scispace - formally typeset
Search or ask a question

Showing papers in "European Radiology in 2008"


Journal ArticleDOI
TL;DR: This manuscript provides guidelines on the current best practice for the use of breast MRI, and the methods to be used, from the European Society of Breast Imaging (EUSOBI).
Abstract: The aim of breast MRI is to obtain a reliable evaluation of any lesion within the breast. It is currently always used as an adjunct to the standard diagnostic procedures of the breast, i.e., clinical examination, mammography and ultrasound. Whereas the sensitivity of breast MRI is usually very high, specificity—as in all breast imaging modalities—depends on many factors such as reader expertise, use of adequate techniques and composition of the patient cohorts. Since breast MRI will always yield MR-only visible questionable lesions that require an MR-guided intervention for clarification, MRI should only be offered by institutions that can also offer a MRI-guided breast biopsy or that are in close contact with a site that can perform this type of biopsy for them. Radiologists involved in breast imaging should ensure that they have a thorough knowledge of the MRI techniques that are necessary for breast imaging, that they know how to evaluate a breast MRI using the ACR BI-RADS MRI lexicon, and most important, when to perform breast MRI. This manuscript provides guidelines on the current best practice for the use of breast MRI, and the methods to be used, from the European Society of Breast Imaging (EUSOBI).

701 citations


Journal ArticleDOI
TL;DR: The recently introduced concept of “diffusion-weighted whole-body imaging with background body signal suppression” (DWIBS) now allows acquisition of volumetric diffusion- Weighted images of the entire body.
Abstract: Diffusion-weighted magnetic resonance imaging (DWI) provides functional information and can be used for the detection and characterization of pathologic processes, including malignant tumors. The recently introduced concept of “diffusion-weighted whole-body imaging with background body signal suppression” (DWIBS) now allows acquisition of volumetric diffusion-weighted images of the entire body. This new concept has unique features different from conventional DWI and may play an important role in whole-body oncological imaging. This review describes and illustrates the basics of DWI, the features of DWIBS, and its potential applications in oncology. Electronic supplementary material The online version of this article (doi:10.1007/s00330-008-0968-z) contains supplementary material, which is available to authorized users.

393 citations


Journal ArticleDOI
TL;DR: Measurements of the ADCs of focal liver lesions on the basis of a respiratory triggered DW-SS-EPI sequence may constitute a useful supplementary method for lesion characterization.
Abstract: The aim of this study was to determine apparent diffusion coefficients (ADCs) of focal liver lesions on the basis of a respiratory triggered diffusion-weighted single-shot echo-planar MR imaging sequence (DW-SS-EPI) and to evaluate whether ADC measurements can be used to characterize lesions. One hundred and two patients with focal liver lesions [11 hepatocellular carcinomas (HCC), 82 metastases, 4 focal nodular hyperplasias (FNH), 56 hemangiomas and 51 cysts; mean size, 16.6 mm; range 5–92 mm] were examined on a 1.5-T system using respiratory triggered DW-SS-EPI (b-values: 50, 300, 600 s/mm2). Results were correlated with histopathologic data and follow-up imaging. The ADCs of different lesion types were compared, and lesion discrimination using optimal thresholds for ADCs was evaluated. Mean ADCs (×10−3mm2/s) were 1.24 and 1.04 for normal and cirrhotic liver parenchyma and 1.05, 1.22, 1.40, 1.92 and 3.02 for HCCs, metastases, FNHs, hemangiomas and cysts, respectively. Mean ADCs differed significantly for all lesion types except for comparison of metastases with HCCs and FNHs. Overall, 88% of lesions were correctly classified as benign or malignant using a threshold value of 1.63 × 10−3mm2/s. Measurements of the ADCs of focal liver lesions on the basis of a respiratory triggered DW-SS-EPI sequence may constitute a useful supplementary method for lesion characterization.

391 citations


Journal ArticleDOI
TL;DR: RFA is a safe modality effective at reducing volume in benign thyroid nodules and several factors (patient age, volume and composition of the index nodule) were evaluated.
Abstract: This study evaluated the safety and volume reduction of ultrasonography (US)-guided radiofrequency ablation (RFA) for benign thyroid nodules, and the factors affecting the results obtained. A total of 302 benign thyroid nodules in 236 euthyroid patients underwent RFA between June 2002 and January 2005. RFA was carried out using an internally cooled electrode under local anesthesia. The volume-reduction ratio (VRR) was assessed by US and safety was determined by observing the complications during the follow-up period (1–41 months). The correlation between the VRR and several factors (patient age, volume and composition of the index nodule) was evaluated. The volume of index nodules was 0.11–95.61 ml (mean, 6.13 ± 9.59 ml). After ablation, the volume of index nodules decreased to 0.00–26.07 ml (mean, 1.12 ± 2.92 ml) and the VRR was 12.52–100% (mean, 84.11 ± 14.93%) at the last follow-up. A VRR greater than 50% was observed in 91.06% of nodules, and 27.81% of index nodules disappeared. The complications encountered were pain, hematoma and transient voice changes. In conclusion, RFA is a safe modality effective at reducing volume in benign thyroid nodules.

