Correcting astigmatism with toric intraocular lenses: Effect of posterior corneal astigmatism

TLDR
Corneal astigmatism was overestimated in WTR by all devices and underestimated in ATR by all except the Placido–dual Scheimpflug analyzer.
Abstract
Purpose To evaluate the impact of posterior corneal astigmatism on outcomes with toric intraocular lenses (IOLs). Setting Cullen Eye Institute, Baylor College of Medicine, Houston, Texas, USA. Design Case series. Methods Corneal astigmatism was measured using 5 devices before and 3 weeks after cataract surgery. Toric IOL alignment was recorded at surgery and at the slitlamp 3 weeks postoperatively. The actual corneal astigmatism was calculated based on refractive astigmatism 3 weeks postoperatively and the effective toric power calculated with the Holladay 2 formula. The prediction error was calculated as the difference between the astigmatism measured by each device and the actual corneal astigmatism. Vector analysis was used in all calculations. Results With the IOLMaster, Lenstar, Atlas, manual keratometer, and Galilei (combined Placido–dual Scheimpflug analyzer), the mean prediction errors (D) were, respectively, 0.59 @ 89.7, 0.48 @ 91.2, 0.51 @ 78.7, 0.62 @ 97.2, and 0.57 @ 93.9 for with-the-rule (WTR) astigmatism (60 to 120 degrees), and 0.17 @ 86.2, 0.23 @ 77.7, 0.23 @ 91.4, 0.41 @ 58.4, and 0.12 @ 7.3 for against-the-rule (ATR) astigmatism (0 to 30 degrees and 150 to 180 degrees). In the WTR eyes, there were significant WTR prediction errors (0.5 to 0.6 diopters [D]) by all devices. In ATR eyes, WTR prediction errors were 0.2 to 0.3 D by all devices except the Placido–dual Scheimpflug analyzer (all P Conclusions Corneal astigmatism was overestimated in WTR by all devices and underestimated in ATR by all except the Placido–dual Scheimpflug analyzer. A new toric IOL nomogram is proposed. Financial Disclosure Drs. Koch, Weikert, and Wang received research support from Ziemer USA, Inc. Dr. Koch has a financial interest with Alcon Laboratories, Inc., Abbott Medical Optics, Inc., Optimedica Corp., and Ziemer USA, Inc. No other author has a financial or proprietary interest in any material or method mentioned.

read more

Citations
More filters
Journal ArticleDOI

Microincision cataract surgery with implantation of a bitoric intraocular lens using an enhanced program for intraocular lens power calculation

TL;DR: The use of an optimized software for toric intraocular lens power calculation, considering the contribution of posterior corneal astigmatism, improved the astigmatic outcome with a bitoric intraocular Lens AT TORBI 709M.
Journal ArticleDOI

Prevention method of toric intraocular lens rotation after phacoemulsification of cataract using a standard capsule ring

TL;DR: Developed a method of preventing the rotation of the toric intraocular lens using a standard capsule ring, which is implanted and located on top of the haptic support elements of the artificial lens can increase the efficiency of phacoemulsification of cataracts in the eyes with corneal astigmatism.
Journal ArticleDOI

Accuracy of the Goggin Nomogram for 0.50 D Steps in Toric IOL Cylinder Power Calculation.

TL;DR: Goggin Nomogram adjusted keratometry provided optimal refractive astigmatic outcome in IOL cylinder powers of 1.00 to 3.00 D in eyes with with-the-rule, against the rule, and oblique astigmatism.
Journal ArticleDOI

Visual Outcome of Phacoemulsification with Multifocal Toric Intraocular Lens Implantation in “With the Rule” and “Against the Rule” Corneal Astigmatism: A Case Series

TL;DR: Phacoemulsification with implantation of multifocal toric intraocular lens (IOL) is now a well-established modality to treat cataract and corneal astigmatism in a single surgical procedure and the visual outcome has been deliberated in corneas with preexisting With the Rule (WTR) and Against the rule (ATR)Astigmatism.
References
More filters
Journal ArticleDOI

Contribution of posterior corneal astigmatism to total corneal astigmatism.

TL;DR: Selecting toric intraocular lenses based on anterior corneal measurements could lead to overcor correction in eyes that have with‐the‐rule astigmatism and undercorrection in eyes which have against‐the-ruleAstigmatism.
Journal ArticleDOI

The shape of the anterior and posterior surface of the aging human cornea.

TL;DR: The shape of the anterior corneal surface provides no definitive basis for knowing the asphericity of the posterior surface and the results show the effective refractive index is 1.329, which is lower than values commonly used.
Journal ArticleDOI

Analysis of aggregate surgically induced refractive change, prediction error, and intraocular astigmatism

TL;DR: Analytical methods for evaluating the results of keratorefractive surgical procedures and emphasize the importance of intraocular astigmatism and the limitations of manual keratometry are demonstrated.
Journal ArticleDOI

Foldable toric intraocular lens for astigmatism correction in cataract patients.

TL;DR: The results indicate that phacoemulsification and posterior chamber AcrySof toric IOL implantation is an effective option to correct preexisting astigmatism in cataract surgery.