Showing papers in "Ultraschall in Der Medizin in 2016"


Journal ArticleDOI

259 citations


Journal ArticleDOI
TL;DR: This position statement of the European Federation of Societies in Ultrasound and Medicine (EFSUMB) assesses the current status of CEUS applications in children and makes suggestions for further development of this technique.
Abstract: The use of contrast-enhanced ultrasound (CEUS) in adults is well established in many different areas, with a number of current applications deemed “off-label”, but the use supported by clinical experience and evidence. Paediatric CEUS is also an “off-label” application until recently with approval specifically for assessment of focal liver lesions. Nevertheless there is mounting evidence of the usefulness of CEUS in children in many areas, primarily as an imaging technique that reduces exposure to radiation, iodinated contrast medium and the “patient-friendly” circumstances of ultrasonography. This position statement of the European Federation of Societies in Ultrasound and Medicine (EFSUMB) assesses the current status of CEUS applications in children and makes suggestions for further development of this technique.

153 citations


Journal ArticleDOI
TL;DR: In the last 12 - 18 months nearly all ultrasound manufacturers have arrived to implement ultrasound shear wave elastography modality in their equipment for the assessment of chronic liver disease; the few remaining players are expected to follow in 2016, and pSWE appears to provide greater applicability than transientElastography, although the calculated thresholds for the different fibrosis stages and the stiffness ranges between the two techniques are not superimposable.
Abstract: In the last 12 – 18 months nearly all ultrasound manufacturers have arrived to implement ultrasound shear wave elastography modality in their equipment for the assessment of chronic liver disease; the few remaining players are expected to follow in 2016. When all manufacturers rush to a new technology at the same time, it is evident that the clinical demand for this information is of utmost value. Around 1990, there was similar demand for color Doppler ultrasound; high demand for contrast-enhanced ultrasonography was evident at the beginning of this century, and around 2010 demand increased for strain elastography. However, some issues regarding the new shear wave ultrasound technologies must be noted to avoid misuse of the resulting information for clinical decisions. As new articles are expected to appear in 2016 reporting the findings of the new technologies from various companies, we felt that the beginning of this year was the right time to present an appraisal of these issues. We likewise expect that in the meantime EFSUMB will release a new update of the existing guidelines 1 2 . The first ultrasound elastography method became available 13 years ago in the form of transient elastography with Fibroscan ® 3 . It was the first technique providing non-invasive quantitive information about the stiffness of the liver and hence regarding the amount of fibrosis in chronic liver disease 3 . The innovation was enormous, since a non-invasive modality was finally available to provide findings otherwise achievable only by liver biopsy. In fact, prior to ultrasound elastography, a combination of conventional and Doppler ultrasound parameters were utilized to inform the physician about the presence of cirrhosis and portal hypertension 4 . However, skilled operators were required, reproducibility and diagnostic accuracy were suboptimal, and it was not possible to differentiate the pre-cirrhotic stages of fibrosis. All these limitations were substantially improved by transient elastography, performed with Fibroscan ® , a technology dedicated exclusively to liver elastography. Since then, more than 1300 articles dealing with transient elastography have been listed in PubMed, some describing results with more than 10,000 patients 5 . The technique has been tested in nearly all liver disease etiologies, with histology as the reference standard. Meta-analysis of data, available in many etiologies 6 , showed good performance and reproducibility as well as some situations limiting reliability 5 . Thresholds for the different fibrosis stages (F0 to F4) have been provided by many large-scale studies utilizing histology as the reference standard 7 . Transient elastography tracks the velocity of shear waves generated by the gentle hit of a piston on the skin, with the resulting compression wave traveling in the liver along its longitudinal axis. The measurement is made in a 4 cm long section of the liver, thus able to average slightly inhomogeneous fibrotic deposition. In 2008 a new modality became available, Acoustic Radiation Force Impulse (ARFI) quantification, and classified by EFSUMB 1 as point shear wave elastography (pSWE), since the speed of the shear wave (perpendicular to the longitudinal axis) is measured in a small region (a “point”, few millimeters) at a freely-choosen depth within 8 cm from the skin. This technology was the first to be implemented in a conventional ultrasound scanner by Siemens ® 8 . Several articles have been published regarding this technology, most with the best reference standards 9 , some including findings on more than 1000 hepatitis C patients 10 or reporting meta-analysis of data 11 . Although the correlation between Siemens pSWE and transient elastography appeared high 12 13 , the calculated thresholds for the different fibrosis stages and the stiffness ranges between the two techniques are not superimposable. Interestingly, pSWE appears to provide greater applicability than transient elastography for measuring both liver 13 and spleen stiffness, which is a new application of elastography 14 , of interest for the prediction of the degree of portal hypertension 15 16 . Nowadays other companies have started producing equipment with pSWE technology, but only very few articles have been published so far, for instance describing the use of Philips ® equipment, which was the second to provide pSWE. These articles show preliminary good results also in comparison with TE 17 18 . Not enough evidence is currently available in the literature about the elastographic performance of the products most recently introduced to the market. Furthermore, with some products the shear wave velocities generated by a single ultrasound acoustic push pulse can be measured in a bidimensional area (a box in the range of 2 – 3 cm per side) rather than in a single small point, producing a so-called bidimensional 2D-SWE 1 . The stiffness is depicted in color within the area and refreshing of the measurement occurs every 1 – 2 seconds. Once the best image is acquired, the operator chooses a Region Of Interest (ROI) within the color box, where the mean stiffness is then calculated. 2D-SWE can be performed as a “one shot” technique or as a semi-“real-time” technique for a few seconds (at about 1 frame per second) in order to obtain a stable elastogram. With either technique, there should be no motion/breathing during image acquisition. A bidimensional averaged area should overcome the limitation of pSWE to inadvertently investigate small regions of greater or lesser stiffness than average. A shear wave quality indicator could be useful to provide real-time feedback and optimize placement of the sampling ROIs, a technology recently presented by Toshiba ® , but which is still awaiting validation in the literature. Supersonic Imagine by Aixplorer ® which works with a different modality of insonation and video analysis compared to the the previously-mentioned three techniques (i. e., transient elastography, pSWE and 2D-SWE), leading to a bidimensional assessment of liver stiffness in real time up to 5 Hz and in larger regions; thus this technique is also termed real-time 2 D SWE. It has been available on the market for a few years 19 20 , and many articles have been published showing stiffness values quite similar to those of Fibroscan ® 21 ; likewise, defined thresholds based on histological findings have appeared in several articles 19 20 21 . After this brief summary of the technological state of the art we would like to mention the following critical issues that we believe every user should note prior to providing liver stiffness reports. In conclusion, the technological progression of ultrasound methods in hepatology has been rapid and exciting. However, caution should be applied when describing the findings of the most recent shear wave ultrasound technologies and, even more importantly, more scientific evidence must be produced before their results are adopted to modify clinical choices, such as initiating ultrasound surveillance in chronic liver disease or screening for varices by endoscopy. This likewise applies to starting expensive antiviral treatments or predicting prognosis. Different technologies might not necessarily be mutually exclusive and whether the combination of multiple elastographic methods with the same patient might produce a more accurate assessment than a single optimal method appears worth to be investigated. Answering all the above mentioned critical issues will require solid single-center research, multicenter evaluations, new expert consensus and updated guidelines.

112 citations


Journal ArticleDOI
TL;DR: The fifth section of the Guidelines on Interventional Ultrasound (INVUS) assesses the evidence for all the categories of endoscopic ultrasound-guided treatment reported to date and summarizes into major recommendations for reader consultation.
Abstract: The fifth section of the Guidelines on Interventional Ultrasound (INVUS) of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) assesses the evidence for all the categories of endoscopic ultrasound-guided treatment reported to date. Celiac plexus neurolysis and block, vascular intervention, drainage of fluid collections, drainage of biliary and pancreatic ducts, and experimental tumor ablation techniques are discussed. For each topic, all current evidence has been extensively analyzed and summarized into major recommendations for reader consultation (short version; the long version is published online).

