scispace - formally typeset
Journal ArticleDOI

Advanced static compensator for flexible AC transmission

TLDR
An advanced static VAr compensator capable of operating in all four quadrants of the P-Q plane is presented in this paper, which is realized by combining a GTO-controlled inverter with a battery energy storage system.
Abstract
An advanced static VAr compensator capable of operating in all four quadrants of the P-Q plane is presented. It is realized by combining a GTO-controlled inverter with a battery energy storage system and a GTO-switched damping resistor. A hierarchically structured control system that fully utilizes the capabilities of the compensator to provide reactive power support in steady-state operation and both real and reactive power modulation in the event of power oscillations is developed. Results from simulation studies are presented to demonstrate the effectiveness of this compensator in improving the loadability of long transmission lines and in providing damping in interarea oscillations. >

read more

Citations
More filters
Journal ArticleDOI

Static synchronous compensators (STATCOM): a review

TL;DR: The Fast Acting Static Synchronous Compensator (STATCOM) as discussed by the authors is a representative of FACTS family and is extensively used as the state-of-theart dynamic shunt compensator for reactive power control in transmission and distribution system.
Journal ArticleDOI

Improving power system dynamics by series-connected FACTS devices

TL;DR: In this paper, a control strategy for the damping of electromechanical power oscillations using an energy function method is derived, which is shown to be effective both for damping large signal and small signal disturbances and are robust with respect to loading condition, fault location and network structure.
Journal ArticleDOI

Optimization and Coordination of Damping Controls for Improving System Dynamic Performance

TL;DR: In this paper, a global tuning procedure for FACTS device stabilizers and power system stabilizers in a multi-machine power system using a parameter-constrained nonlinear optimization algorithm implemented in a simulation program is presented.
Journal ArticleDOI

A Robust Control Strategy for Shunt and Series Reactive Compensators to Dame Electromechanical Oscillations

TL;DR: In this article, a control strategy for damping of electromechanical power oscillations using an energy function method is derived, and the effect of the damping effect is robust with respect to loading condition, fault location and network structure.
Proceedings ArticleDOI

Benefits of SVC and STATCOM for electric utility application

TL;DR: In this paper, the behavior of SVCs and STATCOMs in electric power systems is examined based on analytical and simulation analysis, and conclusions can be used as power industry guidelines.
References
More filters
Journal ArticleDOI

A mathematical model for lead-acid batteries

TL;DR: In this article, a mathematical model of a lead-acid battery is presented, which takes into account self-discharge, battery storage capacity, internal resistance, overvoltage, and environmental temperature.
Journal ArticleDOI

Reactive Power Generation and Control by Thyristor Circuits

TL;DR: In this paper, static var generators function as variable reactances (capacitive or inductive impedances) or controllable ac current and voltage sources, and new approaches are described in which power frequency changers (cycloconverters) are employed.
Journal ArticleDOI

Benefits of GTO-based compensation systems for electric utility applications

TL;DR: In this paper, the performance of reactive compensation systems based on gate-turnoff thyristors offers potential benefits compared to conventional compensators, such as increased steady-state loadability of heavily stressed systems, improving the security of systems with heavy motor loads, and improving the transient stability of systems experiencing large power swings.
Journal ArticleDOI

New Static VAR Control Using Forced-Commutated Inverters

TL;DR: In this article, the authors describe the system outline and the operating results of a new type of 20MVA Static VAR Generator (SVG), which is already in operation in electric power field since January of 1980.
Journal ArticleDOI

10 MW GTO converter for battery peaking service

TL;DR: In this article, a bidirectional 18-pulse voltage-source converter utilizing gate-turnoff thyristors (GTOs) was described, which was placed in service in early 1988 to connect an energy storage battery to a utility grid.
Related Papers (5)