Diffusion-prepared stimulated-echo turbo spin echo (DPsti-TSE): An eddy current-insensitive sequence for three-dimensional high-resolution and undistorted diffusion-weighted imaging.

Reads0
Chats0
TLDR
It is shown that DPsti‐TSE can serve as a robust 3D diffusion‐weighted sequence and is an attractive alternative to the traditional two‐dimensional DW‐EPI approaches.
Abstract
In this study, we present a new three-dimensional (3D), diffusion-prepared turbo spin echo sequence based on a stimulated-echo read-out (DPsti-TSE) enabling high-resolution and undistorted diffusion-weighted imaging (DWI). A dephasing gradient in the diffusion preparation module and rephasing gradients in the turbo spin echo module create stimulated echoes, which prevent signal loss caused by eddy currents. Near to perfect agreement of apparent diffusion coefficient (ADC) values between DPsti-TSE and diffusion-weighted echo planar imaging (DW-EPI) was demonstrated in both phantom transient signal experiments and phantom imaging experiments. High-resolution and undistorted DPsti-TSE was demonstrated in vivo in prostate and carotid vessel wall. 3D whole-prostate DWI was achieved with four b values in only 6 min. Undistorted ADC maps of the prostate peripheral zone were obtained at low and high imaging resolutions with no change in mean ADC values [(1.60 ± 0.10) × 10−3 versus (1.60 ± 0.02) × 10−3 mm2/s]. High-resolution 3D DWI of the carotid vessel wall was achieved in 12 min, with consistent ADC values [(1.40 ± 0.23) × 10−3 mm2/s] across different subjects, as well as slice locations through the imaging volume. This study shows that DPsti-TSE can serve as a robust 3D diffusion-weighted sequence and is an attractive alternative to the traditional two-dimensional DW-EPI approaches.

read more

Citations
More filters
Journal ArticleDOI

Vessel wall characterization using quantitative MRI: what’s in a number?

TL;DR: A detailed introduction to novel quantitative MRI methods for measuring vessel wall dimensions, plaque composition and permeability, endothelial shear stress and wall stiffness shows the versatility of non-invasive quantitative MRI for probing vascular disease at several stages.
Journal ArticleDOI

Diffusion tensor imaging and arterial tissue: establishing the influence of arterial tissue microstructure on fractional anisotropy, mean diffusivity and tractography.

TL;DR: FA, MD and tractography were found to be highly sensitive to changes in the microstructural composition of arterial tissue, specifically pointing to cell, not collagen, content as the dominant source of the measured anisotropy in the vessel wall.
References
More filters
Journal ArticleDOI

Spin diffusion measurements : spin echoes in the presence of a time-dependent field gradient

TL;DR: In this article, a derivation of the effect of a time-dependent magnetic field gradient on the spin-echo experiment, particularly in the presence of spin diffusion, is given.
Journal ArticleDOI

Modified Spin‐Echo Method for Measuring Nuclear Relaxation Times

TL;DR: In this article, a spin echo method adapted to the measurement of long nuclear relaxation times (T2) in liquids is described, and the pulse sequence is identical to the one proposed by Carr and Purcell, but the rf of the successive pulses is coherent, and a phase shift of 90° is introduced in the first pulse.
Journal ArticleDOI

elastix : A Toolbox for Intensity-Based Medical Image Registration

TL;DR: The software consists of a collection of algorithms that are commonly used to solve medical image registration problems, and allows the user to quickly configure, test, and compare different registration methods for a specific application.
Journal ArticleDOI

Acute human stroke studied by whole brain echo planar diffusion‐weighted magnetic resonance imaging

TL;DR: Whole brain echo planar magnetic resonance imaging is used to identify and characterize diffusion abnormalities in acute cerebral ischemia and measures a unique physiological parameter that is sensitive to ischemic changes before conventional MRI, which has potential role in the quantitative study of human stroke pathophysiology and therapeutics.
Journal ArticleDOI

Artifacts and pitfalls in diffusion MRI.

TL;DR: In this article, specific problems that one may encounter when using MRI scanner gradient hardware for diffusion MRI, especially in terms of eddy currents and sensitivity to motion are reviewed.
Related Papers (5)