63 citations


Journal ArticleDOI
TL;DR: The approval of microbubbles with the inert gas sulfur hexafluoride (SF6) and a palmitic acid shell (SonoVue(®), Bracco Geneva, CH) for the diagnostic imaging of liver tumors in adults and children by the FDA in the United States represents a milestone for contrast-enhanced ultrasound (CEUS).
Abstract: The approval of microbubbles with the inert gas sulfur hexafluoride (SF6) and a palmitic acid shell (SonoVue(®), Bracco Geneva, CH) for the diagnostic imaging of liver tumors in adults and children by the FDA in the United States represents a milestone for contrast-enhanced ultrasound (CEUS).This warrants a look back at the history of the development of CEUS. The first publications based on echocardiographic observations of right ventricular contrast phenomena caused by tiny air bubbles following i. v. injection of indocyanine green appeared around 1970 1 2 3. A longer period of sporadic publications but no real progress then followed since, in contrast to X-ray methods, ultrasound works quite well without a contrast agent.It is noteworthy that the foundations for further development were primarily laid in Europe. The development and approval (1991) of the contrast agent Echovist(®) by a German contrast manufacturer for echocardiography unsuitable for passing through lungcapillaries 4 5 resulted in the first extracardiac indications, e. g. for detecting retrovesical reflux and tubal patency, in the mid-1980 s 6 7 8. The sensitivity of color Doppler was not able to compensate for the lack of an ultrasound contrast agent compared to CT with its obligatory contrast administration.Studies of SHU 508 - microbubbles of air moderately stabilized with galactose and palmitic acid - began in 1990 9 10 11 12 13 14 15 and the contrast agent was then introduced in 1995 in Germany as Levovist(®). The most important publications by Blomley, Cosgrove, Leen, and Albrecht are named here on a representative basis 16 17 18 19 20.SHU 508 along with other US contrast agents provided impressive proof of the superiority of CEUS for the diagnosis of liver metastases. However, practical application remained complicated and required skill and technical know-how because of a lack of suitable software on US units 21 22 23 24 25. The monograph regarding the use of contrast agent in the liver by Wermke and Gaßmann is impressive but unfortunately only available in German 26. In addition to being applied in the heart and the liver, CEUS was first used in transcranial applications 27 and in vessels 28, the kidneys 29, and the breast 30. Measurements at transit times were also of particular interest 31. It was difficult to convince ultrasound device manufacturers of the need to adapt US units to US contrast agents and not vice versa.The breakthrough came with low MI phase contrast inversion and the introduction of SonoVue(®) in many European countries in 2001. This more stable US contrast agent is easy to use and is becoming indispensable in diagnostic imaging of the liver 32 33 34 35 36 37 38 39 40. Studies have shown its excellent tolerability 41 and diagnostic reliability comparable to that of MDCT and MRI in the liver 42 43. Today it would be unimaginable to diagnose liver tumors without CEUS 44. This also applies to very small lesions 45 46.EFSUMB published the first CEUS guidelines in 2004 47 which have since been reissued and divided into hepatic 48 and extrahepatic applications 49. The first recommendations regarding quantitative assessment have also been published 50.The increasing scientific interest in CEUS is evident based on the greater number of PubMed hits for Echovist(®) (ca. 130), Levovist(®) (ca. 500) and SonoVue(®) (ca. 1500) as well as on the fact that publications regarding CEUS comprise almost 20 % of UiM/EJU articles in the last 10 years. The number of CEUS articles in UiM/EJU continues to be high 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75.In the clinical reality, CEUS has been able to become established alongside CT and MRI according to the saying \"better is the enemy of good\" 76 as the method of choice after B-mode ultrasound in the evaluation of liver tumor malignancy in Germany, where the technically challenging method is promoted. In the case of unclear CT and MRI findings, CEUS performed by an experienced examiner/clinician often provides the solution, particularly in the case of small lesions, and is the last resort before US-guided biopsy 45 46. However, there is a lack of competent CEUS examiners and Germany continues to be the world champion of X-ray examinations with no noticeable reverse trend. In almost every doctor's office and hospital, ultrasound costs are by far not fully covered, resulting in an extremely high frequency of CT use with CT being available to everyone regardless of insurance status.The USA is now in the starting position for CEUS. It will be exciting to see how the method will develop there. The FDA's decision to approve sulfur hexafluoride (Lumason(®) = SonoVue(®)) should be considered against the background of the radiation exposure caused by CT examinations and the fact that MRI using gadolinium-containing contrast agents is no longer considered noninvasive because of nephrogenic systemic fibrosis (NSF) and the accumulation of the agent in the cerebrum. An essential point of the campaign regarding the avoidance of diagnostic radiation exposure triggered in the USA by the publications of Brenner et al. 77 78 was that the agent was approved for use in the liver even for children 79 80 - still off label in Europe - without additional comprehensive studies due to the available scientific results and the very low side effects profile of Lumason(®) (= SonoVue(®)). It is admittedly unclear why other indications (except the heart which has been approved since 2014) are excluded even though the microbubbles as a pure blood pool contrast agent can be diagnostically used in the entire vascular system and bed of all organs. To our knowledge, there is no such restriction on the approval of X-ray contrast agents.Like echocardiography and emergency ultrasound, CEUS began in Europe but will probably only establish its final diagnostic value as a \"reimport\".This is a major opportunity to permanently define the role of Ultrasound as a highly valuable, patient-centered imaging method in the German health care system.This may prompt some of our international readers to reflect upon the role of CEUS in their own countries.

63 citations


Journal ArticleDOI
TL;DR: A high quality 2D-SWE elastogram ensures low variability and high reliability, regardless of indication, and is recommended for a combination of low standard deviation and large ROI.
Abstract: Purpose Liver stiffness measurement by real-time 2-dimensional shear wave elastography (2D-SWE) lacks universal reliability criteria. We sought to assess whether previously published 2D-SWE reliability criteria for portal hypertension were applicable for the evaluation of liver fibrosis and cirrhosis, and to look for criteria that minimize the risk of misclassification in this setting. Materials and Methods In a biopsy-controlled diagnostic study, we obtained five 2D-SWE measurements of optimal image quality. Correctly classified cases of fibrosis and cirrhosis were compared to misclassified cases. We compared reliability predictors (standard deviation (SD), SD/mean, size of region of interest (ROI) and difference between a single measurement and the patient’s median) with those obtained in a prior study on clinically significant portal hypertension. Results We obtained 678 2D-SWE measurements from 142 patients. Overall, the variability in liver stiffness within single 2D-SWE measurements was low (SD = 1.1 ± 1.5kPa; SD/mean = 12 ± 9 %). Intra-observer analysis showed almost perfect concordance (intraclass correlation coefficient = 0.95; 95 % CI 0.94 – 0.96; average difference from median = 0.4 ± 0.9kPa). For the diagnosis of cirrhosis, a smaller SD (optimally ≤ 1.75 kPa) and larger ROI size (optimally ≥ 18 mm) were associated with higher accuracy. Similarly, within the published cohort of patients assessed for portal hypertension, a low variability of measurements was associated with high reliability. Conclusion A high quality 2D-SWE elastogram ensures low variability and high reliability, regardless of indication. We recommend aiming for a combination of low standard deviation and large ROI.

46 citations


Journal ArticleDOI
TL;DR: The most important pathologies of cystic lesions of the kidney are explained and the different imaging methods of native B-mode sonography and the new techniques of contrast enhanced ultrasound are stressed.
Abstract: Ultrasound is the most used interdisciplinary non-ionizing imaging technique in clinical routine. Therefore, ultrasound has a special value in the diagnosis and monitoring of cystic renal lesions, which can be classified as non-complicated or complicated and by means of occurrence as solitary or multifocal lesions. The Bosniak classification (I-IV) classifies renal cysts in 5 different categories with the help of ultrasound and computed tomography image criteria and is used for decisions of further clinical treatment. Additionally to normal native B-mode sonography, several new methods are in clinical use to improve diagnostic accuracy of unclear cases. Contrast enhanced ultrasound and MRI/CT are able to find and characterize difficult pathologies. This review explains the most important pathologies of cystic lesions of the kidney and stresses the different imaging methods of native B-mode sonography and the new techniques of contrast enhanced ultrasound.