381 citations


Journal ArticleDOI
TL;DR: Gd-EOB-DTPA-enhanced MRI was superior in the diagnosis and therapeutic management of focal liver lesions compared with CT.
Abstract: A multicenter study has been employed to evaluate the diagnostic efficacy of magnetic resonance imaging (MRI) using the new liver-specific contrast agent gadoxetic acid (Gd-EOB-DTPA, Primovist), as opposed to contrast-enhanced biphasic spiral computed tomography (CT), in the diagnosis of focal liver lesions, compared with a standard of reference (SOR). One hundred and sixty-nine patients with hepatic lesions eligible for surgery underwent Gd-EOB-DTPA-enhanced MRI as well as CT within 6 weeks. Pathologic evaluation of the liver specimen combined with intraoperative ultrasound established the SOR. Data sets were evaluated on-site (14 investigators) and off-site (three independent blinded readers). Gd-EOB-DTPA was well tolerated. Three hundred and two lesions were detected in 131 patients valid for analysis by SOR. The frequency of correctly detected lesions was significantly higher on Gd-EOB-DTPA-enhanced MRI compared with CT in the clinical evaluation [10.44%; 95% confidence interval (CI): 4.88, 16.0]. In the blinded reading there was a trend towards Gd-EOB-DTPA-enhanced MRI, not reaching statistical significance (2.14%; 95% CI: -4.32, 8.6). However, the highest rate of correctly detected lesions with a diameter below 1 cm was achieved by Gd-EOB-DTPA-enhanced MRI. Differential diagnosis was superior for Gd-EOB-DTPA-enhanced MRI (82.1%) versus CT (71.0%). A change in surgical therapy was documented in 19 of 131 patients (14.5%) post Gd-EOB-DTPA-enhanced MRI. Gd-EOB-DTPA-enhanced MRI was superior in the diagnosis and therapeutic management of focal liver lesions compared with CT.

357 citations


Journal ArticleDOI
TL;DR: The results indicate that the cancer visibility on BT is superior to DM, which suggests that BT may have a higher sensitivity for breast cancer detection.
Abstract: The main purpose was to compare breast cancer visibility in one-view breast tomosynthesis (BT) to cancer visibility in one- or two-view digital mammography (DM). Thirty-six patients were selected on the basis of subtle signs of breast cancer on DM. One-view BT was performed with the same compression angle as the DM image in which the finding was least/not visible. On BT, 25 projections images were acquired over an angular range of 50 degrees, with double the dose of one-view DM. Two expert breast imagers classified one- and two-view DM, and BT findings for cancer visibility and BIRADS cancer probability in a non-blinded consensus study. Forty breast cancers were found in 37 breasts. The cancers were rated more visible on BT compared to one-view and two-view DM in 22 and 11 cases, respectively, (p < 0.01 for both comparisons). Comparing one-view DM to one-view BT, 21 patients were upgraded on BIRADS classification (p < 0.01). Comparing two-view DM to one-view BT, 12 patients were upgraded on BIRADS classification (p < 0.01). The results indicate that the cancer visibility on BT is superior to DM, which suggests that BT may have a higher sensitivity for breast cancer detection.

351 citations


Journal ArticleDOI
TL;DR: Clinical guidelines for multidetector computed tomography urography (CTU) by a group of experts from the European Society of Urogenital Radiology provide recommendations to optimize techniques and to unify the radiologist's approach to CTU.
Abstract: The aim was to develop clinical guidelines for multidetector computed tomography urography (CTU) by a group of experts from the European Society of Urogenital Radiology (ESUR). Peer-reviewed papers and reviews were systematically scrutinized. A summary document was produced and discussed at the ESUR 2006 and ECR 2007 meetings with the goal to reach consensus. True evidence-based guidelines could not be formulated, but expert guidelines on indications and CTU examination technique were produced. CTU is justified as a first-line test for patients with macroscopic haematuria, at high-risk for urothelial cancer. Otherwise, CTU may be used as a problem-solving examination. A differential approach using a one-, two- or three-phase protocol is proposed, whereby the clinical indication and the patient population will determine which CTU protocol is employed. Either a combined nephrographic-excretory phase following a split-bolus intravenous injection of contrast medium, or separate nephrographic and excretory phases following a single-bolus injection can be used. Lower dose (CTDIvol 5–6 mGy) is used for benign conditions and normal dose (CTDIvol 9–12 mGy) for potential malignant disease. A low-dose (CTDIvol 2–3 mGy) unenhanced series can be added on indication. The expert-based CTU guidelines provide recommendations to optimize techniques and to unify the radiologist’s approach to CTU.

300 citations


Journal ArticleDOI
TL;DR: Dual-source CTCA with 100 kV is feasible in patients of normal weight, results in a diagnostic image quality with a higher CNR, and at the same time significantly reduces the radiation dose.
Abstract: The purpose of this study was to investigate the effect of low kilovoltage dual-source computed tomography coronary angiography (CTCA) on qualitative and quantitative image quality parameters and radiation dose. Dual-source CTCA with retrospective ECG gating was performed in 80 consecutive patients of normal weight. Forty were examined with a standard protocol (120 kV/330mAs), 20 were examined at 100 kV/330mAs, and 20 at 100 kV/220mAs. Two blinded observers independently assessed image quality of each coronary segment and measured the image parameters noise, attenuation, and contrast-to-noise ratio (CNR). The effective radiation dose was calculated using CT dose volume index and the dose-length product. Diagnostic image quality was obtained in 99% of all coronary segments (1,127/1,140) without significant differences among the protocols. Image noise, attenuation, and CNR were significantly higher for 100 kV/330mAs (26 ± 3 HU, 549 ± 62 HU, 25.5 ± 3.2; each P < 0.01) and 100 kV/220mAs (27 ± 2 HU, 560 ± 43 HU, 25.0 ± 2.2; each P < 0.01) when compared to the 120-kV protocol (21 ± 2 HU, 317 ± 28 HU, 20.6 ± 1.7). There was no significant difference between the two 100-kV protocols. Estimated effective radiation dose of the 120-kV protocol (8.9 ± 1.2 mSv) was significantly higher than the 100 kV/330mAs (6.7 ± 0.8 mSv, P < 0.01) or 100 kV/220mAs (4.4 ± 0.6 mSv, P < 0.001) protocols. Dual-source CTCA with 100 kV is feasible in patients of normal weight, results in a diagnostic image quality with a higher CNR, and at the same time significantly reduces the radiation dose.

