scispace - formally typeset
Search or ask a question
Institution

Vattenfall

CompanyStockholm, Sweden
About: Vattenfall is a company organization based out in Stockholm, Sweden. It is known for research contribution in the topics: Wind power & Combustion. The organization has 685 authors who have published 857 publications receiving 18912 citations. The organization is also known as: Vattenfall AB & Kungliga Vattenfallstyrelsen.


Papers
More filters
Journal ArticleDOI
TL;DR: This work proposes an innovative data quality management framework enabling asset managers to quantify the impact of poor data quality, and to determine the conditions under which an investment in data quality improvement is required.

18 citations

Journal ArticleDOI
Simon Hagemann1
TL;DR: In this article, the influence of power plant outages, forecast errors of wind and solar power production, load forecast errors and foreign demand and supply on intraday prices are explained from a theoretical perspective.
Abstract: This paper presents a first investigation of hourly price determinants in the German intraday market for electricity. The influence of power plant outages, forecast errors of wind and solar power production, load forecast errors and foreign demand and supply on intraday prices are explained from a theoretical perspective. Furthermore the influences of the non-linear merit-order shape, ramping costs and strategic market behavior are discussed. The empirical results from different regression analysis with data from 2010 and 2011 show that most price determinants increase and decrease intraday prices as expected. Nevertheless, only a minor share of power plant outages and solar power forecast errors are traded on the electronic intraday trading platform, thus influencing prices not as strongly as expected. Furthermore the price determinants influence intraday prices differently over the course of the day which may be explained by an alternating liquidity provision.

