scispace - formally typeset
Journal ArticleDOI

A Novel Technique of Flow Measurement for a Conducting Liquid

Reads0
Chats0
TLDR
A novel low-cost bridge-type technique of flow measurement of a conducting liquid has been described, and the experimental characteristic of the flowmeter is found to follow the theoretical equation and has good repeatability over the entire operating zone.
Abstract
The flow rate of a conducting liquid is generally measured by an electromagnetic flowmeter, which requires a magnetization coil and a set of sensing electrodes. However, the size and cost of the flow head of this flowmeter generally become very high due to the large size of the magnetizing coil and core material. In this paper, a novel low-cost bridge-type technique of flow measurement of a conducting liquid has been described. In this technique, the lumped-parameter impedances among four electrodes placed at a radial distance apart in a flow-sensing tube form a Wheatstone bridge network. Each of these impedances is a combination of electrode polarization impedances and other impedances. Since the electrode polarization impedances are functions of the flow rate of the conducting liquid and some other parameters, the polarization impedances between two electrodes placed in two locations along the flow path of the conducting liquid may be taken as a measure of the flow rate of the liquid, with the other parameters remaining constant. The nonlinearity of these impedance variations with the flow rate is minimized by the proposed bridge-circuit near-balanced condition. The bridge is excited by a stabilized sinusoidal oscillator and balanced at the no-flow condition of the liquid. The output of the bridge network is converted into a 1- to 5-V dc signal in a signal conditioner circuit. The design aspects, theoretical analysis, and calibration data are presented in this paper. The experimental characteristic of the flowmeter is found to follow the theoretical equation and has good repeatability over the entire operating zone.

read more

Citations
More filters
Journal ArticleDOI

Further Study of the Sensing Ring Position on the Orifice-Type Capacitive Flow Sensor

TL;DR: It has been observed that for any position of the sensing ring near the orifice plate, the sensor capacitance decreases linearly with the increase of flow rate and follows the modified capacitance principle similarly as that observed in earlier work.
Proceedings ArticleDOI

Measurement of Conductive fluid flow rate with Four terminals Electrodes

TL;DR: This article has proposed an alternative flow rate measurement technique for conductive fluid that possess better sensitivity and linearity, and the theoretically and experimentally derived result is reported.
Journal ArticleDOI

Real Time PC-Based Flow Measurement Technique Using Optical Channel as a Signal Transmitting Media

TL;DR: In this paper, a PC based cost effective electro-optic type flow measurement technique is designed and developed, where the effect of heat loss on a heating element due to flowing fluid is utilized for the measurement of flow rate of liquid in the process industry.
Journal ArticleDOI

Artificial blood-flow controlling effects of inhomogeneity of twisted magnetic fields

TL;DR: In this paper, the authors used overlapped extremely low frequency (ELF) fields for the most effective blood flow control for the system and found that the inhomogeneous region obtained by overlapping the fields at 50 Hz revealed a significant difference in induced electromotive forces at the insertion points of electrodes.
Journal ArticleDOI

Microcontroller Enabled Portable Device for Flow Measurement of a Conducting Liquid

TL;DR: In this paper, the Wien bridge oscillator was used for the measurement of flow of a conducting liquid in which no excitation coil is required, and four metal electrodes were inserted into the selected zone of the flow tube, which are always in contact with the liquid and produce no obstruction to liquid flow.
References
More filters
Journal ArticleDOI

Measurement and interpretation of electrokinetic phenomena

TL;DR: The recommendations given in the report apply mainly to smooth and homogeneous solid particles and plugs in aqueous systems; some attention is paid to nonaqueous media and less ideal surfaces.
Book

Principles of measurement systems

TL;DR: In this paper, the authors present general principles of measurement systems, including reliability, choice and economics of measurement system elements, as well as the accuracy and reliability of the measurement system in the steady state.
Journal ArticleDOI

Introducing dielectrophoresis as a new force field for field-flow fractionation.

TL;DR: The validity of the model is demonstrated with human leukemia (HL-60) cells subjected to a parallel electrode array, and application of the device to separating HL-60 cells from peripheral blood mononuclear cells is shown.
Journal ArticleDOI

Linear and nonlinear properties of platinum electrode polarisation. Part 1: frequency dependence at very low frequencies

TL;DR: The polarisation impedance of the platinum electrode was measured in physiological saline over six decades of frequencies down to 1 mHz and demonstrated the validity of Schwan’s limit law of linearity at very low frequencies.
Related Papers (5)