43 citations


Journal ArticleDOI
TL;DR: LI-RADS-CEUS offers a CEUS algorithm for standardized assessment and reporting of focal liver lesions in patients at risk for HCC, whereas washout is not a necessary prerequisite.
Abstract: Purpose: To develop a contrast-enhanced ultrasound algorithm (LI-RADS-CEUS = liver imaging reporting and data system with contrast-enhanced ultrasound) for the diagnosis of hepatocellular carcinoma (HCC) in patients at risk. Materials and Methods: A CEUS algorithm (LI-RADS-CEUS) was designed analogously to CT- and MRI-based LI-RADS. LI-RADS-CEUS was evaluated retrospectively in 50 patients at risk with confirmed HCC or non-HCC lesions (test group) with subsequent validation in a prospective cohort of 50 patients (validation group). Results were compared to histology, CE-CT and CE-MRI as reference standards. Results: Tumor diagnosis in the test group/validation group (n = 50/50) were 46/41 HCCs, 3/3 intrahepatic cholangiocellular carcinomas (ICCs) and 1/6 benign lesions. The diagnostic accuracy of LI-RADS-CEUS for HCC, ICC and non-HCC-non-ICC-lesions was 89 %. For the diagnosis of HCC, the diagnostic accuracy was 93.5 % (43/46 cases) in the test group and 95.1 % (39/41 cases) in the validation group. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 94.3 %, 66.6 %, 94.3 % and 66.6 %, respectively (mean values from both cohorts). Histological findings of HCC were available in 40 versus 23 cases (in total: G1 / G2/G3: 15/35/13). Arterial hyperenhancement was seen in 68/87 (78.2 %) of HCCs. Arterial hyperenhancement with subsequent portal venous or late phase hypoenhancement was seen in 66 % of HCCs. Conclusion: LI-RADS-CEUS offers a CEUS algorithm for standardized assessment and reporting of focal liver lesions in patients at risk for HCC. Arterial hyperenhancement in CEUS is the key feature for the diagnosis of HCC in patients at risk, whereas washout is not a necessary prerequisite.

42 citations


Journal ArticleDOI
TL;DR: In this paper, the authors evaluated the value of SE for the differentiation of thyroid nodules in a prospective multicenter study and concluded that SE as an additional ultrasound tool improves the value for the work-up of thyroid nodes.
Abstract: Purpose: Many patients with thyroid nodules are presently referred to surgery for not only therapeutic but also diagnostic purposes. The aim of noninvasive diagnostic methods is to optimize the selection of patients for surgery. Strain elastography (SE) enables the ultrasound-based determination of tissue elasticity. The aim of the present study was to evaluate the value of SE for the differentiation of thyroid nodules in a prospective multicenter study. Materials and Methods: The study was registered at clinicaltrials.gov and was approved by the local ethics committees of all participating centers. All patients received an ultrasound (US) of the thyroid gland including color Doppler US. In addition, all nodules were evaluated by SE (Hitachi Medical Systems) using qualitative image interpretation of color distribution (SE-ES), strain value and strain ratio. Results: Overall, 602 patients with 657 thyroid nodules (567 benign, 90 malignant) from 7 centers were included in the final analysis. The sensitivity, specificity, NPV, PPV, +LR were 21 %, 73 %, 86 %, 11 %, 0.8, respectively, for color Doppler US; 69 %, 75 %, 94 %, 30 %, 2.9, respectively, for SE-ES; 56 %, 81 %, 92 %, 32 %, 2.9, respectively, for SE-strain value; and 58 %, 78 %, 92 %, 30 %, 2.6, respectively, for SE-strain ratio. The diagnostic accuracy was 71 % for both strain value and strain ratio of nodules. Conclusion: SE as an additional ultrasound tool improves the value of ultrasound for the work-up of thyroid nodules. It might reduce diagnostic surgery of thyroid nodules in the future.

41 citations


Journal ArticleDOI
TL;DR: The measurement of nuchal translucency (NT) allows the risk calculation for the fetal trisomies 21, 18 and 13 but also gives information on those fetal chromosomal defects which are at present unable to be detected using cffDNA.
Abstract: The early fetal ultrasound assessment at 11 – 13+6 weeks of gestation remains the cornerstone of care despite the progress in diagnosing fetal chromosomal defects using cell-free fetal DNA (cffDNA) from the maternal circulation. The measurement of nuchal translucency (NT) allows the risk calculation for the fetal trisomies 21, 18 and 13 but also gives information on those fetal chromosomal defects which are at present unable to be detected using cffDNA. Nuchal translucency is the only auditable parameter at 11 – 13+6 weeks and gives thus information on the quality of the first trimester anomaly scan. In addition it gives indirect information on the risks for fetal defects and for cardiac anomalies. Also the chances for a healthy live baby can be estimated. As experience with first trimester anomaly scanning increases, and the resolution of the ultrasound equipment has increased substantially, more and more details of the fetal anatomy become accessible at the first trimester scan. Therefore fetal anatomical defects and complex anomalies have become amenable to examination in the first trimester. This guideline describes compulsory and optional parameters for investigation at the first trimester scan and outlines a structured method of examining a first trimester fetus at 11 – 13+6 weeks of gestation.

35 citations


Journal ArticleDOI
TL;DR: Policy statements on medical student education in ultrasound recommend that medical students should acquire theoretical knowledge of the modality and hands-on training should be implemented and adhere to evidence-based principles.
Abstract: The European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) recommends that ultrasound should be used systematically as an easy accessible and instructive educational tool in the curriculum of modern medical schools. Medical students should acquire theoretical knowledge of the modality and hands-on training should be implemented and adhere to evidence-based principles. In this paper we summarise EFSUMB policy statements on medical student education in ultrasound.

Journal ArticleDOI
TL;DR: Investigating the sensitivity of high resolution ultrasound, standard contrast-enhanced ultrasound and CEUS using a novel vascular endothelial growth factor receptor 2 (VEGFR2)-targeted contrast agent for the detection of hepatic metastases in a mouse model of colorectal cancer found it was earlier and more accurate than monitoring via bioluminescence.
Abstract: Purpose: Aim of the present study was to investigate the sensitivity of high resolution ultrasound (HRU), standard contrast-enhanced ultrasound (CEUS) and CEUS using a novel vascular endothelial growth factor receptor 2 (VEGFR2)-targeted contrast agent for the detection of hepatic metastases in a mouse model of colorectal cancer using clinical standard technology. Materials and Methods: The human colon cancer cell line HT29, transfected with luciferase cDNA for in vivo bioluminescence monitoring, was injected intrasplenically into CB17.SCID mice. Mice were monitored weekly by bioluminescence and after 2 and 4.5 weeks by HRU and CEUS. Contrast media (untargeted BR1, targeted BR55) was applied and digital cine loops from the arterial phase (15 – 45 sec), portal venous phase (50 – 120 s) and late phases (3 – 5 min, 1hour) of the whole liver were analyzed. Data were correlated with postmortem histopathology. Results: Without contrast enhancement, lesions > 4 mm were reliably detected. After use of untargeted CEUS, lesions > 2 mm were reliably detected and enhanced rim vascularization and late-phase wash-out was shown. With BR55, lesions > 0.8 mm were reliably detected with excellent documentation of vascularization. A persistent contrast enhancement was seen > 30 min after injection. Contrast-enhancement patterns with BR55 significantly correlated with CD31 (R2 = 0.74) and VEGFR2-immunohistochemistry (R2 = 0.66). Conclusion: Detection of metastases by HRU and CEUS was earlier and more accurate than monitoring via bioluminescence. In vivo monitoring of hepatic micrometastases can thus be performed without prior modification of cancer cells using standard technology.

