Journal ArticleDOI
Clean analytical methodology for the determination of lead with Arsenazo III by cyclic flow-injection analysis.
TLDR
A clean analytical methodology, where the sample determined and the reagent used are both toxic, has been proposed, which provides a satisfactory way to cut down on the toxic reagent consumption and the produced volume of waste.About:
This article is published in Talanta.The article was published on 2005-12-15. It has received 23 citations till now. The article focuses on the topics: Reagent & Arsenazo III.read more
Citations
More filters
Journal ArticleDOI
Green Analytical Chemistry
TL;DR: In this paper, the origins and the fundamentals of green analytical chemistry (GAC) are discussed, and the strategies and the tools available to make sample-pretreatment and analytical methods greener.
Journal ArticleDOI
Green analytical methodologies.
Journal ArticleDOI
Green chemistry and the evolution of flow analysis. A review.
TL;DR: The evolution of flow analysis towards green analytical chemistry is demonstrated by comparing classical procedures implemented with different flow approaches, and the ability to implement processes unreliable in batch to replace toxic chemicals is emphasized.
Journal ArticleDOI
Dithiocarbamate functionalized or surface sorbed Merrifield resin beads as column materials for on line flow injection–flame atomic absorption spectrometry determination of lead
TL;DR: The developed on-line FI-FAAS procedure employing dithiocarbamate functionalized MCR beads as column material has been successfully tested for the analysis of surface, pond, ground and effluent water and soil samples collected from the vicinity of lead acid battery industry in India.
Journal ArticleDOI
Flow Analysis: A Novel Approach For Classification.
Christina Vakh,Marina T. Falkova,Irina Timofeeva,A. L. Moskvin,Leonid Moskvin,Andrey Bulatov +5 more
TL;DR: A novel approach for classification of flow analysis methods according to the conditions under which the mass transfer processes and chemical reactions take place in the flow mode: dispersion-convection flow methods and forced-conventus flow methods are suggested.
References
More filters
Journal ArticleDOI
Flow Injection Analysis
J. Růžička,J.W.B. Stewart +1 more
TL;DR: In this paper, the effect of sample volume, tube length, tube diameter, peak height and sampling rate on the determination of phosphorus in acidic plant digests was investigated, and optimal conditions for the flow injection method were described.
Journal ArticleDOI
Flow Injection Analysis
TL;DR: This paper presents a meta-review of the Flow--Injection Literature and discusses theoretical Aspects of FIA Techniques, components of An FIA Apparatus, and Experimental Techniques and FIA Exercises.
Book
Introduction to Environmental Toxicology
Wayne G. Landis,Ming-Ho Yu +1 more
TL;DR: Introduction to environmental toxicology , Introduction to environmental Toxicology , کتابخانه دیجیتال جندی شاپور اهواز
Journal ArticleDOI
Ion-exchanger colorimetry-I Micro determination of chromium, iron, copper and cobalt in water.
TL;DR: A new sensitive, colorimetric method based on the direct measurement of light-absorption by an ion-exchange resin phase, which has sorbed the sample complex species, has been developed and determinations ofchromium(VI) with diphenylearbazide, iron(II) with 1,10-phenanthroline, copper with Zincon and cobalt with thiocyanate have more than ten times the sensitivity obtainable with conventional solution colorimetry.