfully exported to different applications for planetary exploration.

Journal ArticleDOI
TL;DR: In this article, the authors analyzed in detail, using Monte-Carlo calculations and experimentally determined parameters, all the processes that influence the signal and noise in the TRION detector and showed that even under ideal light collection conditions, a fast neutron detection system operating in an integrative mode cannot be quantum-noise-limited due to the relatively large variance in the imparted energy and the resulting scintillation light distributions.
Abstract: TRION is a sub-mm spatial resolution fast neutron imaging detector, which employs an integrative optical time-of-flight technique The detector was developed for fast neutron resonance radiography, a method capable of detecting a broad range of conventional and improvised explosives In this study we have analyzed in detail, using Monte-Carlo calculations and experimentally determined parameters, all the processes that influence the signal and noise in the TRION detector In contrast to event-counting detectors where the signal-to-noise ratio is dependent only on the number of detected events (quantum noise), in an energy-integrating detector additional factors, such as the fluctuations in imparted energy, number of photoelectrons, system gain and other factors will contribute to the noise The excess noise factor (over the quantum noise) due to these processes was 43, 27, 21, 19 and 19 for incident neutron energies of 2, 4, 75, 10 and 14 MeV, respectively It is shown that, even under ideal light collection conditions, a fast neutron detection system operating in an integrative mode cannot be quantum-noise-limited due to the relatively large variance in the imparted proton energy and the resulting scintillation light distributions

Journal ArticleDOI
TL;DR: In this article, the results from the gas gain monitoring (GGM) system for the muon detector using RPC in the CMS experiment at the LHC are presented, which is designed to provide fast and accurate determination of any shift in the working point of the chambers due to gas mixture changes.
Abstract: Results from the gas gain monitoring (GGM) system for the muon detector using RPC in the CMS experiment at the LHC is presented. The system is designed to provide fast and accurate determination of any shift in the working point of the chambers due to gas mixture changes.

Proceedings ArticleDOI
TL;DR: PANIC as mentioned in this paper is a wide-field NIR camera, which is currently under development for the Calar Alto observatory (CAHA) in Spain, using a mosaic of four Hawaii-2RG detectors and covers the spectral range from 0.8-2.5 micron(z to K-band).
Abstract: PANIC is a wide-field NIR camera, which is currently under development for the Calar Alto observatory (CAHA) in Spain. It uses a mosaic of four Hawaii-2RG detectors and covers the spectral range from 0.8-2.5 micron(z to K-band). The field-of-view is 30x30 arcmin. This instrument can be used at the 2.2m telescope (0.45arcsec/pixel, 0.5x0.5 degree FOV) and at the 3.5m telescope (0.23arcsec/pixel, 0.25x0.25 degree FOV). The operating temperature is about 77K, achieved by liquid Nitrogen cooling. The cryogenic optics has three flat folding mirrors with diameters up to 282 mm and nine lenses with diameters between 130 mm and 255 mm. A compact filter unit can carry up to 19 filters distributed over four filter wheels. Narrow band (1%) filters can be used. The instrument has a diameter of 1.1 m and it is about 1 m long. The weight limit of 400 kg at the 2.2m telescope requires a light-weight cryostat design. The aluminium vacuum vessel and radiation shield have wall thicknesses of only 6 mm and 3 mm respectively.