Journal ArticleDOI
TL;DR: CEUS is a well-tolerated and diagnostically equivalent modality in pediatric care, providing fundamental advantages compared to currently approved imaging modalities for these age groups.
Abstract: Purpose: To investigate the spectrum, applicability and diagnostic capacity of intravenous contrast-enhanced ultrasound imaging (CEUS) in a pediatric population. Materials and Methods: From 08/2005 to 11/2015, n = 40 pediatric patients and young adults from 0 - 26 years (O 11.4 ± 7.5) and 3.0 - 85.3 kg (O 40.8 ± 25.6) with n = 55 investigations received n = 79 IV applications of ultrasound contrast agent (UCA). UCA dose and side effects were documented. Scanned organs were the liver (n = 42), spleen (n = 9), kidney (n = 3), and testis (n = 1). Histology, surgery or reference imaging was compared to CEUS and clinical follow-up. Results: The UCA dose 20 kg was 1.0 ± 0.4 ml (p< 0.0001) (0.02 ± 0.01 ml/kg, p< 0.0001). Adverse effects occurred in 2/79 applications (2.5 %). Agreement CEUS/gold standard resulted in 32/34 investigations. For liver diagnostics (gold standard: MRI, CT, histology, serology), n = 11 malignant and n = 15 benign focal liver lesions were included. The specificity was 100 % (95 % CI: 0.77 - 1.00), the sensitivity was 82 % (95 % CI: 0.48 - 0.98), the positive predictive value was 100 % (95 % CI: 0.69 - 1.00) and the negative predictive value was 88 % (95 % CI: 0.62 - 0.98, p< 0.0001). In n = 2 reference imaging misdiagnosed and CEUS was in accordance with clinical follow-up. All splenic/renal lesions were diagnosed correctly. In n = 1 an insufficient testicular perfusion was ruled out. The observation time was 30.4 ± 30.5 months. Conclusion: CEUS is a well-tolerated and diagnostically equivalent modality in pediatric care, providing fundamental advantages compared to currently approved imaging modalities for these age groups.

Journal ArticleDOI
TL;DR: It is found that validity evidence for the assessment of mastery learning in simulation-based ultrasound training can be demonstrated and that ultrasound novices can attain mastery learning levels with less than 5 hours of training.
Abstract: Purpose: To collect validity evidence for the assessment of mastery learning on a virtual reality transabdominal ultrasound simulator. Materials and Methods: We assessed the validity evidence using Messick’s framework for validity. The study included 20 novices and 9 ultrasound experts who all completed 10 obstetric training modules on a transabdominal ultrasound simulator that provided automated measures of performance for each completed module (i. e., simulator metrics). Differences in the performance of the two groups were used to identify simulator metrics with validity evidence for the assessment of mastery learning. The novices continued to practice until they had attained mastery learning level. Results: One-third of the simulator metrics discriminated between the two groups. The median simulator scores from a maximum of 40 metrics were 17.5 percent (range 0 – 45.0 percent) for novices and 90.0 percent (range 85.0 – 97.5) for experts, p Conclusion: This study found that validity evidence for the assessment of mastery learning in simulation-based ultrasound training can be demonstrated and that ultrasound novices can attain mastery learning levels with less than 5 hours of training. Only one-third of the standard simulator metrics discriminated between different levels of competence.

Journal ArticleDOI
TL;DR: A current review of benign and malignant parotid gland tumors with emphasis on the role of multiparametric US and MR imaging is presented.
Abstract: High-resolution ultrasound (US), as a readily available, cost-effective and harmless imaging technique, is appropriately the initial imaging modality for salivary gland lesions. Benign tumors are reported to present with regular and well-defined margins, a homogeneous hypoechoic structure and demarcated vessel distribution, whereas malignant lesions are irregular, heterogeneous and diffusely perfused. Ultrasound and color Doppler features of benign and malignant salivary gland lesions overlap, and many benign tumors, particularly pleomorphic adenomas, may appear irregularly shaped, with a heterogeneous echo-structure indistinguishable from a malignant lesion. Often skilled US operators are not always able to differentiate benign from malignant lesions. The introduction of US contrast agents has allowed further perspectives in the possible improvement of lesion characterization, and the emergence of US elastography, an innovative tool for assessing lesion stiffness/elasticity characteristics, has been advocated for differentiating salivary gland lesions. When lesions are atypical on US, contrast-enhanced magnetic resonance (MR) imaging is usually the definitive imaging modality. We present a current review of benign and malignant parotid gland tumors with emphasis on the role of multiparametric US and MR imaging.

Journal ArticleDOI
TL;DR: There may be differences between journals for different medical specialties since the citations in some areas seem to "burn out" within a few years while some articles continue to be cited even after several years while a citation window that is longer than 2 years has been proposed.
Abstract: The impact factor (IF) for 2015 was recently released and this could be the time to once again reflect on its use as a metric of a journal. Problems and concerns regarding the IF have been addressed extensively elsewhere. The principle of the IF for a given year is that it represents the average number of citations of articles published in the journal in the two previous years.While authors frequently cite the IF as a determining factor for submission, the IF does not predict how many times individual articles will be cited. In a study from a peer-reviewed cardiovascular journal, nearly half of all published articles were poorly cited, i. e., less than five citations in five years. A similar percentage seems to apply to our journal. In nearly all journals we estimate that the majority of citations relate to a minority of the articles. Some articles are never cited. 13 % of the articles published in our journal from 2010 to 2013 have never been cited. Even authors of poorly cited articles benefit from the IF since many institutions use the combined impact factors of their published papers to measure research activity and this may be reflected in their research budgets. The competition for the printed pages in the six annual issues of Ultraschall in der Medizin/European Journal of Ultrasound (UiM/EJU) has resulted in high rejection rates (between 80 % and 90 %). One negative review with recommendation of major revision may therefore result in rejection. Peer-review fraud where the submitting author listed recommended reviewers with fake email addresses supplying fabricated peer reviews has recently been described in the New England Journal of Medicine. Some of the editors of our journal believe they have experienced this as well. Fabricating reviews in order to get a high IF for an article is to be considered fraud and is inexcusable. One aspect of using impact factors as a measure of the quality of a journal is that the IF only goes back two years. There may be differences between journals for different medical specialties since the citations in some areas seem to "burn out" within a few years while some articles continue to be cited even after several years. Therefore, a citation window that is longer than 2 years has been proposed. For this editorial we took a look at the 60 articles published in UiM/EJU in 2010. Half of them were no longer being cited in 2015. However, 10 articles were cited more than 5 times in 2015, and 5 of these were cited more than 10 times. It therefore seems that many of our articles have a long scientific life and generate more citations than indicated by the IF. Moreover, some articles have the highest number of citations after three years when they are no longer contributing to the impact factor. The most frequently cited articles from 2010 were multicenter studies, recommendations, and papers on hot topics like contrast-enhanced ultrasound (CEUS) and elastography, but it should be noted that there were also articles on the same topics that were poorly cited.The same trending topics continued into 2013 now topped by European guidelines and recommendations. 9 of the 10 most cited articles we published in 2014 were on CEUS or elastography, but the most cited article from that year so far has been on peripheral nerves. Surprisingly many good scientific papers on obstetrics/fetal US and musculoskeletal US have low citation rates. Our predictions for 2016 based on the topics of submitted articles in the last 12 months are that CEUS and elastography will continue to be popular topics.It is also worth mentioning that there can be a discrepancy between which titles are cited and which are accessed online. In addition to international guidelines, our CME articles are usually popular according to online access. CME articles are well established educational papers but they are rarely cited for the IF. Looking at the most read full-text recent articles on our journal's website shows that multicenter studies as well as recommendations backed by a national society or by the EFSUMB (European Federation of Societies for Ultrasound in Medicine and Biology) are still important. Upcoming important topics appear to be pediatric use of CEUS, simulation training and the introduction of ultrasound to medical students. Some of these are also backed by EFSUMB.A recent paper on the IF of radiology journals found that subspecialty radiology journals had a higher IF than general radiology journals. This could prove a challenge to interdisciplinary journals like ours but we take pride in continuing to cover all aspects of ultrasound in more than 15 fields. The distribution between reviews, original articles and case reports in a journal is worth addressing. An important aspect of a journal is the publication of original scientific research articles. CME articles, pictorials and letters are important for other reasons but are cited at a lower rate. The value of case reports with regard to the IF is low since they are rarely cited and we have observed that some journals have abandoned the publication of case reports, thus leaving them to spin-off journals. The rationale is that keeping case reports in a journal will only increase the denominator, thereby decreasing the IF. At our journal we have seen a decline in case report submissions but still want to publish them and even put one case on the front cover of every issue. Case reports still hold an educational value and are important to our readers. In conclusion, a healthy mix of original articles, CME articles, reviews and case reports combined with a few international guidelines and recommendations is important to UIM/EJU. Although we see popular topics like CEUS and elastography, it is not possible to predict which articles will be read or even cited based on the topic, with multicenter studies being the exception.© Georg Thieme Verlag KG Stuttgart · New York. Language: en

