scispace - formally typeset
Open AccessJournal ArticleDOI

A Hybrid Reactive Power Control Method of Distributed Generation to Mitigate Voltage Rise in Low-Voltage Grid

Soo-Bin Kim, +1 more
- 21 Apr 2020 - 
- Vol. 13, Iss: 8, pp 2078
Reads0
Chats0
TLDR
A reactive power control method that combines the PF(P) method and Q(V) method is proposed that improves the voltage regulation ability of the reactivePower control, while reducing the network losses, as compared to the existing method.
Abstract
A high penetration of distributed generators, such as solar and wind power generators in low voltage network systems, impose voltage rise problems. Reactive power control of distributed generators can contribute to mitigating the voltage rise. In the existing reactive power control, reactive power was controlled using only one local variable, such as voltage at point of connection or the active power output of distributed generator. In case of PF(P) method, which provides certain power factors, depending on the active power of distributed generator, the voltage regulation ability is strong, but network losses are large. Q(V) method, which provides a certain amount of reactive power depending on the local voltage, has few network losses, but the voltage regulation ability is weak. In this paper, a reactive power control method that combines the PF(P) method and Q(V) method was proposed. The proposed method determines the reactive power output by using the active power of the distributed generator and local voltage variables together. The proposed method improves the voltage regulation ability of the reactive power control, while reducing the network losses, as compared to the existing method. The low voltage network system was modeled and simulated to evaluate the performance of the proposed method, in terms of voltage regulation ability and network losses, and the performance of the proposed method and the existing method were compared and analyzed.

read more

Citations
More filters
Journal ArticleDOI

Hybrid renewable energy based smart grid system for reactive power management and voltage profile enhancement using artificial neural network

TL;DR: In this article, the authors presented the design of an advanced smart grid model with an improved optimal variation strategy by implementing renewable energy sources, and the novelty involved in this article is design...
Journal ArticleDOI

Voltage fluctuation mitigation with coordinated OLTC and energy storage control in high PV penetrating distribution network

TL;DR: In this paper , an intelligent and real-time coordinated control of BESS and On-load Tap Changer (OLTC) was proposed to mitigate the voltage fluctuations, enhance the battery life of the BESS, and optimize the use of existing OLTCs.
Journal ArticleDOI

Adaptive Algorithm of a Tap-Changer Controller of the Power Transformer Supplying the Radial Network Reducing the Risk of Voltage Collapse

TL;DR: The goal of the authors was to create an algorithm that extends the functionality of typical transformer control algorithms, and makes it possible to increase the reserve of the voltage stability of the node, in which it is applied, thus mitigating the risk of a voltage collapse occurring.
Journal ArticleDOI

Optimal Microgrid–Interactive Reactive Power Management for Day–Ahead Operation

TL;DR: A microgrid–iterative reactive power management approach of power-electronic converter based renewable technologies for day-ahead operation is proposed, designed to be a centralised control based on local measurements which provides the optimal reactive power dispatch and minimise the total energy losses inside the microgrid and maintain the voltage profile within operational limits.
Journal ArticleDOI

A coordination control strategy for power quality enhancement of an active distribution network

TL;DR: In this article , the authors proposed a coordination control strategy which has two major objectives: (1) to regulate the apparent impedance at the PCC of the active distribution network (ADN) using coordination of DGs; (2) to use active and reactive power of battery energy storage system (BESS) for transient suppression at PCC, and (3) to improve the power factor of the DGs.
References
More filters
Journal ArticleDOI

Coordinated Active Power Curtailment of Grid Connected PV Inverters for Overvoltage Prevention

TL;DR: In this paper, the authors discuss the use of droop-based active power curtailment techniques for overvoltage prevention in radial LV feeders as a means for increasing the installed PV capacity and energy yield.
Journal ArticleDOI

Local Reactive Power Control Methods for Overvoltage Prevention of Distributed Solar Inverters in Low-Voltage Grids

TL;DR: Underlines weak points of standard reactive power strategies which are already imposed by certain grid codes, and introduces a new reactive power control method that is based on sensitivity analysis that combines two droop functions that are inherited from the standard cos φ(P) and Q(U) strategies.
Journal ArticleDOI

Improved Low Voltage Grid-Integration of Photovoltaic Systems in Germany

TL;DR: In this article, the technical and economical benefits of different active and reactive power control strategies for grid-connected photovoltaic systems in Germany are discussed, which do not require any kind of data communication between the inverter and its environment, as well as an on-load tap changer for distribution transformers.
Journal ArticleDOI

Modeling Guidelines and a Benchmark for Power System Simulation Studies of Three-Phase Single-Stage Photovoltaic Systems

TL;DR: In this paper, the main components, operation/protection modes, and control layers/schemes of medium and high-power PV systems are introduced to assist power engineers in developing circuit-based simulation models for impact assessment studies, analysis, and identification of potential issues with respect to the grid integration of PV systems.
Journal ArticleDOI

Photovoltaic Generation Penetration Limits in Radial Distribution Systems

TL;DR: In this paper, the authors present and discuss studies proving that conductor ampacity and voltage rises are limiting factors that manifest themselves under different conditions, and highlight situations in which line overloads are more restrictive than voltage rises.
Related Papers (5)