scispace - formally typeset
Open AccessJournal ArticleDOI

Recent developments in time-of-flight PET

TLDR
Recent developments in system design, image reconstruction, corrections, and the potential in new applications for TOF-PET are reviewed to introduce the reader in an educational way into the topic of time-of-flight-PET.
Abstract
While the first time-of-flight (TOF)-positron emission tomography (PET) systems were already built in the early 1980s, limited clinical studies were acquired on these scanners. PET was still a research tool, and the available TOF-PET systems were experimental. Due to a combination of low stopping power and limited spatial resolution (caused by limited light output of the scintillators), these systems could not compete with bismuth germanate (BGO)-based PET scanners. Developments on TOF system were limited for about a decade but started again around 2000. The combination of fast photomultipliers, scintillators with high density, modern electronics, and faster computing power for image reconstruction have made it possible to introduce this principle in clinical TOF-PET systems. This paper reviews recent developments in system design, image reconstruction, corrections, and the potential in new applications for TOF-PET. After explaining the basic principles of time-of-flight, the difficulties in detector technology and electronics to obtain a good and stable timing resolution are shortly explained. The available clinical systems and prototypes under development are described in detail. The development of this type of PET scanner also requires modified image reconstruction with accurate modeling and correction methods. The additional dimension introduced by the time difference motivates a shift from sinogram- to listmode-based reconstruction. This reconstruction is however rather slow and therefore rebinning techniques specific for TOF data have been proposed. The main motivation for TOF-PET remains the large potential for image quality improvement and more accurate quantification for a given number of counts. The gain is related to the ratio of object size and spatial extent of the TOF kernel and is therefore particularly relevant for heavy patients, where image quality degrades significantly due to increased attenuation (low counts) and high scatter fractions. The original calculations for the gain were based on analytical methods. Recent publications for iterative reconstruction have shown that it is difficult to quantify TOF gain into one factor. The gain depends on the measured distribution, the location within the object, and the count rate. In a clinical situation, the gain can be used to either increase the standardized uptake value (SUV) or reduce the image acquisition time or administered dose. The localized nature of the TOF kernel makes it possible to utilize local tomography reconstruction or to separate emission from transmission data. The introduction of TOF also improves the joint estimation of transmission and emission images from emission data only. TOF is also interesting for new applications of PET-like isotopes with low branching ratio for positron fraction. The local nature also reduces the need for fine angular sampling, which makes TOF interesting for limited angle situations like breast PET and online dose imaging in proton or hadron therapy. The aim of this review is to introduce the reader in an educational way into the topic of TOF-PET and to give an overview of the benefits and new opportunities in using this additional information.

read more

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI

State of the art in total body PET

TL;DR: The old concept of a total body PET scanner is seeing a clear revival and a large range of possible technical improvements seems to have the potential to change the current clinical routine and to expand the number of clinical applications of molecular imaging.
Journal ArticleDOI

Quantification, improvement, and harmonization of small lesion detection with state-of-the-art PET

TL;DR: New developments in positron emission tomography/computed tomography (PET/CT) include time-of-flight (TOF), point-spread-function (PSF), maximum-a-posteriori (MAP) based reconstruction, smaller voxels, respiratory gating, metal artefact reduction, and administration of quadratic weight-dependent 18F–fluorodeoxyglucose (FDG) activity are described.
Journal ArticleDOI

Performance Evaluation of the Vereos PET/CT System According to the NEMA NU2-2012 Standard

TL;DR: The overall performance characteristics of the Vereos PET/ CT system are comparable to state-of-the-art whole-body PET/CT systems with the exception that the peak NEC rate occurs at a higher activity concentration, thus indicating the ability of theVereosPET/CT system to cover a wider range of activities.
Journal ArticleDOI

PennPET Explorer: Design and Preliminary Performance of a Whole-Body Imager

TL;DR: The physical performance measurements validated the system design and led to high-quality human studies, and validation of lesion torso phantoms to characterize quantitative accuracy, human studies were performed on healthy volunteers.
References
More filters
Journal ArticleDOI

Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner

TL;DR: The performance of the Biograph mMR during independent and simultaneous acquisition of PET and morphologic MR data compares favorably with other state-of-the-art PET/CT and PET/MR scanners, indicating that the integration of the PET detectors in the MR scanner and their operation within the magnetic field do not have a perceptible impact on the overall performance.
Journal Article

Performance of Philips Gemini TF PET/CT Scanner with Special Consideration for Its Time-of-Flight Imaging Capabilities

TL;DR: The Gemini TF whole-body scanner represents the first commercially available fully 3-dimensional PET scanner that achieves time-of-flight capability as well as conventional imaging capabilities.
Journal ArticleDOI

Benefit of Time-of-Flight in PET: Experimental and Clinical Results

TL;DR: ToF leads to a better contrast-versus-noise trade-off than non-TOF but one that is difficult to quantify in terms of a simple sensitivity gain improvement.
Journal ArticleDOI

Physical and clinical performance of the mCT time-of-flight PET/CT scanner

TL;DR: The physical and clinical PET performance of the first Biograph mCT TOF PET/CT scanner (Siemens Medical Solutions USA, Inc.) in comparison with its predecessor, the Biograph TruePoint TrueV, is characterized and improvements with TOF are defined.
Journal ArticleDOI

Design and performance evaluation of a whole-body Ingenuity TF PET-MRI system

TL;DR: The results were comparable to PET-CT systems demonstrating that the effect of design modifications required on the PET system to remove the harmful effect of the magnetic field on the PMTs was negligible, and it is conceived that advantages of hybrid PET-MRI will become more evident in the near future.
Related Papers (5)