Journal ArticleDOI
TL;DR: The included studies were heterogeneous in the choice of simulator, study design, participants, and outcome measures, and the level of evidence for effect was inadequate; therefore, further research should be based on randomized controlled trials using tests with validity evidence and blinded assessors.
Abstract: Purpose: The aim is to provide a complete overview of the different simulation-based training options for abdominal ultrasound and to explore the evidence of their effect. Materials and Methods: This systematic review was performed according to the PRISMA guidelines and Medline, Embase, Web of Science, and the Cochrane Library was searched. Articles were divided into three categories based on study design (randomized controlled trials, before-and-after studies and descriptive studies) and assessed for level of evidence using the Oxford Centre for Evidence Based Medicine (OCEBM) system and for bias using the Cochrane Collaboration risk of bias assessment tool. Results: Seventeen studies were included in the analysis: four randomized controlled trials, eight before-and-after studies with pre- and post-test evaluations, and five descriptive studies. No studies scored the highest level of evidence, and 14 had the lowest level. Bias was high for 11 studies, low for four, and unclear for two. No studies used a test with established evidence of validity or examined the correlation between obtained skills on the simulators and real-life clinical skills. Only one study used blinded assessors. Conclusion: The included studies were heterogeneous in the choice of simulator, study design, participants, and outcome measures, and the level of evidence for effect was inadequate. In all studies simulation training was equally or more beneficial than other instructions or no instructions. Study designs had significant built-in bias and confounding issues; therefore, further research should be based on randomized controlled trials using tests with validity evidence and blinded assessors.

Journal ArticleDOI
TL;DR: The present article summarizes the guidelines and the recommendations regarding the application and documentation of ultrasound findings for the diagnosis of brain circulatory arrest in children and adults, as valid in Germany.
Abstract: Extra- and transcranial sonography of brain-supplying arteries is accepted worldwide in brain death protocols as a valid “ancillary” method of proving brain circulatory arrest. Color-coded duplex sonography and CT angiography have been newly incorporated in the fourth update of the German Medical Association’s guidelines for the determination of the irreversible cessation of brain function (“brain death”), effective July 2015. The updated guidelines address in more detail the diagnostic procedures and the required qualifications of the examiners. The present article summarizes the guidelines and the recommendations regarding the application and documentation of ultrasound findings for the diagnosis of brain circulatory arrest in children and adults, as valid in Germany. The method, limitations, and procedure in the case of inconclusive findings are described. Age-related minimum values of mean arterial pressure for the diagnosis of cerebral circulatory arrest in children are presented. A concise overview of the respective regulations for the use of sonography for diagnosing brain death in other countries, especially in the countries neighboring Germany, is given.

Journal ArticleDOI
TL;DR: A double layer closure of the hysterotomy is associated with a thicker myometrium scar only in primary or elective Cesarean delivery patients.
Abstract: Purpose We undertook a randomized clinical trial to examine the outcome of a single vs. a double layer uterine closure using ultrasound to assess uterine scar thickness. Materials and Methods Participating women were allocated to one of three uterotomy suture techniques: continuous single layer unlocked suturing, continuous locked single layer suturing, or double layer suturing. Transvaginal ultrasound of uterine scar thickness was performed 6 weeks and 6 – 24 months after Cesarean delivery. Sonographers were blinded to the closure technique. Results An “intent-to-treat” and “as treated” ANOVA analysis included 435 patients (n = 149 single layer unlocked suturing, n = 157 single layer locked suturing, and n = 129 double layer suturing). 6 weeks postpartum, the median scar thickness did not differ among the three groups: 10.0 (8.5 – 12.3 mm) single layer unlocked vs. 10.1 (8.2 – 12.7 mm) single layer locked vs. 10.8 (8.1 – 12.8 mm) double layer; (p = 0.84). At the time of the second follow-up, the uterine scar was not significantly (p = 0.06) thicker if the uterus had been closed with a double layer closure 7.3 (5.7 – 9.1 mm), compared to single layer unlocked 6.4 (5.0 – 8.8 mm) or locked suturing techniques 6.8 (5.2 – 8.7 mm). Women who underwent primary or elective Cesarean delivery showed a significantly (p = 0.03, p = 0.02, “as treated”) increased median scar thickness after double layer closure vs. single layer unlocked suture. Conclusion A double layer closure of the hysterotomy is associated with a thicker myometrium scar only in primary or elective Cesarean delivery patients.

