Feasibility and Reliability of SmartWatch to Obtain 3-Lead Electrocardiogram Recordings.
Amirali Behzadi,Alireza Sepehri Shamloo,Konstantinos Mouratis,Gerhard Hindricks,Arash Arya,Andreas Bollmann +5 more
Reads0
Chats0
TLDR
The results of this study suggested that the examined smartwatch (Apple Watch Series 4) could obtain 3-lead ECG tracings, including Einthoven leads I, II, and III by placing the smartwatch on the described positions.Abstract:
Some of the recently released smartwatch products feature a single-lead electrocardiogram (ECG) recording capability. The reliability of obtaining 3-lead ECG with smartwatches is yet to be confirmed in a large study. This study aimed to assess the feasibility and reliability of smartwatch to obtain 3-lead ECG recordings, the classical Einthoven ECG leads I-III compared to standard ECG. To record lead I, the watch was worn on the left wrist and the right index finger was placed on the digital crown for 30 s. For lead II, the watch was placed on the lower abdomen and the right index finger was placed on the digital crown for 30 s. For lead III, the same process was repeated with the left index finger. Spearman correlation and Bland-Altman tests were used for data analysis. A total of 300 smartwatch ECG tracings were successfully obtained. ECG waves' characteristics of all three leads obtained from the smartwatch had a similar duration, amplitude, and polarity compared to standard ECG. The results of this study suggested that the examined smartwatch (Apple Watch Series 4) could obtain 3-lead ECG tracings, including Einthoven leads I, II, and III by placing the smartwatch on the described positions.read more
Citations
More filters
Journal ArticleDOI
Wireless ECG and cardiac monitoring systems: State of the art, available commercial devices and useful electronic components
TL;DR: This paper aims at reviewing the solutions described in the literature, besides commercially available devices and electronic components useful to setup laboratory prototypes, at the development of a wireless ECG system.
Journal ArticleDOI
World Heart Federation Roadmap on Atrial Fibrillation - A 2020 Update
Ben Freedman,Gerhard Hindricks,Amitava Banerjee,Adrian Baranchuk,Chi Keong Ching,Xin Du,Donna Fitzsimons,Jeff S. Healey,Takanori Ikeda,Trudie Lobban,Amam Mbakwem,Calambur Narasimhan,Lis Neubeck,Peter A. Noseworthy,Daniel M Philbin,Fausto J. Pinto,Joselyn Rwebembera,Renate B. Schnabel,Jesper Hastrup Svendsen,Luis Aguinaga,Elena Arbelo,Michael Böhm,Hasan Ali Farhan,FD Richard Hobbs,Antoni Martínez-Rubio,Claudio Militello,Nitish Naik,Jean Jacques Noubiap,Pablo Perel,Daniel J. Piñeiro,Antonio Luiz Pinho Ribeiro,Janina Stępińska +31 more
TL;DR: The World Heart Federation (WHF) initiated a Roadmap initiative in 2015 to reduce the global burden of cardiovascular disease and resultant burgeoning of healthcare costs as mentioned in this paper, where the goal was to provide guidance on priority interventions that are feasible in multiple countries, and to identify roadblocks and potential strategies to overcome them.
Journal ArticleDOI
Accuracy of the Apple Watch iECG in Children With and Without Congenital Heart Disease
M. Kobel,P Kalden,Anna Michaelis,Franziska Markel,S Mensch,Michael Weidenbach,Frank-Thomas Riede,F. Löffelbein,Andreas Bollmann,Alireza Sepehri Shamloo,Ingo Dähnert,Roman Gebauer,Christian Paech +12 more
TL;DR: In this article, the authors evaluated the agreement of measured values of rate, interval, and amplitude with those obtained by a diagnostic quality ECG recording to an Apple Watch iECG in children with and without congenital heart disease.
Journal ArticleDOI
Regulatory, Legal, and Market Aspects of Smart Wearables for Cardiac Monitoring.
Jan B. Brönneke,Jennifer Müller,Konstantinos Mouratis,Julia Hagen,Ariel Dora Stern,Ariel Dora Stern +5 more
TL;DR: In this article, the authors present a brief overview of the existing clinical studies regarding the use of smart wearables in cardiac monitoring and provide insight into the main regulatory and legal aspects that need to be considered when such products are intended to be used in a health care setting.