299 citations


Journal ArticleDOI
TL;DR: In addition to morphological features on nonenhanced and postcontrast MR sequences, DW imaging and ADC measurement may have a potential ability to differentiate uterine sarcomas from benign leiomyomas.
Abstract: The usefulness of diffusion-weighted (DW) magnetic resonance (MR) imaging for the diagnosis of uterine sarcomas was investigated, as well as whether DW images and quantitative measurement of apparent diffusion coefficient (ADC) values can facilitate differentiating uterine sarcomas from benign leiomyomas. MR images including DW images were obtained in 43 surgically treated patients with 58 myometrial tumors, including seven uterine sarcomas (five leiomyosarcomas and two endometrial stromal sarcomas) and 51 benign leiomyomas (43 ordinary leiomyomas, two cellular leiomyomas and six degenerated leiomyomas). Qualitative analysis of non-enhanced and postcontrast MR images and DW images and quantitative measurement of ADC values were performed for each myometrial tumor. Both uterine sarcomas and cellular leiomyomas exhibited high signal intensity on DW images, whereas ordinary leiomyomas and most degenerated leiomyomas showed low signal intensity. The mean ADC value (10−3 mm2/s) of sarcomas was 1.17 ± 0.15, which was lower than those of the normal myometrium (1.62 ± 0.11) and degenerated leiomyomas (1.70 ± 0.11) without any overlap; however, they were overlapped with those of ordinary leiomyomas and cellular leiomyomas. In addition to morphological features on nonenhanced and postcontrast MR sequences, DW imaging and ADC measurement may have a potential ability to differentiate uterine sarcomas from benign leiomyomas.

269 citations


Journal ArticleDOI
TL;DR: This project relies on three pillars: three-dimensional (3D) surface scanning for the documentation of body surfaces, and both multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) to visualise the internal body.
Abstract: The transdisciplinary research project Virtopsy is dedicated to implementing modern imaging techniques into forensic medicine and pathology in order to augment current examination techniques or even to offer alternative methods. Our project relies on three pillars: three-dimensional (3D) surface scanning for the documentation of body surfaces, and both multislice computed tomography (MSCT) and magnetic resonance imaging (MRI) to visualise the internal body. Three-dimensional surface scanning has delivered remarkable results in the past in the 3D documentation of patterned injuries and of objects of forensic interest as well as whole crime scenes. Imaging of the interior of corpses is performed using MSCT and/or MRI. MRI, in addition, is also well suited to the examination of surviving victims of assault, especially choking, and helps visualise internal injuries not seen at external examination of the victim. Apart from the accuracy and three-dimensionality that conventional documentations lack, these techniques allow for the re-examination of the corpse and the crime scene even decades later, after burial of the corpse and liberation of the crime scene. We believe that this virtual, non-invasive or minimally invasive approach will improve forensic medicine in the near future.

262 citations


Journal ArticleDOI
TL;DR: The currently best available evidence shows no statistically significant difference in accuracy of US and CT in diagnosing acute colonic diverticulitis (ACD), and both US andCT can be used as initial diagnostic tool until new evidence is brought forward.
Abstract: The purpose was to investigate the diagnostic accuracy of graded compression ultrasonography (US) and computed tomography (CT) in diagnosing acute colonic diverticulitis (ACD) in suspected patients We performed a systematic review and meta-analysis of the accuracy of CT and US in diagnosing ACD Study quality was assessed with the QUADAS tool Summary estimates of sensitivity and specificity were calculated using a bivariate random effects model Six US studies evaluated 630 patients, and eight CT studies evaluated 684 patients Overall, their quality was moderate We did not identify meaningful sources of heterogeneity in the study results Summary sensitivity estimates were 92% (95% CI: 80%-97%) for US versus 94% (95%CI: 87%-97%) for CT (p = 065) Summary specificity estimates were 90% (95%CI: 82%-95%) for US versus 99% (95%CI: 90%-100%) for CT (p = 007) For the identification of alternative diseases sensitivity ranged between 33% and 78% for US and between 50% and 100% for CT The currently best available evidence shows no statistically significant difference in accuracy of US and CT in diagnosing ACD Therefore, both US and CT can be used as initial diagnostic tool until new evidence is brought forward However, CT is more likely to identify alternative diseases

