Metal artifacts in patients with large dental implants and bridges: combination of metal artifact reduction algorithms and virtual monoenergetic images provides an approach to handle even strongest artifacts.

Reads0
Chats0
TLDR
In the presence of strong artifacts due to large oral implants, MAR is a powerful mean for artifact reduction and improves the diagnostic image assessment in imaging of the head and neck.
Abstract
This study compares reduction of strong metal artifacts from large dental implants/bridges using spectral detector CT-derived virtual monoenergetic images (VMI), metal artifact reduction algorithms/reconstructions (MAR), and a combination of both methods (VMIMAR) to conventional CT images (CI). Forty-one spectral detector CT (SDCT) datasets of patients that obtained additional MAR reconstructions due to strongest artifacts from large oral implants were included. CI, VMI, MAR, and VMIMAR ranging from 70 to 200 keV (10 keV increment) were reconstructed. Objective image analyses were performed ROI-based by measurement of attenuation (HU) and standard deviation in most pronounced hypo-/hyperdense artifacts as well as artifact impaired soft tissue (mouth floor/soft palate). Extent of artifact reduction, diagnostic assessment of soft tissue, and appearance of new artifacts were rated visually by two radiologists. The hypo-/hyperattenuating artifacts showed an increase and decrease of HU values in MAR and VMIMAR (CI/MAR/VMIMAR-200keV: − 369.8 ± 239.6/− 37.3 ± 109.6/− 46.2 ± 71.0 HU, p < 0.001 and 274.8 ± 170.2/51.3 ± 150.8/36.6 ± 56.0, p < 0.001, respectively). Higher keV values in hyperdense artifacts allowed for additional artifact reduction; however, this trend was not significant. Artifacts in soft tissue were reduced significantly by MAR and VMIMAR. Visually, high-keV VMI, MAR, and VMIMAR reduced artifacts and improved diagnostic assessment of soft tissue. Overcorrection/new artifacts were reported that mostly did not hamper diagnostic assessment. Overall interrater agreement was excellent (ICC = 0.85). In the presence of strong artifacts due to large oral implants, MAR is a powerful mean for artifact reduction. For hyperdense artifacts, MAR should be supplemented by VMI ranging from 140 to 200 keV. This combination yields optimal artifact reduction and improves the diagnostic image assessment in imaging of the head and neck. • Large oral implants can cause strong artifacts. • MAR is a powerful tool for artifact reduction considering such strong artifacts. • Hyperdense artifact reduction is supplemented by VMI of 140–200 keV from SDCT.

read more

Citations
More filters
Journal ArticleDOI

Deep learning-based metal artefact reduction in PET/CT imaging

TL;DR: In this paper, the authors investigated the potential of deep learning-based metal artefact reduction (MAR) in quantitative PET/CT imaging, and proposed a DLI-MAR approach to improve CT-based attenuation and scatter correction.
Journal ArticleDOI

A Review of the Applications of Dual-Energy CT in Acute Neuroimaging:

TL;DR: The basics of dual-energy CT are reviewed and many of its clinical applications in the evaluation of acute neurological presentations are highlighted, includingcium and bone subtraction can be used to distinguish hemorrhage from brain parenchymal mineralization.
Journal ArticleDOI

Biomechanical comparison of titanium miniplates versus a variety of CAD/CAM plates in mandibular reconstruction

TL;DR: A comparison of titanium plate fixation of free flaps in mandibular reconstruction involves complications such as osseous non-union or imaging artefacts and mechanical integrity of all titanium plates complies with established standards.
Journal ArticleDOI

Biomechanical comparison of polylactide-based versus titanium miniplates in mandible reconstruction in vitro

TL;DR: It is suggested that polylactide-based miniplates provide reduced mechanical integrity and higher interosteotomy movements in comparison to titanium miniplates in vitro.
References
More filters
Journal ArticleDOI

A Coefficient of agreement for nominal Scales

TL;DR: In this article, the authors present a procedure for having two or more judges independently categorize a sample of units and determine the degree, significance, and significance of the units. But they do not discuss the extent to which these judgments are reproducible, i.e., reliable.
Journal ArticleDOI

The equivalence of weighted kappa and the intraclass correlation coefficient as measures of reliability.

TL;DR: The use of kappa implicitly assumes that all disagreements are equally serious as discussed by the authors, which is not the case, and hence the use of the kappa scale implicitly implies that not all disagreements will be equally serious.
Journal ArticleDOI

Energy-selective reconstructions in X-ray computerized tomography.

TL;DR: It is shown that for any material, complete energy spectral information may be summarized by a few constants which are independent of energy, and a technique is presented which uses simple, low-resolution, energy spectrum measurements and conventional computerized tomography techniques to calculate these constants.
Journal ArticleDOI

First performance evaluation of a dual-source CT (DSCT) system.

TL;DR: First clinical experience shows a considerably increased robustness for the imaging of patients with high heart rates, and the automatic separation of bones and iodine-filled vessels is demonstrated as a potential application of the dual-energy acquisition mode.
Journal ArticleDOI

Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications

TL;DR: The underlying motivation and physical principles of dual- or multi-energy CT are reviewed, the current and evolving clinical applications are introduced and each of the current technical approaches is described.
Related Papers (5)