scispace - formally typeset
Journal ArticleDOI

Human Life Signs Detection Using High-Sensitivity Pulsed Laser Vibrometer

Reads0
Chats0
TLDR
In this article, a high surface displacement detection sensitivity of the photo-electromotive-force (photo-EMF) pulsed laser vibrometer, combined with its tolerance to the presence and moderate temporal variations of optical speckles in the light beams, allows the detection of human heartbeats, breathing, and gross physical movement from essentially any part of a human subject's surface, even in the presence of clothing, all the while without limiting the interrogation points to specific locations like the chest and carotid areas.
Abstract
We demonstrate experimentally the detection, in a remote and noncontact manner, of human life signs using a high-sensitivity pulsed laser vibrometer. The high surface displacement detection sensitivity of the photo-electromotive-force (photo-EMF) pulsed laser vibrometer, combined with its tolerance to the presence and moderate temporal variations of optical speckles in the light beams, allows the detection of human heartbeats, breathing, and gross physical movement from essentially any part of a human subject's surface, even in the presence of clothing, all the while without limiting the interrogation points to specific locations like the chest and carotid areas. In contrast to conventional Michelson interferometer-based laser vibrometers, the photo-EMF pulsed laser vibrometer (PPLV) does not require the use of retroreflective tapes or special electronic filtering to retrieve vividly the biological subject's life signs. Experimental results demonstrating the detection of life signs from various parts of biological subjects' bodies, with or without the coverage of clothing are presented. We also demonstrate the monitoring of a human subject's heart movements by interrogating the back of his/her hand. Results from using PPLV to determine extremity blood circulation at various levels of proximal occluding pressures are also presented.

read more

Citations
More filters
Journal ArticleDOI

Ambient and Unobtrusive Cardiorespiratory Monitoring Techniques

TL;DR: This review provides a systematic and comprehensive review over the current state of the field of ambient and unobtrusive cardiorespiratory monitoring and systematically analyzes similarities and differences between these methods with respect to the physiological and physical effects they sense as well as the resulting implications.
Journal ArticleDOI

Radar-Based Heart Sound Detection

TL;DR: Using the detected heart sounds considerably improves radar-based heartbeat monitoring, while the achieved performance is also competitive to phonocardiography.
Journal ArticleDOI

Non-contact physiological monitoring of preterm infants in the Neonatal Intensive Care Unit.

TL;DR: A clinical study to evaluate the accuracy and the proportion of time that heart rate and respiratory rate can be estimated from preterm infants using only a video camera in a clinical environment, without interfering with regular patient care and proposes signal quality assessment algorithms to discriminate between clinically acceptable and noisy signals.
Journal ArticleDOI

Flexible Ultrathin Single-Crystalline Perovskite Photodetector.

TL;DR: Ultrathin single-crystalline perovskite ultrathin films are introduced as the active layer and a high-performance flexible photodetector with prevailing bending reliability is demonstrated and all its optoelectronic characteristics resume after being bent over thousands of times.
Journal ArticleDOI

Crystal growth technology of binary and ternary II–VI semiconductors for photonic applications

TL;DR: In this paper, the bulk crystal growth technology of binary and ternary II-VI chalcogenides for photonic applications of II-V semiconductors is discussed.
References
More filters
Journal Article

Photorefractive Materials and Their Applications

Peter Günter, +1 more
- 01 Jan 2006 - 
TL;DR: This is the first volume of a set of three within the Springer Series in Optical Sciences, and is devoted to photorefractive effects, photoreFractive materials, and their applications.
Journal ArticleDOI

Diagnostic accuracy of seismocardiography compared with electrocardiography for the anatomic and physiologic diagnosis of coronary artery disease during exercise testing

TL;DR: Seismocardiography significantly improved sensitivity for the detection of anatomic and physiologic CAD and may be a clinically useful adjunct in exercise stress testing.
Journal ArticleDOI

Sensitivity of non-steady-state photoelectromotive force-based adaptive photodetectors and characterization techniques.

TL;DR: The light-to-electricity conversion efficiency of the non-steady-state photoelectromotive force effect and its threshold sensitivity for the detection of phase-modulated optical signals and space-charge electric fields are evaluated.
Journal ArticleDOI

ECG techniques and technologies.

TL;DR: The electrocardiogram (ECG) continues to be a critical component of the evaluation of patients who have signs and symptoms of emergency cardiac conditions and an expansion in the use of additional leads allows clinicians to extract more and more information from the cardiac electrical activity.
Related Papers (5)