Journal ArticleDOI
TL;DR: The initial experience may warrant further exploration of DECT as a possibly feasible single imaging investigation for the comprehensive diagnosis of coronary stenosis and myocardial ischemia.
Abstract: We aimed to evaluate the feasibility of diagnosing coronary stenosis and myocardial ischemia with a single dual-energy CT (DECT) acquisition. Thirty-five patients underwent contrast-enhanced, ECG-gated DECT of the heart while independently operating the two tubes of a dual-source CT system at high- and low-energy X-ray spectra. From the same raw data, coronary CTA (cCTA) studies were reconstructed for stenosis detection, and the myocardial blood-pool was analyzed by determining the tissue iodine content. Two independent observers analyzed all studies for stenosis and myocardial blood-pool deficits. Results were correlated with SPECT, coronary catheterization and cCTA on a segmental basis. cCTA had 98% sensitivity, 88% specificity and 92% accuracy for detection of >50% stenosis. DECT detected myocardial ischemia with 84% sensitivity, 94% specificity and 92% accuracy. Our initial experience may warrant further exploration of DECT as a possibly feasible single imaging investigation for the comprehensive diagnosis of coronary stenosis and myocardial ischemia.

Journal ArticleDOI
TL;DR: Investigation of apparent diffusion coefficient measurement with MRI in the assessment of cervix cancer found it may have predictive value in squamous tumors, but further long-term study will determine the ultimate clinical utility.
Abstract: The purpose was to investigate the potential value of apparent diffusion coefficient (ADC) measurement with MRI in the assessment of cervix cancer. Diffusion-weighted MRI was performed in 47 patients with cervical carcinoma undergoing chemoradiation therapy and 26 normal controls on a 1.5-T system with a b-value of 600 s/mm2. FIGO stage, tumor volume, nodal status, interstitial fluid pressure (IFP) and oxygen measurements were recorded. Response was defined as no visible tumor 3–6 months following completion of therapy. The average median ADC (mADC) of cervical carcinomas (1.09±0.20×10−3 mm2/s) was significantly lower than normal cervix (2.09±0.46×10−3 mm2/s) (P<0.001). There was no correlation between mADC, nodal status, tumor volume, IFP or oxygen measurements. mADC was significantly lower in FIGO stages T1b/T2a (0.986 × 10−3 mm2/s) compared to T2b (1.21×10−3 mm2/s) and T3/T4 (1.10×10−3 mm2/s) (P<0.001). In patients with squamous carcinomas the 90th percentile of ADC values was lower in responders than non-responders (P<0.05). Median ADC in cervix carcinoma is significantly lower compared to normal cervix. ADC may have predictive value in squamous tumors, but further long-term study will determine the ultimate clinical utility.

Journal ArticleDOI
TL;DR: Apparent diffusion coefficient measurements can be useful in differentiating malignant from benign focal liver lesions and Respiratory gated diffusion-weighted imaging in the liver is technically feasible.
Abstract: The purpose of this study was to measure apparent diffusion coefficient values of normal liver parenchyma and focal liver lesions utilizing a respiratory gated diffusion sequence with multiple b-values and to investigate whether apparent diffusion coefficient (ADC) measurements may be utilized to characterize and differentiate between malignant and benign focal hepatic lesions. Thirty-eight consecutive patients underwent MRI of the liver including diffusion-weighted imaging (DWI). A single-shot echo planar imaging sequence was applied in coronal orientation with multiple b-values (0, 50, 500, 1,000 s/mm2) and respiratory gating. ADC values were recorded on corresponding maps utilizing region of interest measurements in patients with benign (group A), malignant (group B) focal lesions and liver parenchyma (group C). Statistical analysis was applied to check whether differences in mean ADC values were significant (p<0.05). No focal lesions were detected in 11 patients, with a mean ADC value (CI 95%) of liver parenchyma 1.25×10−3 mm2/s (1.21×10−3 mm2/s−1.29×10−3 mm2/s). Differences in mean ADC of liver parenchyma between group A and B were not significant (p=0.054, 1.30×10−3 mm2/s and 1.31×10−3 mm2/s, respectively). Mean ADC value (95% CI) of 22 benign lesions found in 18 patients was 2.55×10−3 mm2/s (2.35×10−3 mm2/s−2.74×10−3 mm2/s), while the mean ADC value (95% CI) of 16 malignant lesions recorded in 9 patients was 1.04×10−3 mm2/s (0.9×10−3 mm2/s−1.17×10−3 mm2/s). The difference between mean ADC values of benign and malignant focal lesions was statistically significant (p<0.0001). Respiratory gated diffusion-weighted imaging in the liver is technically feasible. Apparent diffusion coefficient measurements can be useful in differentiating malignant from benign focal liver lesions.

Journal ArticleDOI
TL;DR: Radiation exposure of dual-source CT coronary angiography using an ECG-pulsing protocol reducing the tube current to 20% significantly decreases with increasing heart rates, despite using wider pulsing windows at higher heart rates.
Abstract: The purpose of this study was to quantify radiation dose parameters of dual-source CT coronary angiography. Eighty patients underwent contrast-enhanced, retrospectively ECG-gated dual-source CT coronary angiography with heart rate-adapted ECG pulsing using two algorithms: In 40 patients, the tube current was reduced to 20% (Amin1) of the normal tube current (Amax) outside the pulsing window; in 40 patients tube current was reduced to 4% (Amin2) of Amax. Mean CTDIvol in the Amin1 group was 45.1 ± 3.6 mGy; the mean CTDIvol in the Amin2 group was 39.1 ± 3.2 mGy, with CTDIvol in the Amin2 group being significantly reduced when compared to the Amin1 group (P < 0.001). A significant negative correlation was found between CTDIvol and heart rate in group Amin1 (r = −0.82, P < 0.001), whereas no correlation was found between CTDIvol and heart rate in group Amin2 (r = −0.066). Using the conversion coefficient for the chest, dual-source CT coronary angiography resulted in an estimated mean effective dose of 8.8 mSv in the Amin1 group and 7.8 mSv in the Amin2. Radiation exposure of dual-source CT coronary angiography using an ECG-pulsing protocol reducing the tube current to 20% significantly decreases with increasing heart rates, despite using wider pulsing windows at higher heart rates. When using a protocol with reduced tube current of 4%, the radiation dose is significantly lower, irrespective of the heart rate.

