scispace - formally typeset
Open AccessJournal ArticleDOI

Low-Noise, Low-Power Readout IC for Two-Electrode ECG Recording Using Common-Mode Charge Pump for Robust 20-VPP Common-Mode Interference

Reads0
Chats0
TLDR
In this article , a low-noise and power readout integrated circuit (IC) for two-electrode electrocardiogram (ECG) recording is developed using a commonmode charge pump (CMCP) for a robust 20-VPP common-mode interference (CMI).
Abstract
A low-noise and -power readout integrated circuit (IC) for two-electrode electrocardiogram (ECG) recording is developed in this study using a common-mode charge pump (CMCP) for a robust 20-VPP common-mode interference (CMI). Two-electrode ECG recording offers more comfort than three-electrode ECG recording. Contrasting to the three-electrode ECG recording, the two-electrode ECG recording is affected by CMI during measurements; the intervention of a large CMI will distort the ECG signal measurement. To achieve robustness for the CMI, the proposed ECG readout IC adopts CMCP—it uses switched capacitors that store and subtract CMI by control logic. In this paper, a window comparator structure is applied to CMCP to obtain a signal with less distortion. The window voltage ranges were set between the input common-mode ranges in which IA can operate. Therefore, a signal with less distortion was obtained by stopping the operation of CMCP between the window voltage ranges. It also reduced additional current consumption. To achieve this, the proposed circuit is implemented using a chopper stabilization technique. The chopper implemented in the amplifier can reduce low-frequency noise components, such as 1/f noise, and it comprises a CMCP, current feedback instrumentation amplifier, QRS peak detector, relaxation oscillator, voltage reference, timing generator, and serial peripheral interface on a single chip. The proposed circuit was designed using a standard 0.18 μm CMOS process with an active area of 0.54 mm2. The proposed CMCP achieves a CMI robustness of 20 VPP at 60 Hz. The measured input-referred noise level was 119 nV/√Hz at 1 Hz, and the power consumption was 23.83 μW with a 1.8 V power supply.

read more

Content maybe subject to copyright    Report

References
More filters
Journal ArticleDOI

Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review

TL;DR: This paper explores the use of dry/noncontact electrodes for clinical use by first explaining the electrical models for dry, insulated and noncontact electrodes and show the performance limits, along with measured data and an extensive review of the latest dry electrode developments in the literature.
Journal ArticleDOI

A Chopper Current-Feedback Instrumentation Amplifier With a 1 mHz $1/f$ Noise Corner and an AC-Coupled Ripple Reduction Loop

TL;DR: This paper presents a chopper instrumentation amplifier for interfacing precision thermistor bridges that employs a continuous-time AC-coupled ripple reduction loop, which reduces chopper ripple to levels below the amplifier's own input-referred noise.
Journal ArticleDOI

Prognostic value of ECG findings for total, cardiovascular disease, and coronary heart disease death in men and women.

TL;DR: Although the prevalence of major abnormalities in general was comparable between sexes, women had more ischaemic findings, ST segment changes, and abnormal T waves on their baseline ECG, while men showed more arrhythmias, bundle branch blocks, and left ventricular hypertrophy.
Journal ArticleDOI

Scalable Digital Neuromorphic Architecture for Large-Scale Biophysically Meaningful Neural Network With Multi-Compartment Neurons

TL;DR: The experimental results demonstrate that the proposed work can provide an efficient model and architecture for large-scale biologically meaningful networks, while the hardware synthesis results demonstrate low area utilization and high computational speed that supports the scalability of the approach.