Journal ArticleDOI
TL;DR: Eine experimentelle Studie an Ex-vivo-Schweinenieren zeigte erwartungsgemäß erhöhte Scherwellengeschwindigkeiten mit ansteigendem intrarenalen Druck, which wurde bei 33 Patienten kein relevanter Einfluss auf die duplexsonografisch erfassbaren Perfusionsparameter gefunden.
Abstract: Correspondence Dr. Karlheinz Seitz khseitz@mac.com Der Zauberberg hatte gerufen, aber das Echo war schwach. Gerade mal 21 orale Präsentationen (einschließlich US-Interventionen) wurden vorgestellt. Es ist anzunehmen, dass mangels Anmeldungen kein Beitrag abgelehnt wurde. So hatte man Mühe, die vereinzelten wissenschaftlichen Programmpunkte unter gefühlten 1000 Refresherkursen und sonstigen durchwegs exzellent gemachten Fortbildungsformaten in der riesigen Sonohöhle überhaupt zu finden. Nur 9 Beiträge genügten den Kriterien einer Studie. Unterschiedliche Messergebnisse mit Schallköpfen mit unterschiedlicher Frequenz desselben Herstellers [1] lassen ermessen, welch großes unbearbeitetes Feld in der Elastografie bei zunehmender Anwendung verschiedener Gerätetypen vor uns liegt. Zumal zu erwarten ist, dass die Elastografie im Screening von Lebererkrankungen wohl zunehmend generell und auch bei speziellen Indikationen eingesetzt werden wird. Dies wurde anhand von Patienten vor Stammzelltransplantation gezeigt [2]. CEUS an der Lunge ist für die Arbeitsgruppe von Görg eine Herausforderung. Sie analysierten Pleurabefunde mittels CEUS bei im CT nachgewiesenen zentralen Lungenembolien [3, 4] sowie dem seltenen pulmonaler Lymphombefall [5]. Interessant ist eine Pilotstudie zur Anwendung der HiFu-Therapie bei 13 Patienten mit inoperablem Pankreaskarzinom [6]. Die Maßnahme führte zu einer eindrücklichen Tumorverkleinerung und signifikanten Schmerzlinderung. Diese Studie wurde zwischenzeitich 2-mal publiziert, mit Sicherheit dürfenwir von Strunk und Kollegen weitere Untersuchungen mit Hi-Fu erwarten. Eine experimentelle Studie an Ex-vivo-Schweinenieren zeigte erwartungsgemäß erhöhte Scherwellengeschwindigkeiten mit ansteigendem intrarenalen Druck [7]. Nach renaler Denervation – einer mittlerweile verlassenen Methode zur Hochdrucktherapie – wurde bei 33 Patienten kein relevanter Einfluss auf die duplexsonografisch erfassbaren Perfusionsparameter gefunden [8]. Nichts Neues konnte von einer retrospektiven Studie durch Auszählen benigner fokaler Leberläsionen [9] erwartet werden. Fokale Minderverfettung, Zysten und Hämangiome führen, bemerkenswerterweise. Allerdings hat der Verfasser – vermutlich ein Doktorand – Schwierigkeiten mit den Grundrechnungsarten, denn die Summe der einzelnen Läsionen liegt deutlich über der angegebenen Gesamtprävalenz! Die zunehmendeVerbreitungder naturgemäßnicht absolut noninvasiven Endosonografie generiert eine geringe Komplikationsrate. Die Vorgehensweise bei Duodenalperforationen nach Endosonografiewurde anhand von 24 Fällen aufgezeigt [10]. Eine Fallserie zu Komplikationen von perkutanen Ernährungssonden [11] zeigt, dass hier die diagnostischen Möglichkeiten der Sonografie bei weitem nicht ausgeschöpft werden. Unter der RubrikWissenschaft liefen ferner 10 Case Reports, von denen die Mehrzahl Lehrbuchwissen darstellten, teils jedoch klinisch interessante Verläufe aufwiesen [12–19]. Selten, sehr typisch und für viele unbekannt, ist der Mucorbefall bei meist mehrfach chemotherapeutisch behandelten onkologischen Patienten, hier bei chronisch lymphatischer Leukämie in der CEUS nicht enhancenden Herden in Leber und Milz [20]. Ebenfalls im Verlauf einer onkologischen Therapie, die immer wieder für außergewöhnliche Komplikationen sorgen kann, ist die Beobachtung von Chloromen der Gallenblase und Gallenwege mit Infiltrationen durch eine akute myeloische Leukämie unter dem klinischen Bild einer akuten Cholezystitis [21]. Zusammenfassend lässt die Darstellung des wissenschaftlichen Teils des Dreiländertreffens im Bereich Innere Medizin, Radiologie, Urologie und Chirurgie auf einen Niedergang des wissenschaftlichen Ultraschall, in den drei am Kongress beteiligten Gesellschaften, erkennen. Die nachlassende Anzahl und Qualität der Beiträge ist seit Jahren zu beobachten und hat ein alarmierendes Stadium erreicht und wird sich sicherlich auch auf unsere Nachlese 421



Journal ArticleDOI
TL;DR: A high reliability to reproduce echogenicity values of the insula using digitized image analysis and TCS-MRI fusion images with almost perfect intra-reader, inter- reader, intra-Investigator and inter-investigator agreement is demonstrated.
Abstract: Purpose: Transcranial B-mode sonography (TCS) of brain parenchyma is increasingly used as a diagnostic tool for movement disorders. Accordingly, experimental B-Mode Assist software was developed to enable digitized analysis of the echogenicity of predefined brain regions. The aim of the study was to assess the reproducibility of digitized TCS image analysis of the insula. Materials and Methods: A total of 130 patients with an indication for neurosonological examination were screened for participation in the study. The insula was imaged from the right temporal bone window using Virtual Navigator and TCS-MRI (magnetic resonance imaging) fusion imaging. All subjects were examined three times by two experienced sonographers. Corresponding images of the insula in the axial thalamic plane were encoded and digitally analyzed. Interclass correlation coefficient (ICC) and Spearman’s rank correlation coefficient were used for the assessment of intra- and inter-reader as well as intra- and inter-investigator reliabilities. Results: TCS images of 114 patients were evaluated (21 patients with TIA, 53 patients with headache, 18 patients with essential tremor, 22 patients with neurodegerative disease). 16 patients were excluded from analysis due to insufficient bone window. The intra-reader, inter-reader, intra-investigator and inter-investigator ICCs/Spearman’s rank correlation coefficients were 0.995/0.993, 0.937/0.921, 0.969/0.961 and 0.875/0.858, resp. Conclusion: The present study demonstrates a high reliability to reproduce echogenicity values of the insula using digitized image analysis and TCS-MRI fusion images with almost perfect intra-reader, inter-reader, intra-investigator and inter-investigator agreement.

Journal ArticleDOI
TL;DR: The ability of HRUS to monitor disease activity and the effect of treatment in patients with leprosy reactions is demonstrated by determining changes in nerve size and vascularity, which are indicators of peripheral nerve involvement and damage.
Abstract: Purpose Early diagnosis and treatment of leprosy and leprosy reactions are essential to prevent stigmatizing deformities and disability. Although the incidence of leprosy has decreased enormously, grade 2 disability due to nerve injury has remained the same. New tools are needed to better diagnose and monitor leprosy reactions and associated neuritis and this study assessed whether high-resolution sonography (HRUS) can be used as such a tool. Materials and Methods During a prospective follow-up period of 2 years at regular intervals, we performed clinical examination to assess sensory and motor function and HRUS of the four main peripheral nerves in 57 patients, of whom 36 were with reactions and 21 were without reactions. Normative data of the cross-sectional area (CSA) of these nerves were obtained from 55 healthy subjects (HS). Color Doppler (CD) was used to study blood flow in the nerves. Results At the baseline visit and during follow-up, all four nerves were significantly thicker in patients with leprosy reactions in comparison to HS (p Conclusion This prospective study demonstrates the ability of HRUS to monitor disease activity and the effect of treatment in patients with leprosy reactions by determining changes in nerve size and vascularity, which are indicators of peripheral nerve involvement and damage.

