scispace - formally typeset
Open Access

BioTechniques 30th Anniversary GEM Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification

Reads0
Chats0
TLDR
Continuous within-cycle monitoring allows rapid optimization of amplification conditions and should be particularly useful in developing new, standardized clinical assays.
Abstract
Rapid cycle DNA amplification was continuously monitored by three different fluorescence techniques. Fluorescence was monitored by (i) the double-strand-specific dye SYBR Green I, (ii) a decrease in fluorescein quenching by rhodamine after exonuclease cleavage of a dual-labeled hydrolysis probe and (iii) resonance energy transfer of fluorescein to Cy5 by adjacent hybridization probes. Fluorescence data acquired once per cycle provides rapid absolute quantification of initial template copy number. The sensitivity of SYBR Green I detection is limited by nonspecific product formation. Use of a single exonuclease hydrolysis probe or two adjacent hybridization probes offers increasing levels of specificity. In contrast to fluorescence measurement once per cycle, continuous monitoring throughout each cycle monitors the temperature dependence of fluorescence. The cumulative, irreversible signal of hydrolysis probes can be distinguished easily from the temperature-dependent, reversible signal of hybridization probes. By using SYBR Green I, product denaturation, annealing and extension can be followed within each cycle. Substantial product-to-product annealing occurs during later amplification cycles, suggesting that product annealing is a major cause of the plateau effect. Continuous within-cycle monitoring allows rapid optimization of amplification conditions and should be particularly useful in developing new, standardized clinical assays.

read more

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI

A survey of tools for the analysis of quantitative PCR (qPCR) data

TL;DR: It was showed that most tools use their own file format and only a fraction of the currently existing tools support the standardized data exchange format RDML, which needs to be adapted to allow a more streamlined and comparable analysis of qPCR data.
Journal ArticleDOI

GmWRKY27 interacts with GmMYB174 to reduce expression of GmNAC29 for stress tolerance in soybean plants

TL;DR: A valuable mechanism in soybean for regulation of the stress response by two associated transcription factors is discloses and Manipulation of these genes should facilitate improvements in stress tolerance in soy bean and other crops.
Journal ArticleDOI

Real-Time PCR for Detection and Differentiation of Entamoeba histolytica and Entamoeba dispar in Fecal Samples

TL;DR: Given the high sensitivity and specificity of the developed PCR assay, the inability of microscopy to distinguish between the two ameba species, and the time it takes to culture and subsequently differentiate entamoebae by isoenzyme analysis, this assay is more suitable than microscopy or culture to correctly diagnose intestinal E. histolytica or E. dispar infection.
Journal ArticleDOI

Detection and Quantification of Phytophthora ramorum from California Forests Using a Real-Time Polymerase Chain Reaction Assay

TL;DR: A real-time, nested polymerase chain reaction (PCR) assay was developed and tested for the detection of Phytophthora ramorum, causal agent of sudden oak death, and steered the direction of further research on this newly discovered and generalist Phydophthora species.
References
More filters
Journal ArticleDOI

Primer-directed enzymatic amplification of DNA with a thermostable DNA polymerase

TL;DR: A thermostable DNA polymerase was used in an in vitro DNA amplification procedure, the polymerase chain reaction, which significantly improves the specificity, yield, sensitivity, and length of products that can be amplified.
Journal ArticleDOI

Molecular Beacons: Probes that Fluoresce upon Hybridization

TL;DR: Novel nucleic acid probes that recognize and report the presence of specific nucleic acids in homogeneous solutions that undergo a spontaneous conforma-tional change when they hybridize to their targets are developed.
Journal ArticleDOI

Detection of specific polymerase chain reaction product by utilizing the 5'----3' exonuclease activity of Thermus aquaticus DNA polymerase.

TL;DR: The 5'----3' exonuclease activity of the thermostable enzyme Thermus aquaticus DNA polymerase may be employed in a polymerase chain reaction product detection system to generate a specific detectable signal concomitantly with amplification.
Journal ArticleDOI

Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions

TL;DR: Results obtained with this approach indicate that a kinetic approach to PCR analysis can quantitate DNA sensitively, selectively and over a large dynamic range.
Journal ArticleDOI

Oligonucleotides with fluorescent dyes at opposite ends provide a quenched probe system useful for detecting PCR product and nucleic acid hybridization.

TL;DR: It is proposed that the larger signal in the 5' nuclease PCR assay is caused by increased likelihood of cleavage by Taq DNA polymerase when the probe is hybridized to a template strand during PCR.