Journal ArticleDOI
TL;DR: Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage as well as pneumothorax and CT-guided biopsy of smaller lesions correlates with a higher bleeding rate.
Abstract: The influence of various variables on the rate of pneumothorax and intrapulmonal hemorrhage associated with computed tomography (CT)-guided transthoracic needle biopsy of the lung were evaluated retrospectivly. One hundred and thirty-three patients underwent CT guided biopsy of a pulmonary lesion. Two patients were biopsied twice. Variables analyzed were lesion size, lesion location, number of pleural needle passes, lesion margin, length of intrapulmonal biopsy path and puncture time. Eighteen-gauge (18G) cutting needles (Trucut, Somatex, Teltow, Germany) were used for biopsy. Pneumothorax occured in 23 of 135 biopsies (17%). Chest tube placement was required in three out of 23 cases of pneumothorax (2% of all biopsies). Pneumothorax rate was significantly higher when the lesions were located in the lung parenchyma compared with locations at the pleura or chest wall (P < 0.05), but all pneumothorax cases which required chest tube treatment occured in lesions located less than 2 cm from the pleura. Longer puncture time led to an increase in pneumothorax rate (P < 0.05). Thirty-seven (27%) out of 135 biopsies showed perifocal hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage and pneumothorax (P < 0.05). Significantly more hemorrhage occured when the pleura was penetrated twice during the puncture (P < 0.05). Lesion size <4 cm is strongly correlated with higher occurence of perifocal hemorrhage (P < 0.05). Lesion margination showed no significant effect on complication rate. CT-guided biopsy of smaller lesions correlates with a higher bleeding rate. Puncture time should be minimized to reduce pneumothorax rate. Passing the pleura twice significantly increases the risk of hemorrhage. Intrapulmonal biopsy paths longer than 4 cm showed significantly higher numbers of perifocal hemorrhage as well as pneumothorax.

Journal ArticleDOI
TL;DR: Three-dimensional dose distributions can be accurately calculated with the MC tool for arbitrary scanners and protocols including tube current modulation schemes, and the tool has been extended to further scanners and to flat-detector CT.
Abstract: Estimating the dose delivered to the patient in X-ray computed tomography (CT) examinations is not a trivial task. Monte Carlo (MC) methods appear to be the method of choice to assess the 3D dose distribution. The purpose of this work was to extend an existing MC-based tool to account for arbitrary scanners and scan protocols such as multi-slice CT (MSCT) scanners and to validate the tool in homogeneous and heterogeneous phantoms. The tool was validated by measurements on MSCT scanners for different scan protocols under known conditions. Quantitative CT Dose Index (CTDI) measurements were performed in cylindrical CTDI phantoms and in anthropomorphic thorax phantoms of various sizes; dose profiles were measured with thermoluminescent dosimeters (TLD) in the CTDI phantoms and compared with the computed dose profiles. The in-plane dose distributions were simulated and compared with TLD measurements in an Alderson-Rando phantom. The calculated dose values were generally within 10% of measurements for all phantoms and all investigated conditions. Three-dimensional dose distributions can be accurately calculated with the MC tool for arbitrary scanners and protocols including tube current modulation schemes. The use of the tool has meanwhile also been extended to further scanners and to flat-detector CT.

Journal ArticleDOI
TL;DR: MRE can serve as the diagnostic procedure for initially evaluating patients suspected of having Crohn’s disease and MR per OS may have a role in patients that refuse or have failed intubation and also for follow-up.
Abstract: To prospectively compare the diagnostic accuracy of MR enteroclysis with duodenal intubation with MRI after drinking oral contrast agent only (MR enterography) with conventional enteroclysis (conv-E) as reference standard in patients with Crohn’s disease. Forty consecutive patients (22 males and 18 females; mean age 36; range 16–74 years) with proven Crohn’s disease underwent conv-E and MR imaging. Twenty-two patients underwent MR enteroclysis with intubation (MRE) and 18 underwent MR-enterography (MR per OS). Two radiologists reached a consensus about the following imaging findings: luminal distension and visualization of superficial mucosal, mural and mesenteric abnormalities. Standard descriptive statistics and a Wilcoxon rank sum test were used. Statistical significance was inferred at P < 0.05. There was no significant difference in the adequacy of luminal distention between the MRE and conv-E (P = 0.08), and both were statistically superior in comparison to MR per OS in the distension of the jejunum (P < 0.01) and less significant at the ileum and terminal ileum levels (P < 0.05). MRE and conv-E were comparable for the accuracy of superficial mucosal abnormalities; meanwhile conv-E compared with MR per OS was statistically superior (P < 0.01). MRE compared with MR per OS was statistically better when visualizing superficial abnormalities (P < 0.01). No statistically significant differences were found in assessing the diagnostic efficacy between MR examinations for the depiction of mural stenosis (P = 0.105) and fistulae (P = 0.67). The number of detected mesenteric findings was significantly higher with both MRE and MR per OS compared to conv-E (P < 0.01). MRE can serve as the diagnostic procedure for initially evaluating patients suspected of having Crohn’s disease. MR per OS may have a role in patients that refuse or have failed intubation and also for follow-up.