Journal ArticleDOI
TL;DR: Vaginal ultrasound probes are semi-critical Group A medical products which must be disinfected following the manufacturer's instructions after every patient examination, and a fully-automatic disinfection system for ultrasound probes was introduced to the market in 2009.
Abstract: Vaginal ultrasound probes are semi-critical Group A medical products which must be disinfected following the manufacturer’s instructions after every patient examination 1 2 . According to the “Essential Requirements for Medical Devices (Directive 93/42/EEC, Annex I, paragraph 13)” 3 the manufacturer’s instructions for use for reusable products must contain suitable instructions for preparation processes. This presumes both an effective and material-compatible method. Evidence of effectiveness must be validated. In the Editorial in issue 1 Ultraschall in der Medizin/European Journal of Ultrasound 2005 we discussed the topic of transducer hygiene and stated that proper handling and cleaning as well as disinfection of probes in daily use are indispensable 4 . This applies particularly to vaginal ultrasound probes routinely used in gynecological and obstetrical clinics, gynecological practices as well as IVF centers Normally the probe used in a transvaginal ultrasound examination is covered with a latex protective cover (with CE marking 2 ) which contains a certain amount of ultrasound gel. After the examination, the cover is removed and disposed of, and the gel is removed from the transducer. Since handling of the probe, ultrasound gel and cover can result in smear infections and cross-contamination with various pathogens (e. g. MRSA, HBV, HCV, HIV, herpes papilloma and cytomegalic viruses) 3 5 6 , after the protective cover is removed, the probe must be cleaned and subjected to disinfection with a bactericidal, fungicidal and virucidal effect 7 8 9 . This is especially important in the event the cover ruptures during the vaginal examination, and the probe comes into direct contact with vaginal secretions or blood. The same likewise applies if the sterile protective cover is perforated during a follicular puncture 10 . Usually special bactericidal, levurocidal and virucidal wipes or special submersion disinfection methods are available for disinfecting the vaginal ultrasound probes 11 . Using special virucidal wipes on the probes is considered low-level disinfection. Primarily quaternary ammonia compounds are employed for this procedure. This method is easily applicable, has good cleaning characteristics, is effective against HPV and has high skin tolerance. However, it has the disadvantage of not removing all microorganisms during the disinfection process 6 12 . Immersion procedures are high-level disinfection methods during which the transducer head is dipped in a special fluid for a certain amount of time. The disinfectants used for this include e. g. preparations based on glutaraldehyde or succinic aldehyde. However, in practice immersion disinfection has a number of disadvantages 13 : 1. The procedure cannot be validated. 2. The probe permanently attached to the device must be placed in a separate holder and disinfected for at least 15 minutes. This is impracticable in routine operations in a clinic, outpatient facility or practice with a high number of examinations. 3. After this disinfection method, the probe has to be thoroughly rinsed with potable or higher-quality water in order to remove remnants of allergenic or locally toxic substances. 4. Frequently examinations take place in small interior areas with poor ventilation, thus under some circumstances posing an inhalant-related health hazard. 5. The required virucidal effect is frequently not achieved within 15 minutes 13 . Furthermore, extended probe contact with liquid disinfecting agents in the long run results in increased wear of the transducer head membrane. Therefore it was interesting to note that in 2009 a fully-automatic disinfection system for ultrasound probes was introduced to the market (Trophon ® EPR). This product, developed in Australia, promised relatively rapid high-level disinfection (HLD). During this software-controlled, mechanical disinfection procedure, the entire ultrasound probe (transducer head and handle) is placed in a sealed disinfection chamber, then hydrogen peroxide (H 2 O 2 ) is discharged as an anti-microbial aerosol into the closed chamber. The ultra-fine mist wets the entire surface of the probe with H 2 O 2 , thereby achieving high-level disinfection of the entire ultrasound probe. At the end of the process, a catalytic decomposition system breaks down the H 2 O 2 into environmentally-friendly oxygen and water. When the chamber is opened, the probe is dry and ready for immediate use. The fully-automatic device was designed as a table unit to be placed directly next to the ultrasound equipment so that the probe does not need to be disconnected from the base unit. The entire disinfection process lasts 7 minutes: 2 minutes for the application and 5 minutes to remove the aerosol residue. In a validation study using carrier tests, Heeg and Gauer in 2014 15 showed that this procedure genuinely achieved HLD of ultrasound probes within 7 minutes, thus making it suitable for daily clinical routine. The procedure fulfills all requirements for HLD based on the medical device classification according to the legally-prescribed recommendation of the Commission for Hospital Hygiene and Prevention of Infection and the Federal Institute for Drugs and Medical Products (KRINKO/BfArM) 8 9 in Germany. In the USA, this method was approved by the FDA as well as the leading probe manufacturers, and bears the testing certificate of the German Society for Hospital Hygiene (DGKH). All in all, it should be stated that the sole use of a latex protective cover when using a vaginal probe does not meet the necessary standard of care required for the provision of semi-critical medical products according to the joint recommendation of the German Federal Institute for Drugs and Medical Products (BfArM) and Commission for Hospital Hygiene and Prevention of Infection of the Robert Koch Institute, and constitutes a contravention of necessary patient and user protections 9 . Use of the protective cover does not rule out smear infections and cross-contamination; therefore after each examination, the probe, after removal of the cover, must undergo disinfection measures providing bactericidal, fungicidal and virucidal effects 9 . Since the transducer handle also poses a significant risk of transmission of germs 6 , this component must likewise be sufficiently disinfected. In the event of perforation or rupture of the latex cover, thus resulting in the probe coming into contact with vaginal secretions or blood, the probe must be not only cleaned, but effectively disinfected with a virucide as well 13 . It should also be noted that infection by bacteria and viruses can be caused not only by a contaminated probe, but by the ultrasound gel as well 14 . According to studies by Heeg and Gauer 15 , Buescher et al. 6 as well as Ryndock et al. 16 , the fully automatic HLD system operated with hydrogen peroxide is currently the only validated system proven to provide HLD of ultrasound probes in a 7-minute cycle, thus suitable for application in the daily routine. Likewise it can also be presumed that this procedure also offers good material compatibility.

Journal ArticleDOI
TL;DR: Since intrauterine MRI has been becoming increasingly important in recent years, it is necessary to determine when MRI is indicated and there is general consensus in the literature that MRI is not a screening method for detecting fetal anomalies but should be viewed as a supplementary method to ultrasound.
Abstract: Both in routine diagnostics and detailed, highly specialized workups, major advances have been observed in many areas of ultrasound due to an increase in expertise and improved technology in recent years. This is particularly true in the case of fetal neurosonography 1 2 3 4 . Malformations of the CNS together with fetal heart defects are among the most common congenital anomalies. From the embryonic phase to the late third trimester, the CNS undergoes extensive development and maturation processes. The diagnosis of CNS anomalies is therefore primarily dependent on the time at which the examination is performed and the experience of the examiner. The introduction of transvaginal and 3 D ultrasound for evaluating fetal brain structures has made it possible to diagnose pathological findings of the CNS with increasing accuracy 5 . The detection rates for CNS anomalies are up to 90 – 95 % depending on the finding 3 5 . Today, detailed fetal neurosonography also includes differential diagnostic evaluation of the posterior cranial fossa, the corpus callosum (CC), and the gyri and therefore exceeds the primarily conspicuous, non-specific diagnosis of “ventricular dilation“ often occurring as an accompanying symptom 6 7 The article “Prenatal Diagnosis of Corpus Callosum Anomalies“ appearing in this issue shows an increase in the frequency of diagnosis and also shows that it is possible to differentiate between complete and partial corpus callosum agenesis and hypoplasia of the corpus callosum with differentiation between isolated and non-isolated cases is possible on ultrasound. In 4 of 44 cases in which both neurosonography and intrauterine MRI were performed, there was a discrepancy between the ultrasound diagnosis and the intrauterine MRI findings. In a comparison of the sonographic diagnoses and the MRI findings, additional pathologies were seen on MRI but not on ultrasound in only 3 of 44 cases. In a further case of CC hypoplasia, the sonographic diagnosis was superior to the MRI findings. Another study appearing in this issue study of CNS anomalies in fetuses with complex clubfoot also showed additionally diagnosed CNS anomalies in 4 cases on MRI. MRI yielded supplementary findings that were not visible on ultrasound in 6 cases. Although the number of cases is small, it was able to be shown, as in other studies, that a certain percentage of CNS anomalies is able to be evaluated on an additional or supplementary basis on MRI. Since intrauterine MRI has been becoming increasingly important in recent years, it is necessary to determine when MRI is indicated. There is general consensus in the literature that MRI is not a screening method for detecting fetal anomalies but should be viewed as a supplementary method to ultrasound 8 9 10 . However, MRI application in pregnancy is increasing. Intrauterine MRI is most commonly used in the case of abnormal ultrasound findings regarding the CNS 11 12 13 . This includes morphological evaluation of malformations and recently also of acquired hypoxic-ischemic diseases, bleeding and inflammation such as CMV infections. Thoracic and abdominal malformations are also indications for MRI for the evaluation of the lung volume in diaphragmatic defects and in the case of suspicion of esophageal atresia abnormal placentation. Further possible indications for the use of MRI include monochorial multiple pregnancies with a feto-fetal transfusion syndrome (for the evaluation of neurological development) and select cases with known diseases and syndromes 14 . The majority of studies for comparing intrauterine MRI to sonographic diagnosis include a small number of cases with limited or no follow-up. Data regarding sensitivities, specificities, and positive predictive values is limited. Many studies simply calculate the difference in percentages on the basis of a small number of cases. The best available data is in regard to CNS anomalies. In one of the few meta-analyses including 34 studies and documented follow-up in 959 fetuses, intrauterine MRI was correct in 91 % of cases which was an increase of 16 % above that achieved by ultrasound 15 . This means a significant diagnostic gain for specific issues. However, it must be taken into consideration that the analysis includes a period of 20 years and fetal neurosonography has made major progress in this time. The diagnostic gain would tend to be smaller today. In many studies the level of experience of the ultrasound examiners often remains unclear A possible bias is also that an examiner with less experience determines an indication for intrauterine MRI faster and more frequently and can thus gain more information compared to highly specialized, experienced ultrasound examiners in prenatal centers. Since advanced training in prenatal diagnosis is becoming increasingly difficult due to the transfer of centers to ambulatory practices, there is a certain risk that crash courses or brief internships in ultrasound will result in intrauterine MRI playing an additional role in fetal differential diagnosis and in the confirmation of findings. Because intrauterine MRI is stressful for pregnant women, indiscriminate indication for MRI cannot be recommended even if no fetal damage is to be expected provided that the appropriate safety measures are observed (examination duration of approx. 30 minutes and implementation of MRI after 18 weeks of gestation). After a properly performed ultrasound examination, little additional morphological information can be gained from MRI 16 . However, in the case of an unclear sonographic finding or in the event of therapeutic consequences for the care of the fetus or for the birth, MRI is an excellent supplementary method to ultrasound. Concretely, this means ultrasound first. If the finding is not clear, intrauterine MRI can be used as an adjunct method. In this way the cost-benefit ratio can be optimized. The gains achieved by MRI compared to US depend on the quality of the examination and thus on the expertise of the examiner in both methods. The indications for fetal MRI should also follow defined standards based on a protocol adapted to the particular clinical issue 16 .

