scispace - formally typeset
Journal ArticleDOI

A 1-D analysis of ejector performance

TLDR
In this paper, a 1D analysis for the prediction of ejector performance at critical-mode operation is carried out, where constant pressure mixing is assumed to occur inside the constant-area section of the ejector and the entrained flow at choking condition is analyzed.
Abstract
A 1-D analysis for the prediction of ejector performance at critical-mode operation is carried out in the present study. Constant-pressure mixing is assumed to occur inside the constant-area section of the ejector and the entrained flow at choking condition is analyzed. We also carried out an experiment using 11 ejectors and R141b as the working fluid to verify the analytical results. The test results are used to determine the coefficients, h p, h s, f p and f m defined in the 1-D model by matching the test data with the analytical results. It is shown that the1-D analysis using the empirical coefficients can accurately predict the performance of the ejectors. q 1999 Elsevier Science Ltd and IIR. All rights reserved.

read more

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI

Studies on Shock Wave Structures in Supersonic Ejector and its Influence on Ejector Performance

TL;DR: In this article , the first shock wave structures in a supersonic ejector were analyzed with experimental and numerical methods, and the relationship between the performance of the ejector and the shock structures was established, the entrainment ratio is positively correlated with the first wave aspect ratio and has a good linear relationship.

Performance of R141b Ejector with Thermal Storage for Solar Air Conditioning

TL;DR: In this article, the performance analysis of the R141b ejector includes analysis in economics, and the first step is to determine the operating condition and ejector geometry through computer calculation program, the second step ejector is fabricated and equipped to solar ejector refrigeration system, it is found that, average COP is 0265 and average COP 0265, respectively.
Journal ArticleDOI

Exergy Analysis of an Ejector Cooling System by Modified Gouy–Stodola Equation

TL;DR: In this paper, exergy destruction analysis of a heat-assisted ejector cooling system has been carried out using a modified Gouy-Stodola equation, which provides a more accurate analysis of the exergy degradation.
Journal ArticleDOI

Comparative designs and optimizations of the steam ejector for a CHP system

TL;DR: In this paper , the authors proposed a novel CHP cascade heating system integrated with a steam ejector and carried out research about ejector comparative designs and optimizations, and the software Fluent was used for numerical simulation to analyze and compare the internal flow characteristics of the ejector.
Proceedings ArticleDOI

Exergy Analysis of the Combined Ejector - Vapor Compression Refrigeration System Using R134a as Working Fluid

TL;DR: In this article, the authors presented a comprehensive investigation of a combined ejector-vapor compression refrigeration system using exergy analysis and found that ejector is the most irreversible part in the system (34.36%).
References
More filters
Journal ArticleDOI

A theoretical and experimental study of a small-scale steam jet refrigerator

TL;DR: In this paper, a small-capacity steam jet refrigerator has been tested with boiler temperatures in the range 120-140°C and the experimental data were found to be within 85% of the theoretical values.
Journal ArticleDOI

A small capacity steam-ejector refrigerator: experimental investigation of a system using ejector with movable primary nozzle

TL;DR: In this article, an experimental study of a steam-ejector refrigerator using an ejector with a primary nozzle that could be moved axially within the mixing chamber section was performed.
Journal ArticleDOI

Variable geometry ejectors and their applications in ejector refrigeration systems

TL;DR: In this article, the effect of ejector geometries on performance was analyzed for a 5kW steam-jet refrigerator with variable-geometry ejectors, including flow rates, entrainment ratio and ejector geometry.
Related Papers (5)