A linear array, scintillation crystal-photodiode detector for megavoltage imaging

Reads0
Chats0
TLDR
In this article, an imaging device was developed to acquire images during external photon-beam radiotherapy treatments, which consists of a linear array of 128 zinc tungstate (ZnWO4) scintillation crystals each of which is individually coupled to a photodiode and associated electronics.
Abstract
An imaging device has been developed to acquire images during external photon-beam radiotherapy treatments. It consists of a linear array of 128 zinc tungstate (ZnWO4) scintillation crystals each of which is individually optically coupled to a photodiode and associated electronics. The image is formed by scanning the linear array across the radiation field using a stepping motor under the control of a microcomputer. Image archive, display, and analysis are performed using a microVAX II computer. Results from a general theoretical analysis are presented before a detailed description of the particular detector construction. The mechanical design of the detector is such that the detector is automatically positioned to within a millimeter relative to the treatment source. This simplifies procedures for analyzing setup variations when comparing a treatment image to any other treatment, or planning, images. Image acquisition takes under 4 s with a contrast resolution of better than 1% at a spatial resolution of 2.5 mm in the object plane. The primary dose used to form these images is 0.55 cGy although the dose received by the patient will be closer to 25 cGy due to the linear scanning geometry and 3.8-s scan time that is used.

read more

Citations
More filters
Journal ArticleDOI

A literature review of electronic portal imaging for radiotherapy dosimetry.

TL;DR: As strategies evolve and commercial products become available, EPID dosimetry has the potential to become an accurate and efficient means of large-scale patient-specific IMRT dose verification for any radiotherapy department.
Journal ArticleDOI

Low-dose megavoltage cone-beam CT for radiation therapy.

TL;DR: The quality of these images, along with the rapid acquisition and reconstruction times, demonstrates that MV CBCT performed by use of a standard linear accelerator equipped with a flat-panel imager can be applied clinically for patient alignment and dose verification purposes.
Journal ArticleDOI

A verification procedure to improve patient set-up accuracy using portal images

TL;DR: The purpose of this study was to establish which level of geometrical accuracy can be obtained during radiotherapy, using portal image analysis, with a minimum number of patient set-up measurements and corrections, using a computer simulation.
Journal ArticleDOI

Megavoltage CT on a tomotherapy system

TL;DR: For expected clinical MVCT doses enough imaging photons are used such that little benefit is conferred by the improved noise model of ML algorithms, and the image quality at those lower doses is not satisfactory for radiotherapy verification.
Journal ArticleDOI

Electronic portal imaging devices: a review and historical perspective of contemporary technologies and research

TL;DR: A review of electronic portal imaging devices used in external beam, megavoltage radiation therapy and a survey of contemporary research efforts focused on improving portal imaging performance by addressing various weaknesses in existing commercial systems is presented.
Related Papers (5)