Journal ArticleDOI
TL;DR: DW imaging depicted the tumors in 14 of 15 patients with peritoneal dissemination as abnormal signal intensity, and plays an important role in the diagnosis and therapeutic management of patients with gynecological malignancy.
Abstract: The aim of this study is to evaluate the usefulness of diffusion-weighted (DW) magnetic resonance (MR) imaging in detecting peritoneal dissemination in cases of gynecological malignancy. We retrospectively analyzed MR images obtained from 26 consecutive patients with gynecological malignancy. Peritoneal dissemination was histologically diagnosed in 15 of the 26 patients after surgery. We obtained DW images and half-Fourier single-shot turbo-spin-echo images in the abdomen and pelvis, and then generated fusion images. Coronal maximum-intensity-projection images were reconstructed from the axial source images. Reader interpretations were compared with the laparotomy findings in the surgical records. Receiver-operating characteristic (ROC) curves were used to represent the presence of peritoneal dissemination. In addition, the sensitivity and specificity were calculated. DW imaging depicted the tumors in 14 of 15 patients with peritoneal dissemination as abnormal signal intensity. ROC analysis yielded Az values of 0.974 and 0.932 for the two reviewers. The mean sensitivity and specificity were 90 and 95.5%. DW imaging plays an important role in the diagnosis and therapeutic management of patients with gynecological malignancy.

Journal ArticleDOI
TL;DR: The utility of measuring the corpus callosal angle for the diagnosis of idiopathic normal pressure hydrocephalus (INPH) was investigated and an accuracy of 93%, sensitivity of 97%, and specificity of 88% were observed for discrimination of INPH from AD patients.
Abstract: The utility of measuring the corpus callosal angle (CA) for the diagnosis of idiopathic normal pressure hydrocephalus (INPH) was investigated. Three-dimensional magnetic resonance imaging (MRI) was performed in 34 INPH patients, 34 Alzheimer’s disease (AD) patients, and 34 normal control (NC) subjects. Measurement of the CA on the coronal MR images of the posterior commissure perpendicular to the anteroposterior commissure plane was performed for all subjects. The CA of the INPH group (mean ± SD, 66 ± 14°) was significantly smaller than those of the AD (104 ± 15°) and NC (112 ± 11°) groups. When using the threshold of the mean − 2SD value of the NC group (= 90°), an accuracy of 93%, sensitivity of 97%, and specificity of 88% were observed for discrimination of INPH from AD patients. Measuring the CA helps in differentiating INPH patients from AD and normally aged subjects.

Journal ArticleDOI
TL;DR: The data in this investigation strongly suggest that the stability of the Gd-complex is a key factor for the development of NSF-like symptoms in this experimental setting.
Abstract: Recent reports suggest that nephrogenic systemic fibrosis (NSF) is associated with the administration of gadolinium (Gd)-based contrast agents (GBCAs) and in particular with the stability of the Gd-complex. The aim of this investigation was to compare GBCAs and their potential to trigger NSF. Forty-two healthy male rats received repeated intravenous injections of six different GBCAs at high doses to simulate the exposure seen in patients with severe renal dysfunction. Histopathological and immunohistochemical analysis of the skin was performed, and the concentrations of Gd, zinc and copper were measured in several tissues by inductive coupled plasma atomic emission spectroscopy. Macroscopic and histological skin changes similar to those seen in NSF patients were only observed in rats receiving Omniscan. In addition, very high concentrations of Gd were observed in the animals treated with Omniscan, and, to a lesser extent, in animals treated with OptiMARK. Significantly lower levels of Gd were found after the treatment with ionic linear agents and even less after the treatment with macrocyclic agents. The data in this investigation strongly suggest that the stability of the Gd-complex is a key factor for the development of NSF-like symptoms in this experimental setting.

Journal ArticleDOI
TL;DR: This study was an initial phase II trial in humans of molecular magnetic resonance (MR) imaging for improved visualization of thrombi in vessel territories potentially responsible for stroke using a new fibrin-specific contrast agent (EP-2104R).
Abstract: This study was an initial phase II trial in humans of molecular magnetic resonance (MR) imaging for improved visualization of thrombi in vessel territories potentially responsible for stroke using a new fibrin-specific contrast agent (EP-2104R). Eleven patients with thrombus in the left ventricle (n = 2), left or right atrium (n = 4), thoracic aorta (n = 4) or carotid artery (n = 1) as verified by an index examination (ultrasound, computed tomograpy, or conventional MR) were enrolled. All MR imaging was performed on 1.5 T whole-body MR-system using an inversion-recovery black-blood gradient-echo sequence. The same sequence was performed before and 2–6 h after low-dose intravenous administration of 4 μmol/kg EP-2104R. Two investigators assessed image quality and signal amplification. Furthermore, contrast-to-noise ratios (CNR) between the clot and the blood pool/surrounding soft tissue before and after administration of the contrast agent were compared using Student’s t-test. MR imaging and data analysis were successfully completed in 10 patients. No major adverse effects occurred. On enhanced images, thrombi demonstrated high signal amplification, typically at the clot surface, with a significantly increased contrast in comparison to the surrounding blood pool and soft tissue (CNR for clot vs. blood pool, unenhanced and enhanced: 6 ± 8 and 29 ± 14; CNR for clot vs. soft tissue, unenhanced and enhanced: 0 ± 4 and 21 ± 13; P < 0.01 for both comparisons). EP-2104R allows for molecular MR imaging of thrombi potentially responsible for stroke. High contrast between thrombus and surrounding blood and soft tissues can be achieved with enhanced imaging.

