scispace - formally typeset
Open AccessJournal ArticleDOI

Detection of coronary artery disease with perfusion stress echocardiography using a novel ultrasound imaging agent: two Phase 3 international trials in comparison with radionuclide perfusion imaging

Reads0
Chats0
TLDR
Imagify PSE was well-tolerated and its diagnostic performance in chest pain patients is comparable with SPECT perfusion imaging, which was equal for both modalities.
Abstract
Aims To determine if perfusion stress echocardiography (PSE) with Imagify™ (perflubutane polymer microspheres) is comparable to stress perfusion imaging using 99mTc single photon emission computed tomography (SPECT) for coronary artery disease (CAD) detection. PSE is a novel technique for evaluating myocardial perfusion. RAMP (real-time assessment of myocardial perfusion)-1 and -2 were international, Phase 3 trials that evaluated the ability of PSE with Imagify, to detect CAD. Methods and results Chronic, stable, chest pain patients ( n = 662) underwent Imagify PSE and gated SPECT imaging at rest and during dipyridamole stress. Independent blinded cardiologists [three PSE readers per trial, and four SPECT readers (one for RAMP-1, three for RAMP-2)] interpreted images. CAD was defined by quantitative coronary angiography or 90-day outcome with clinical review. Accuracy, sensitivity, and specificity were evaluated using non-inferiority analysis (one-sided alpha = 0.025) compared with SPECT. SPECT results for RAMP-1 and -2 were: accuracy (70%, 67%), sensitivity (78%, 61%), and specificity (64%, 76%). Accuracy of all six PSE readers was non-inferior to SPECT (66–71%, P ≤ 0.004). Four demonstrated non-inferior sensitivity (68–77%, P ≤ 0.002), three demonstrated non-inferior specificity (72–88%, P ≤ 0.013). Three PSE readers (RAMP-2) were superior for sensitivity. Two PSE readers (RAMP-1) were superior for specificity. Area under the multi-reader receiver operating characteristics curve (0.72) was equal for both modalities. Majority of adverse events followed dipyridamole dosing, and were mild, transient, and required no treatment. Conclusions Imagify PSE was well-tolerated. Its diagnostic performance in chest pain patients is comparable with SPECT perfusion imaging.

read more

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI

Contrast echocardiography: evidence-based recommendations by European Association of Echocardiography.

TL;DR: Based on the evidence, recommendations are proposed for the clinical use of contrast echocardiography, both for improving assessment of left ventricular structure and function compared with unenhanced echOCardiography and for the identification of myocardial perfusion.
Journal ArticleDOI

Imaging of perfusion using ultrasound

TL;DR: The dynamic contrast-enhanced ultrasound (DCE-US) as discussed by the authors has been used for monitoring the vascular response of tumour response to antivascular drugs in both diffuse and focal diseases and for the kidney.
Journal ArticleDOI

Microbubbles as Ultrasound Contrast Agents for Molecular Imaging: Preparation and Application

TL;DR: Microbubbles are used for contrast ultrasound imaging as blood-pool agents in cardiology and radiology and their promise as targeted agents for molecular imaging is now being recognized.
References
More filters
Journal ArticleDOI

Tissue Doppler imaging - A new prognosticator for cardiovascular diseases

TL;DR: Tissue Doppler imaging and derived deformation parameters improve prognostic assessment during dobutamine stress echocardiography and are associated with lower mortality rate or myocardial infarction and is superior to the wall motion score.