scispace - formally typeset
Journal ArticleDOI

Frequency domain analysis of three phase linear current regulators

Reads0
Chats0
TLDR
In this article, a technique for interpreting the stationary/rotating frame transformations as modulation processes in the Laplace domain is presented, which moves the control function from one part of the frequency spectrum to another.
Abstract
Stationary frame linear PI current regulators are conventionally regarded as unsatisfactory for AC systems because they cannot eliminate steady state errors. Consequently, synchronous frame regulators are perceived to be superior, since they achieve zero steady state error by acting on DC signals in a rotating frame of reference. However, a synchronous frame regulator is more complex, and requires in particular a way of transforming a measured stationary frame AC current (or error) to rotating frame DC quantities, and transforming the resultant control action back to the stationary frame for implementation. This paper presents a technique for interpreting the stationary/rotating frame transformations as modulation processes in the Laplace domain which move the control function from one part of the frequency spectrum to another. The technique is used to compare stationary and synchronous frame PI regulators on a common basis to better understand the advantages of a synchronous frame regulator, and then to develop a new form of stationary frame resonant regulator which achieves zero steady state error without requiring the complex transformations of a synchronous frame regulator. The performance of this new regulator is evaluated and found to be equivalent to that of the synchronous frame PI regulator.

read more

Citations
More filters
Book ChapterDOI

Tuning PID Control Systems with Experimental Validations

TL;DR: In this chapter, sensitivity functions in feedback control systems are introduced to measure the closed-loop control system performance against set-point following, disturbance rejection and noise attenuation in the frequency domain.
Proceedings ArticleDOI

Estrategia De Control Por Curva De Caída Con Reducido Costo Computacional Para Inversores Monofásicos En Paralelo

TL;DR: In this article, a control strategy for curva de caida utilizing un lazo de impedancia virtual for lograr a caracteristica predominantemente inductiva a frecuencia fundamental is presented.
Book ChapterDOI

Modelling of the Wind Turbine Generator and the Power Electronic Grid Simulator

TL;DR: This chapter focusses on the time domain modelling of the CGI and the WTG, the grid simulator and the power electronic devices that are implemented in PSCAD/EMTDC.
Proceedings ArticleDOI

A control strategy for hybrid series active power filter based on resonant compensators

TL;DR: This paper proposes a control strategy for Hybrid Active Series Power Filter (HASPF) based on a P+Resonant compensator that ensures multiple frequencies tuning by using only one passive filter.
Proceedings ArticleDOI

Comparative Study of Two Adaptive Resonant Controllers in a Modular Multilevel Converter

TL;DR: This paper investigates adaptive proportional-resonant controllers in stationary reference frame used for suppression of second harmonic circulating current in the modular multilevel converter especially for lower controller bandwidth.
References
More filters
Journal ArticleDOI

Current control techniques for three-phase voltage-source PWM converters: a survey

TL;DR: Current control techniques for three-phase voltage-source pulsewidth modulated converters, including bang-bang (hysteresis, delta modulation) controllers and predictive controllers with on-line optimization are reviewed.
Book

Vector Control and Dynamics of AC Drives

TL;DR: In this article, the authors present a d-q model for solid state power converters and present a complex vector analysis of induction machines and synchronous machines with respect to vector control and field orientation.
Journal ArticleDOI

Model-based current control of AC machines using the internal model control method

TL;DR: In this article, the internal model control (IMC) method is introduced and applied to AC machine current control, and it is shown that IMC is able to outperform PI control with and without decoupling with respect to dq variable interaction in the presence of parameter deviations.
Journal ArticleDOI

A New Synchronous Current Regulator and an Analysis of Current-Regulated PWM Inverters

TL;DR: In this article, a detailed model for the stationary and synchronous sine-triangle current regulators is presented, and the results demonstrate the limitations of the two most often used current regulators and the robustness of the synchronous current regulator.
Related Papers (5)