Journal ArticleDOI
TL;DR: The purpose is to evaluate the diagnostic accuracy of apparent diffusion coefficient (ADC) measurement in differentiating malignant from benign uterine endometrial cavity lesions in 25 female patients and to compare ADC values between malignant and benign lesions using Student’s t-test.
Abstract: Our purpose is to evaluate the diagnostic accuracy of apparent diffusion coefficient (ADC) measurement in differentiating malignant from benign uterine endometrial cavity lesions. We retrospectively evaluated 25 uterine endometrial cavity lesions in 25 female patients: endometrial carcinoma (n = 11), carcinosarcoma (n = 2), submucosal leiomyoma (n = 8), and endometrial polyp (n = 4). Diffusion-weighted images were performed at 1.5 T with b factors of 0-1,000/mm(2). The region of interest was defined within the tumor on T2-weighted EPI image and then manually copied to an ADC map. Thereby, the ADC value was obtained. We compared ADC values between malignant and benign lesions using Student's t-test. The mean and standard deviation of ADC values (x10(-3) mm(2)/s) were as follows: endometrial carcinoma, 0.98+/-0.21; carcinosarcoma, 0.97+/-0.02; submucosal leiomyoma, 1.37+/-0.28; and endometrial polyp, 1.58+/-0.45. The ADC values differed significantly between malignant (0.98+/-0.19) and benign lesions (1.44+/-0.34) (P < 0.01). We defined malignant tumors as cases with an ADC value less than 1.15 x 10(-3) mm(2)/s for obtaining the highest accuracy. Sensitivity, specificity, and accuracy were 84.6%, 100%, and 92%, respectively. ADC measurement can provide useful information in differentiating malignant from benign uterine endometrial cavity lesions.

Journal ArticleDOI
TL;DR: Metal self-expandable stents have proved superior to plastic stents and should therefore be used in PTBD for palliation of malignant obstructive jaundice.
Abstract: Percutaneous biliary drainage and stenting (PTBD) for palliation of malignant obstructive jaundice has evolved to a safe and effective technique. PTBD is equally effective for treatment of distal and proximal bile obstruction. Metal self-expandable stents have proved superior to plastic stents and should therefore be used. Technical success is >90% en clinical success is >75% in all major series. There are a considerable number of complications, but most can be treated conservatively and procedure-related mortality is 10% in many series, but this is largely due to the underlying disease. About 10–30% of patients will have recurrent jaundice at some point in their disease after PTBD and require re-intervention.

Journal ArticleDOI
TL;DR: Different fluorochromes for cell labeling, labeling methods and OI-based cell-tracking techniques will be reviewed with respect to their technical principles, current applications and aims for clinical translation.
Abstract: Adaptability, sensitivity, resolution and non-invasiveness are the attributes that have contributed to the longstanding use of light as an investigational tool and form the basis of optical imaging (OI). OI, which encompasses numerous techniques and methods, is rapid (<5 min), inexpensive, noninvasive, nontoxic (no radiation) and has molecular (single-cell) sensitivity, which is equal to that of conventional nuclear imaging and several orders of magnitude greater than MRI. This article provides a comprehensive overview of emerging applications of OI-based techniques for in vivo monitoring of new stem cell-based therapies. Different fluorochromes for cell labeling, labeling methods and OI-based cell-tracking techniques will be reviewed with respect to their technical principles, current applications and aims for clinical translation. Advantages and limitations of these new OI-based cell-tracking techniques will be discussed. Non-invasive mapping of cells labeled with fluorochromes or OI marker genes has the potential to evolve further within the clinical realm.

Journal ArticleDOI
TL;DR: In conclusion, 64-slice CT-CA provides optimal visualization of the variable and complex anatomy of coronary arteries because of the improved isotropic spatial resolution and flexible post-processing tool.
Abstract: The aim of our study was to assess the prevalence of variants and anomalies of the coronary artery tree in patients who underwent 64-slice computed tomography coronary angiography (CT-CA) for suspected or known coronary artery disease. A total of 543 patients (389 male, mean age 60.5 ± 10.9) were reviewed for coronary artery variants and anomalies including post-processing tools. The majority of segments were identified according to the American Heart Association scheme. The coronary dominance pattern results were: right, 86.6%; left, 9.2%; balanced, 4.2%. The left main coronary artery had a mean length of 112 ± 55 mm. The intermediate branch was present in the 21.9%. A variable number of diagonals (one, 25%; two, 49.7%; more than two, 24%; none, 1.3%) and marginals (one, 35.2%; two, 46.2%; more than two, 18%; none, 0.6%) was visualized. Furthermore, CT-CA may visualize smaller branches such as the conus branch artery (98%), the sinus node artery (91.6%), and the septal branches (93%). Single or associated coronary anomalies occurred in 18.4% of the patients, with the following distribution: 43 anomalies of origin and course, 68 intrinsic anomalies (59 myocardial bridging, nine aneurisms), three fistulas. In conclusion, 64-slice CT-CA provides optimal visualization of the variable and complex anatomy of coronary arteries because of the improved isotropic spatial resolution and flexible post-processing tool.

