Arterial compliance probe for cuffless evaluation of carotid pulse pressure

TLDR
This technique could provide a direct measurement of local PWV, arterial dimensions, and a calibration-free estimate of beat-by-beat local ΔP, and can be potentially extended for cuffless BP measurement and non-invasive characterization of central arteries with locally estimated biomechanical properties.
Abstract
Objective Assessment of local arterial properties has become increasingly important in cardiovascular research as well as in clinical domains. Vascular wall stiffness indices are related to local pulse pressure (ΔP) level, mechanical and geometrical characteristics of the arterial vessel. Non-invasive evaluation of local ΔP from the central arteries (aorta and carotid) is not straightforward in a non-specialist clinical setting. In this work, we present a method and system for real-time and beat-by-beat evaluation of local ΔP from superficial arteries—a non-invasive, cuffless and calibration-free technique. Methods The proposed technique uses a bi-modal arterial compliance probe which consisted of two identical magnetic plethysmograph (MPG) sensors located at 23 mm distance apart and a single-element ultrasound transducer. Simultaneously measured local pulse wave velocity (PWV) and arterial dimensions were used in a mathematical model for calibration-free evaluation of local ΔP. The proposed approach was initially verified using an arterial flow phantom, with invasive pressure catheter as the reference device. The developed porotype device was validated on 22 normotensive human subjects (age = 24.5 ± 4 years). Two independent measurements of local ΔP from the carotid artery were made during physically relaxed and post-exercise condition. Results Phantom-based verification study yielded a correlation coefficient (r) of 0.93 (p < 0.001) for estimated ΔP versus reference brachial ΔP, with a non-significant bias and standard deviation of error equal to 1.11 mmHg and ±1.97 mmHg respectively. The ability of the developed system to acquire high-fidelity waveforms (dual MPG signals and ultrasound echoes from proximal and distal arterial walls) from the carotid artery was demonstrated by the in-vivo validation study. The group average beat-to-beat variation in measured carotid local PWV, arterial diameter parameters—distension and end-diastolic diameter, and local ΔP were 4.2%, 2.6%, 3.3%, and 10.2% respectively in physically relaxed condition. Consistent with the physiological phenomenon, local ΔP measured from the carotid artery of young populations was, on an average, 22 mmHg lower than the reference ΔP obtained from the brachial artery. Like the reference brachial blood pressure (BP) monitor, the developed prototype device reliably captured variations in carotid local ΔP induced by an external intervention. Conclusion This technique could provide a direct measurement of local PWV, arterial dimensions, and a calibration-free estimate of beat-by-beat local ΔP. It can be potentially extended for calibration-free cuffless BP measurement and non-invasive characterization of central arteries with locally estimated biomechanical properties.

read more

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI

Bi-Modal Arterial Compliance Probe for Calibration-Free Cuffless Blood Pressure Estimation

TL;DR: The feasibility of calibration-free, cuffless BP measurement at an arterial site of interest was demonstrated with a level of acceptable accuracy and the potential utility of the proposed method and system in hypertension screening and local evaluation of arterial stiffness indices was demonstrated.
Journal ArticleDOI

Current understanding of intimal hyperplasia and effect of compliance in synthetic small diameter vascular grafts.

TL;DR: This review aims to explain the biomechanical factors that are responsible for the formation and development of IH and their relationship with compliance mismatch and address the current methods used to measure compliance both in vitro and in vivo.
Journal ArticleDOI

Cuffless Blood Pressure Measurement.

TL;DR: Cuffless blood pressure (BP) measurement has become a popular field due to clinical need and technological opportunity as discussed by the authors , and recent technological advances, including smartphone proliferation and wearable sensing, that are driving the field.
Journal ArticleDOI

High-frame-rate A-mode ultrasound for calibration-free cuffless carotid pressure: feasibility study using lower body negative pressure intervention

TL;DR: The study demonstrated the high-frame-rate ultrasound technology's potential for providing cuffless and calibration-free pressure measurements while reliably capturing the physiological aspects, such as PP amplification and dynamic pressure responses to intervention.
References
More filters
Journal ArticleDOI

Hemodynamic Patterns of Age-Related Changes in Blood Pressure: The Framingham Heart Study

TL;DR: The late fall in DBP after age 60 years, associated with a continual rise in SBP, cannot be explained by "burned out" diastolic hypertension or by "selective survivorship" but is consistent with increased large artery stiffness.
Journal ArticleDOI

Differential impact of blood pressure-lowering drugs on central aortic pressure and clinical outcomes: principal results of the Conduit Artery Function Evaluation (CAFE) study.

TL;DR: The CAFE study as mentioned in this paper examined the impact of two different BP lowering-regimens (atenolol±thiazide-based versus amlodipine±perindopril-based) on derived central aortic pressures and hemodynamics.
Journal ArticleDOI

Blood pressure and incidence of twelve cardiovascular diseases: lifetime risks, healthy life-years lost, and age-specific associations in 1·25 million people.

TL;DR: The widely held assumptions that blood pressure has strong associations with the occurrence of all cardiovascular diseases across a wide age range, and that diastolic and systolic associations are concordant, are not supported by the findings of this high-resolution study.
Journal ArticleDOI

Central pressure more strongly relates to vascular disease and outcome than does brachial pressure: the Strong Heart Study.

TL;DR: Noninvasively-determined central pulse pressure is more strongly related to vascular hypertrophy, extent of atherosclerosis, and cardiovascular events than is brachial blood pressure, and these findings support prospective examination of use of central blood pressure as a treatment target in future trials.
Journal ArticleDOI

Pulse pressure—a review of mechanisms and clinical relevance

TL;DR: The origin, clinical relevance and treatment of pulse pressure is reviewed, and a distributed compliance model of the arterial circulation provides a framework for understanding the causes, effects and potential treatment of elevations in PP.
Related Papers (5)