18 citations

DOI
01 Jan 2013
TL;DR: In this paper, the authors used a vertical and horizontal probe to measure the fraction of fly ash shedding at different stages of the shedding process and the integral deposit formation rate (IDF-rate).
Abstract: An increased use of biomass in large suspension-fired power plants can be a relatively economic and potentially also efficient way to utilize biomass for heat and power production. However, large deposit formation problems limit the electrical efficiency by limiting the maximum applicable superheater temperature, and the deposits may also cause boiler stops where different parts of the boiler have to be cleaned. This project aims at providing scientifically based knowledge on understanding of ash deposit formation and shedding in biomass suspension-fired boilers. Deposit probe measurements have been conducted in different biomass suspension-fired boilers by using advanced ash deposition probes. Two kinds of ash deposition probes have been used. A horizontal probe that has been developed further, which can register probe temperature, deposit mass uptake, heat uptake and video monitoring. First steps have also been taken for the development of a vertical probe that was employed for ash deposit formation measurements on a boiler furnace wall. In the first series of probe measurements, the influence of straw firing technology (grate and suspension) on ash transformation, deposit formation rate and deposit characteristics has been investigated. Full-scale probe measurements were conducted at a 250 MWth suspension boiler, firing straw and wood in suspension, and the results were compared with measurements conducted at a 105 MWth straw-fired grate boiler. Bulk elemental analysis of fly ashes revealed that fly ash from suspension firing of straw has high contents of Si, K and Ca, while fly ash from straw grate firing was rich in the volatile elements, K, Cl and S. SEM-EDS analysis showed that the fly ash from straw suspension firing consists of three kinds of particles: 1) flake type Si rich particles, 2) molten or partially molten particles (> 20 μm) rich in Si, K and Ca with small amounts of Mg, P, and potassium salts on the outer surface, and 3) small particles rich in K, Cl and S (aerosols, between 0.1 and 5 μm). Ash deposition data were compared with data from previously conducted deposit probe measurements in biomass-fired grate boilers. The comparison showed an increasing trend in deposit formation rate with increase in flue gas temperature. At a flue gas temperature of 650 ◦C, the deposit formation rate is typically from 5 to 30 g/m2/h and at 900 ◦C, the deposit formation rate is typically 20 to 110 g/m2/h. At higher fuel alkali vi ABSTRACT contents (K > 0.9 wt.%), the increase in deposit formation rate with flue gas temperature was more significant, compared to the increase in deposit formation rate at lower fuel alkali contents (K ≤ 0.9 wt.%). An increased flue gas temperature probably increases the fraction of molten ash as well as provides an increased content of gas phase alkali species, and both will lead to an increased deposit formation rate. The deposit formation rates during straw suspension firing and straw grate firing were on similar levels. This was observed even though the concentration of fly ash in the flue gas was higher during straw suspension firing. The objective of the second probe measuring series was to investigate the influence of fuel type (straw share in wood), probe exposure time, probe surface temperature (500 ◦C, 550 ◦C and 600 ◦C), and flue gas temperature (600–1050 ◦C) on the transient deposit build-up and shedding in a 350 MWth suspension boiler, firing straw and wood. Two different measures of deposit formation rate are used in the analysis of the data. The first is the integral deposit formation rate (IDF-rate) found by dividing the integral mass change over integral time intervals (of order several hours) by the time interval. The IDF-rate is then the result of both the deposit formation rate and shedding events in a given period. In this work IDF-rates were determined using 12 h intervals. The IDF-rate is similar to deposit formation rates determined from previous full-scale measuring data. A second measure, the derivative-based deposit formation rate (DDF-rate), was determined by calculating the local values of the time derivative of the deposit mass uptake, removing large negative values signifying major shedding events, and finally time smoothing the derivatives to remove excessive noise. The DDF-rate excludes the major shedding events. The overall DDF-rates were measured to be between 234 and 3105 g/m2/h. The IDF-rates were measured between 1 and 95 g/m2/h. The results showed that the DDF-rate was influenced by flue gas temperature and straw share, while changes in probe surface temperature had no significant influence. The IDF-rate, qualitatively related to the ratio between the time-integrated DDF-rate and the integration time, followed the same trends. Quantification of naturally occurring deposit shedding and deposit shedding during plant sootblowing was made via deposit mass uptake signals obtained from the deposit probe. The deposit shedding process was characterized by calculation of the amount of deposit removed at a shedding event [g/m2] and the frequency of the shedding events [h−1]. The results showed that the shedding process is stochastic and the amount of deposit removed varies even at constant local conditions. However, the deposit shedding rates showed an increasing trend with increase in flue gas temperatures and probe deposit mass loads. The deposit shedding rate was in most of the cases higher at a probe temperature of 500 ◦C than at a probe temperature of 600 ◦C. A possible reason for this is partial melting and/or sintering of the innermost deposit layer (rich in K, Cl and S) at higher probe viicontents (K > 0.9 wt.%), the increase in deposit formation rate with flue gas temperature was more significant, compared to the increase in deposit formation rate at lower fuel alkali contents (K ≤ 0.9 wt.%). An increased flue gas temperature probably increases the fraction of molten ash as well as provides an increased content of gas phase alkali species, and both will lead to an increased deposit formation rate. The deposit formation rates during straw suspension firing and straw grate firing were on similar levels. This was observed even though the concentration of fly ash in the flue gas was higher during straw suspension firing. The objective of the second probe measuring series was to investigate the influence of fuel type (straw share in wood), probe exposure time, probe surface temperature (500 ◦C, 550 ◦C and 600 ◦C), and flue gas temperature (600–1050 ◦C) on the transient deposit build-up and shedding in a 350 MWth suspension boiler, firing straw and wood. Two different measures of deposit formation rate are used in the analysis of the data. The first is the integral deposit formation rate (IDF-rate) found by dividing the integral mass change over integral time intervals (of order several hours) by the time interval. The IDF-rate is then the result of both the deposit formation rate and shedding events in a given period. In this work IDF-rates were determined using 12 h intervals. The IDF-rate is similar to deposit formation rates determined from previous full-scale measuring data. A second measure, the derivative-based deposit formation rate (DDF-rate), was determined by calculating the local values of the time derivative of the deposit mass uptake, removing large negative values signifying major shedding events, and finally time smoothing the derivatives to remove excessive noise. The DDF-rate excludes the major shedding events. The overall DDF-rates were measured to be between 234 and 3105 g/m2/h. The IDF-rates were measured between 1 and 95 g/m2/h. The results showed that the DDF-rate was influenced by flue gas temperature and straw share, while changes in probe surface temperature had no significant influence. The IDF-rate, qualitatively related to the ratio between the time-integrated DDF-rate and the integration time, followed the same trends. Quantification of naturally occurring deposit shedding and deposit shedding during plant sootblowing was made via deposit mass uptake signals obtained from the deposit probe. The deposit shedding process was characterized by calculation of the amount of deposit removed at a shedding event [g/m2] and the frequency of the shedding events [h−1]. The results showed that the shedding process is stochastic and the amount of deposit removed varies even at constant local conditions. However, the deposit shedding rates showed an increasing trend with increase in flue gas temperatures and probe deposit mass loads. The deposit shedding rate was in most of the cases higher at a probe temperature of 500 ◦C than at a probe temperature of 600 ◦C. A possible reason for this is partial melting and/or sintering of the innermost deposit layer (rich in K, Cl and S) at higher probe vii ABSTRACT surface temperature. This could cause the adhesion strength of the deposit to the probe to increase at the higher probe temperature. Quantification of the necessary Peak Impact Pressure (PIP) needed to remove the deposit was also made by use of a sootblowing probe in conjunction with the deposit probe. Results of deposit removal by artificial sootblowing showed that the deposits formed on a 500 ◦C probe temperature and at exposure time less than 91 h can be removed with a PIP of less than 55 kPa. However, an increase in probe exposure time and/or probe surface temperature (to 600 ◦C) significantly increases the PIP needed to remove the deposits. As a part of the third probe measurement series, full-scale probe measurements of deposit build-up and shedding were conducted at a 800 MWth suspension boiler, firing wood and natural gas, with the addition of coal fly ash. The results showed that the addition of coal fly ash can significantly affect the ash deposition behaviors and the deposit properties. At the location of the probe measurements with flue gas temperature of 1250– 1300 ◦C, although the addition of coal fly ash increases the