Journal ArticleDOI
TL;DR: In this paper, structural transcranial ultrasound (TCS) was used to visualize and measure the medial temporal lobe (MTL) and compared the results of 32 AD patients and 84 healthy controls (HC).
Abstract: Purpose One of the anatomical hallmarks of Alzheimer’s disease (AD) is the atrophy of the medial temporal lobe (MTL), yet cost-effective and broadly available methodological alternatives to the current imaging tools for screening of this brain area are not currently available. Materials and Methods Using structural transcranial ultrasound (TCS), we attempted to visualize and measure the MTL, and compared the results of 32 AD patients and 84 healthy controls (HC). The MTL and the surrounding space were defined in the coronal plane on TCS. A ratio of the height of the MTL/height of the choroidal fissure (M/F) was calculated in order to obtain a regional proportion. Results An insufficient temporal bone window was identified in 22 % of the AD patients and 12 % of the HCs. The results showed that the ratio of M/F was significantly smaller in the AD group on both sides (p = 0.004 right, p = 0.007 left side). Furthermore, the M/F ratio made it possible to discriminate AD patients from HCs with a sensitivity of 83 % (right)/73 % (left) and a specificity of 76 % (right)/72 % (left) which is basically comparable to results published for magnetic resonance imaging. The measurements showed substantial intra/interrater reliability (ICC:0.79/0.69). Conclusion These results suggest that utilization of structural TCS may possibly constitute a cheap and easy-to-use supplement to other techniques for the diagnosis of AD. It may be especially useful as a screening tool in the large population of individuals with cognitive decline. Further studies are needed to validate this novel method.

Journal ArticleDOI
TL;DR: In most cases, fetal cataract was associated with additional abnormalities, both intra- and extra-ocular, and in instances when cataracts are isolated, it is suggested conducting a detailed and thorough in utero ophthalmic examination in order to improve antenatal parental counselling.
Abstract: Purpose To report and review our experience with antenatal evaluation for fetuses diagnosed with congenital cataract. Materials and Methods We retrospectively identified pregnancies diagnosed with fetal cataract during antenatal ultrasound. Evaluation of fetal eyes included intraocular anatomy and biometry. Data on fetal malformations, serology and fetal karyotype were collected. Results 8 cases, identified over the course of 10 years, were reviewed. Week 15 was the mean time for diagnosis (range 11 – 34). Extraocular anomalies were demonstrated in 6 cases (central nervous system, cardiac and renal systems). Additional intraocular abnormalities were detected in two cases: one fetus had persistent hyperplastic primary vitreous and another had bilateral retinal detachment. All cases but one involved cataracts in both eyes. The unilateral case was associated with microphthalmic aphakia. All cases had negative serology for TORCHs. 7 out of the 8 fetuses were terminated. The only one who survived developed in utero cataracts secondary to maternal steroid therapy. He underwent bilateral cataract extraction during the first weeks of life and ophthalmologic evaluation at 2 years of age was unremarkable, without any visual impairment. Conclusion In most cases, fetal cataract was associated with additional abnormalities, both intra- and extra-ocular. In instances when cataracts are isolated, we suggest conducting a detailed and thorough in utero ophthalmic examination in order to improve antenatal parental counselling.

Journal ArticleDOI
TL;DR: Maternal ophthalmic artery Doppler did not promote a significant increase in the PE detection rate during the second trimester scan, and the best model for the prediction of PE was determined.
Abstract: Purpose To establish the performance of a multi-parametric test including maternal risk factors and maternal uterine and ophthalmic artery Doppler in the second trimester of pregnancy for the prediction of preeclampsia (PE). Materials and Methods We performed a prospective observational cohort study with pregnant women who underwent a second trimester morphology scan. Maternal uterine and ophthalmic artery Doppler examinations were performed in 415 singleton pregnancies between 18 and 23 weeks of gestation. Additional history was obtained through participant questionnaires, and follow-up occurred to the time of discharge post-delivery. The control and PE groups were compared to continuous variables using the Kruskal-Wallis test and to categorical variables using the Chi-square and Fisher exact tests. Univariate and multivariate logistic regression analyses were performed to determine the best model for the prediction of PE. Results 40 (9.6 %) pregnant women developed PE. We observed significant differences in the body mass index (BMI) (p Conclusion Maternal ophthalmic artery Doppler did not promote a significant increase in the PE detection rate during the second trimester scan.

Journal ArticleDOI
TL;DR: Strain elastography is correlated to fibrosis in lymph nodes and a significant difference was observed on a group level using the strain ratio, and individual mesenteric lymph nodes could not be identified accurately as metastatic or not by strain imaging alone.
Abstract: Purpose: To investigate if strain elastography could differentiate between metastatic and non-metastatic mesenteric lymph nodes ex-vivo. Materials and Methods: 90 mesenteric lymph nodes were examined shortly after resection from 25 patients including 17 patients with colorectal cancer and 8 patients with Crohn’s disease. Ultrasound-based strain elastography was performed with a linear probe. Tissue hardness in lymph nodes was assessed using visual scales and measuring the strain ratio. B-mode characteristics were also recorded. Pathological diagnosis with grading of fibrosis served as the reference standard. Results: 20 lymph nodes were metastatic and 70 lymph nodes were non-metastatic. The strain ratios of metastatic and non-metastatic lymph nodes were significantly different (1.83 vs. 1.42, p = 0.021). The VAS scale (0 – 100) for tissue hardness gave higher mean values for metastatic than non-metastatic nodes, but the difference was not significant (65.5 vs. 55.0, p = 0.055). There was no difference between lymph nodes in Crohn’s and non-metastatic cancer specimens. The metastatic lymph nodes were significantly more fibrotic than the non-metastatic lymph nodes by the ordinal fibrosis score (0 – 3). In an ROC analysis, quantitative strain imaging was not superior to the measurement of the short-axis diameter of lymph nodes in differentiating metastatic from non-metastatic mesenteric lymph nodes ex-vivo. Conclusion: Strain elastography is correlated to fibrosis in lymph nodes and a significant difference was observed on a group level using the strain ratio. Due to measurement overlap, individual mesenteric lymph nodes could not be identified accurately as metastatic or not in this ex-vivo model by strain imaging alone.