scispace - formally typeset
Open AccessJournal ArticleDOI

4D phase contrast MRI at 3 T: effect of standard and blood-pool contrast agents on SNR, PC-MRA, and blood flow visualization.

Reads0
Chats0
TLDR
In a group of 30 healthy volunteers, the influence of different contrast agents on vascular signal‐to‐noise ratio, PC‐MRA quality, and subsequent three‐dimensional stream‐line visualization in the thoracic aorta was determined.
Abstract
Time-resolved phase contrast (PC) MRI with velocity encoding in three directions (flow-sensitive four-dimensional MRI) can be employed to assess three-dimensional blood flow in the entire aortic lumen within a single measurement. These data can be used not only for the visualization of blood flow but also to derive additional information on vascular geometry with three-dimensional PC MR angiography (MRA). As PC-MRA is sensitive to available signal-to-noise ratio, standard and novel blood pool contrast agents may help to enhance PC-MRA image quality. In a group of 30 healthy volunteers, the influence of different contrast agents on vascular signal-to-noise ratio, PC-MRA quality, and subsequent three-dimensional stream-line visualization in the thoracic aorta was determined. Flow-sensitive four-dimensional MRI data acquired with contrast agent provided significantly improved signal-to-noise ratio in magnitude data and noise reduction in velocity data compared to measurements without contrast media. The agreement of three-dimensional PC-MRA with reference standard contrast-enhanced MRA was good for both contrast agents, with improved PC-MRA performance for blood pool contrast agent, particularly for the smaller supra-aortic branches. For three-dimensional flow visualization, a trend toward improved results for the data with contrast agent was observed.

read more

Citations
More filters
Journal ArticleDOI

4D flow MRI

TL;DR: This review intends to introduce currently used 4D flow MRI methods, including Cartesian and radial data acquisition, approaches for acceleratedData acquisition, cardiac gating, and respiration control, and an overview over the potential this new imaging technique has in different parts of the body from the head to the peripheral arteries.
Journal ArticleDOI

Comprehensive 4D velocity mapping of the heart and great vessels by cardiovascular magnetic resonance

TL;DR: Multidirectional, 3D cine velocity acquisitions are contributing to the understanding of normal and pathologically altered blood flow features, and offers the potential for retrospective quantification of flow and other hemodynamic parameters.
References
More filters
Journal ArticleDOI

Statistical methods for assessing agreement between two methods of clinical measurement.

TL;DR: An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Journal Article

Akufo and ibarapa.

Beckett Ah, +2 more
- 06 Feb 1965 - 
Journal ArticleDOI

Measurement in Medicine: The Analysis of Method Comparison Studies

Douglas G. Altman, +1 more
- 01 Sep 1983 - 
TL;DR: This paper shall describe what is usually done, show why this is inappropriate, suggest a better approach, and ask why such studies are done so badly.
Book ChapterDOI

Properties of Sufficiency and Statistical Tests

TL;DR: In this article, the structure of small sample tests, whether these are related to problems of estimation and fiducial distributions, or are of the nature of tests of goodness of fit, is considered further.
Journal ArticleDOI

The rician distribution of noisy mri data

TL;DR: The image intensity in magnetic resonance magnitude images in the presence of noise is shown to be governed by a Rician distribution and low signal intensities (SNR < 2) are therefore biased due to the noise.
Related Papers (5)