18 citations

Journal ArticleDOI
TL;DR: The use of waste wood as a fuel in power plants is becoming more widespread in Europe, because it is a renewable energy source with a lower cost than forest fuel as mentioned in this paper. But it is more corrosive than...
Abstract: The use of waste wood as a fuel in power plants is becoming more widespread in Europe, because it is a renewable energy source with a lower cost than forest fuel. However it is more corrosive than ...

18 citations

Journal ArticleDOI
TL;DR: In this article, a modified burst test was used in an extensive test program to characterize fuel cladding failure behavior under rapid loading conditions, and the results showed that cladding ductility is strongly temperature and loading rate dependent.

18 citations


Authors

Showing all 687 results

NameH-indexPapersCitations
Math Bollen5951917496
Björn Karlsson392304638
Johan Westin29785391
Lion Hirth29764941
Anders Wörman281093145
Ausilio Bauen28523664
Jesper Petersson24634359
Bernd Meyer242082059
Frank Rosillo-Calle23472112
Jan Blomgren221471591
Melanie Montgomery1866926
Falko Ueckerdt18402158
Shahriar Badiei1720626
Christian Bernstone1639992
Tomasz Kozlowski16126965
Network Information
Related Institutions (5)
National Renewable Energy Laboratory
14.8K papers, 663.2K citations

74% related

Polytechnic University of Milan
58.4K papers, 1.2M citations

74% related

Cranfield University
21.1K papers, 678.2K citations

74% related

Polytechnic University of Turin
41.3K papers, 789.3K citations

73% related

Delft University of Technology
94.4K papers, 2.7M citations

73% related

Performance
Metrics
No. of papers from the Institution in previous years
YearPapers
20231
20226
202137
202026
201919
201834