Journal ArticleDOI
Wearable-basierte Detektion von Arrhythmien
C. Veltmann,Joachim R. Ehrlich,Ulrich M. Gassner,Benjamin Meder,Martin Möckel,Peter W. Radke,Eberhard P. Scholz,Hendrik Schneider,Christoph Stellbrink,David Duncker +9 more
TL;DR: In this paper, a position papier is presented, einen Uberblick zur aktuellen Datenlage und zum Einsatz der Wearables bei der Detektion von symptomatischen and asymptomatische Arrhythmien zu geben.
References
More filters
Journal ArticleDOI
Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation
Marco V Perez,Kenneth W. Mahaffey,Haley Hedlin,John S. Rumsfeld,Ariadna Garcia,Todd A. Ferris,Vidhya Balasubramanian,Andrea M. Russo,Amol Rajmane,Lauren Cheung,Grace Hung,Justin Lee,Peter R. Kowey,Nisha Talati,Divya Nag,Santosh Gummidipundi,Alexis L. Beatty,Mellanie True Hills,Sumbul A Desai,Christopher B. Granger,Manisha Desai,Mintu P. Turakhia,Apple Heart Study Investigators +22 more
TL;DR: This siteless study design provides a foundation for large-scale pragmatic studies in which outcomes or adherence can be reliably assessed with user-owned devices and the probability of receiving an irregular pulse notification was low.
Journal ArticleDOI
AHA/ACCF/HRS Recommendations for the Standardization and Interpretation of the Electrocardiogram. Part IV: The ST Segment, T and U Waves, and the QT Interval A Scientific Statement From the American Heart Association Electrocardiography and Arrhythmias Committee, Council on Clinical Cardiology; the American College of Cardiology; and the Heart Rhythm Society
TL;DR: The present article is the fourth in a series of 6 documents focused on providing current guidelines for the standardization and interpretation of the electrocardiogram (ECG) and discusses abnormalities in the ST segment, T wave, and duration of the QT interval reflect abnormalities in ventricular repolarization.
Journal ArticleDOI
Recommendations for standardization and specifications in automated electrocardiography: bandwidth and digital signal processing. A report for health professionals by an ad hoc writing group of the Committee on Electrocardiography and Cardiac Electrophysiology of the Council on Clinical Cardiology, American Heart Association.
TL;DR: Technologic advances and published studies point to the need to reevaluate requirements for recording and analysis of electrocardiographic (ECG) data, and high-frequency components and lowamplitude signals in the ECG known primarily to researchers are now regarded with wider interest.
Journal ArticleDOI
Mobile Photoplethysmographic Technology to Detect Atrial Fibrillation
Yutao Guo,Hao Wang,Hui Zhang,Tong Liu,Zhaoguang Liang,Yunlong Xia,Li Yan,Yunli Xing,Haili Shi,Shuyan Li,Yanxia Liu,Fan Liu,Mei Feng,Yundai Chen,Gregory Y.H. Lip,Mafa Ii Investigators +15 more
TL;DR: Continuous home monitoring with smart device–based PPG technology could be a feasible approach for AF screening and detection, as well as early interventions to reduce stroke and other AF-related complications.
Journal ArticleDOI
The Measurement of the QT Interval
TL;DR: In this review, the history of the measurement of the QT interval, its underlying pathophysiological mechanisms and the current standards of the measurements are delineated, a glimpse into the future is provided, and several issues troubling accurate measurement are discussed, including the lead choice, U-waves, determination of the end of the T-wave and the definition of normal and aberrant QT intervals.
Related Papers (5)
Evaluation of the Accuracy of ECG Captured by CardioChip through Comparison of Lead I Recording to a Standard 12-Lead ECG Recording Device.
Chi-In Lo,Chi-In Lo,Sheng-Shiung Chang,Sheng-Shiung Chang,Jui-Peng Tsai,Jui-Peng Tsai,Jen Yuan Kuo,Jen Yuan Kuo,Ying-Ju Chen,Ming-Yuan Huang,Ming-Yuan Huang,Chao-Hsiung Lee,Chao-Hsiung Lee,Kuo-Tzu Sung,Kuo-Tzu Sung,Chung-Lieh Hung,Chung-Lieh Hung,Charles Jia-Yin Hou,Charles Jia-Yin Hou,Edward Lai,Hung-I Yeh,Hung-I Yeh,Wen-Ling Chang,Wen-Han Chang +23 more
Designing of a single arm single lead ecg system for wet and dry electrode: a comparison with traditional system
Gautham A,V. Karthik Raj +1 more