Journal ArticleDOI
TL;DR: In this article, the diagnostic reference levels (DRLRLs) for various age groups were established in terms of CTDIvol: 20, 30, 40, 60 mGy, 5, 8, 10, 12 mGy; 7, 9, 13, 16 mGy.
Abstract: This work aimed at assessing the doses delivered in Switzerland to paediatric patients during computed tomography (CT) examinations of the brain, chest and abdomen, and at establishing diagnostic reference levels (DRLs) for various age groups. Forms were sent to the ten centres performing CT on children, addressing the demographics, the indication and the scanning parameters: number of series, kilovoltage, tube current, rotation time, reconstruction slice thickness and pitch, volume CT dose index (CTDIvol) and dose length product (DLP). Per age group, the proposed DRLs for brain, chest and abdomen are, respectively, in terms of CTDIvol: 20, 30, 40, 60 mGy; 5, 8, 10, 12 mGy; 7, 9, 13, 16 mGy; and in terms of DLP: 270, 420, 560, 1,000 mGy cm; 110, 200, 220, 460 mGy cm; 130, 300, 380, 500 mGy cm. An optimisation process should be initiated to reduce the spread in dose recorded in this study. A major element of this process should be the use of DRLs.

Journal ArticleDOI
TL;DR: A new method and corresponding algorithm for fast segmentation of the liver and its internal lesions from CT scans that allowed robust and efficient liver and lesion segmentations very close to the ground truth, in a relatively short processing time.
Abstract: Accurate knowledge of the liver structure, including liver surface and lesion localization, is usually required in treatments such as liver tumor ablations and/or radiotherapy. This paper presents a new method and corresponding algorithm for fast segmentation of the liver and its internal lesions from CT scans. No interaction between the user and analysis system is required for initialization since the algorithm is fully automatic. A statistical model-based approach was created to distinguish hepatic tissue from other abdominal organs. It was combined to an active contour technique using gradient vector flow in order to obtain a smoother and more natural liver surface segmentation. Thereafter, automatic classification was performed to isolate hepatic lesions from liver parenchyma. Twenty-one datasets, presenting different anatomical and pathological situations, have been processed and analyzed. Special focus has been driven to the resulting processing time together with quality assessment. Our method allowed robust and efficient liver and lesion segmentations very close to the ground truth, in a relatively short processing time (average of 11.4 s for a 512 × 512-pixel slice). A volume overlap of 94.2% and an accuracy of 3.7 mm were achieved for liver surface segmentation. Sensitivity and specificity for tumor lesion detection were 82.6% and 87.5%, respectively.

Journal ArticleDOI
Chadi Khalil, C. Hancart, V. Le Thuc, C. Chantelot, D. Chechin1, A. Cotten 
TL;DR: The purpose was to demonstrate the feasibility of in vivo diffusion tensor imaging and tractography of the human median nerve with a 1.5-T MR scanner and to assess potential differences in diffusion between healthy volunteers and patients suffering from carpal tunnel syndrome.
Abstract: The purpose was to demonstrate the feasibility of in vivo diffusion tensor imaging (DTI) and tractography of the human median nerve with a 1.5-T MR scanner and to assess potential differences in diffusion between healthy volunteers and patients suffering from carpal tunnel syndrome. The median nerve was examined in 13 patients and 13 healthy volunteers with MR DTI and tractography using a 1.5-T MRI scanner with a dedicated wrist coil. T1-weighted images were performed for anatomical correlation. Mean fractional anisotropy (FA) and mean apparent diffusion coefficient (ADC) values were quantified in the median nerve on tractography images. In all subjects, the nerve orientation and course could be detected with tractography. Mean FA values were significantly lower in patients (p=0.03). However, no statistically significant differences were found for mean ADC values. In vivo assessment of the median nerve in the carpal tunnel using DTI with tractography on a 1.5-T MRI scanner is possible. Microstructural parameters can be easily obtained from tractography images. A significant decrease of mean FA values was found in patients suffering from chronic compression of the median nerve. Further investigations are necessary to determine if mean FA values may be correlated with the severity of nerve entrapment.

Journal ArticleDOI
TL;DR: This review summarizes the most recent technical developments with regard to new detector techniques, options for dose reduction and optimized image processing, and explains the meaning of the exposure indicator or the dose reference level as tools for the radiologist to control the dose.
Abstract: The introduction of digital radiography not only has revolutionized communication between radiologists and clinicians, but also has improved image quality and allowed for further reduction of patient exposure. However, digital radiography also poses risks, such as unnoticed increases in patient dose and suboptimum image processing that may lead to suppression of diagnostic information. Advanced processing techniques, such as temporal subtraction, dual-energy subtraction and computer-aided detection (CAD) will play an increasing role in the future and are all targeted to decrease the influence of distracting anatomic background structures and to ease the detection of focal and subtle lesions. This review summarizes the most recent technical developments with regard to new detector techniques, options for dose reduction and optimized image processing. It explains the meaning of the exposure indicator or the dose reference level as tools for the radiologist to control the dose. It also provides an overview over the multitude of studies conducted in recent years to evaluate the options of these new developments to realize the principle of ALARA. The focus of the review is hereby on adult applications, the relationship between dose and image quality and the differences between the various detector systems.