scispace - formally typeset
Journal ArticleDOI

Performance study of air-heated packed-bed solar-energy collectors

C.B. Mishra, +1 more
- 01 Feb 1981 - 
- Vol. 6, Iss: 2, pp 153-157
Reads0
Chats0
TLDR
A performance study of three packed-bed solar collectors for air-heating is presented in this paper, where the performance of plane collectors improves appreciably by packing with blackened metallic materials.
About
This article is published in Energy.The article was published on 1981-02-01. It has received 33 citations till now. The article focuses on the topics: Nanofluids in solar collectors & Thermal energy storage.

read more

Citations
More filters
Journal ArticleDOI

Novel approaches and recent developments on potential applications of phase change materials in solar energy

TL;DR: In this paper, phase change materials (PCMs) can be applied to several different solar energy systems for the extended heat energy storage which is quite useful as the solar energy is intermittent in nature and is unavailable during the night period.
Journal ArticleDOI

Experimental performance of single and double pass solar air heater with fins and steel wire mesh as absorber

TL;DR: In this paper, a single and double pass solar air heater with fins attached and using a steel wire mesh as absorber plate was investigated experimentally, and the effects of air mass flow rate range between 0.012 and 0.038 kg/s on the outlet temperature and thermal efficiency was studied.
Journal ArticleDOI

A thermodynamic review of solar air heaters

TL;DR: In this paper, the authors focus on the developments that have followed round the globe in various aspects of solar air heating systems since 1877 up to now, with a glimpse of some novel patents of SAHs.
Journal ArticleDOI

Performance of a double pass solar air collector

TL;DR: In this paper, a mathematical model has been developed based on volumetric heat transfer coefficient for double pass solar air collector with and without porous material, and the effects of various parameters on the thermal performance and pressure drop characteristics have been discussed.
Journal ArticleDOI

Year round performance of double pass solar air heater with packed bed

TL;DR: In this paper, the thermal performance of a double glass, double pass solar air heater with a packed bed (DGDPSAHPB) was investigated experimentally and theoretically.
References
More filters

Natural convection in enclosed spaces - A review of application to solar energy collection

TL;DR: In this article, the spacing between the hot solar absorber and successive glass covers should be in the range 4 to 8 cm to assure minimum gap conductance, based on the theory and some experimental measurements.
Journal ArticleDOI

Natural Convection in Enclosed Spaces—A Review of Application to Solar Energy Collection

TL;DR: In this article, the spacing between the hot solar absorber and successive glass covers should be in the range 4 to 8 cm to assure minimum gap conductance, based on the theory and some experimental measurements.
Book ChapterDOI

Cheap packed bed absorbers for solar air heaters

TL;DR: In this paper, the feasibility of using two cheap packed bed absorbers for solar air heaters has been investigated, which consist of iron shavings and iron wires, and their performance was studied experimentally, with single glass cover, two glass covers, single pass flow, two pass flow.
Book ChapterDOI

Thermal performance of solar collectors used in the national solar heating and cooling demonstration program

Pandit G. Patil, +1 more
TL;DR: In this paper, a report on the analyses and evaluation of collectors used in the national demonstration program for solar heating and cooling of non-residential buildings is presented, comparing collectors in cost, design, and thermal performance.
Related Papers (5)