scispace - formally typeset
Journal ArticleDOI

Single-shot spatially modulated Stokes polarimeter based on a GRIN lens

Jintao Chang, +4 more
- 01 May 2014 - 
- Vol. 39, Iss: 9, pp 2656-2659
TLDR
A new polarimeter for the simultaneous measurement of all Stokes parameters in a single shot is presented, which takes advantage of the continuous spatial distributions of birefringence value and the fast axis direction of a GRIN lens and derives the state of polarization (SOP) of the incident beam from the characteristic patterns on the CCD images.
Abstract
A new polarimeter for the simultaneous measurement of all Stokes parameters in a single shot is presented. It consists of only a gradient index (GRIN) lens, a polarizer, an imaging lens, and a CCD, without mechanical movements, electrical signal modulation, or the division of amplitude components. This design takes advantage of the continuous spatial distributions of birefringence value and the fast axis direction of a GRIN lens and derives the state of polarization (SOP) of the incident beam from the characteristic patterns on the CCD images. Tests show that this polarimeter is very accurate even with low-resolution images. It is versatile and adapts to light sources of different wavelengths. It is also very stable, robust, low cost, and simple to use.

read more

Citations
More filters
Journal ArticleDOI

Polarized light imaging in biomedicine: emerging Mueller matrix methodologies for bulk tissue assessment

TL;DR: Some of the recent progress in tissue polarimetry are reviewed, illustrative application examples are provided, and an outlook to the future of polarized light imaging in bulk biological tissues is offered.
Journal ArticleDOI

Mueller polarimetric imaging for surgical and diagnostic applications: a review

TL;DR: The basis of the Stokes-Mueller formulism, interpretation methods of Mueller matrices into fundamental polarization properties, polarization properties of biological tissues, and considerations in the construction of Mueller polarimetric imaging devices for surgical and diagnostic applications are introduced.
Journal ArticleDOI

Polarisation optics for biomedical and clinical applications: a review.

TL;DR: A review of methodologies and applications related to tissue polarimetry, with an emphasis on the adoption of the Stokes-Mueller formalism, is presented in this article, where several recent breakthroughs, development trends, and potential multimodal uses in conjunction with other techniques are also presented.
Journal ArticleDOI

Differentiation of suspended particles by polarized light scattering at 120

TL;DR: Experiments show that by carefully choosing the incident polarization state and analyzing the polarization features of the scattered light at 120°, these particles can be effectively differentiated.
Journal ArticleDOI

Linear polarization optimized Stokes polarimeter based on four-quadrant detector

TL;DR: A Stokes polarimeter with optimal linear polarization measurements based on a 4QD is reported on, capable of simultaneous measurements of fast varying SOP with improved performance for the linear polarizations.
References
More filters
Book

Ellipsometry and polarized light

TL;DR: In this article, the polarization of light waves and propagation of polarized light through polarizing optical systems are discussed. But the authors focus on the application of ellipsometry in the field of measurement in ellipsometer systems.
Journal ArticleDOI

Interpretation of Mueller matrices based on polar decomposition

TL;DR: In this paper, the authors decompose a Mueller matrix into a sequence of three matrix factors: a diattenuator, followed by a retarder, then followed by depolarizer.
Journal ArticleDOI

Optimization of retardance for a complete Stokes polarimeter.

TL;DR: Two figures of merit based on singular value decomposition are presented, which can be used to assess the noise immunity of a complete Stokes polarimeter, used to optimize a polarimeter featuring a rotatable retarder and a fixed polarizer.
Journal ArticleDOI

Design of optimal polarimeters: maximization of signal-to-noise ratio and minimization of systematic error.

TL;DR: The relationship between system condition and signal-to-noise ratio (SNR) in reconstructed Stokes parameter images is investigated for rotating compensator, variable retardance, and rotating analyzer Stokes vector (SV) polarimeters and the concept of nonorthogonal bases, frames, and tight frames is introduced to describe the operation of SV polarimeters.
Journal ArticleDOI

Optimized Mueller polarimeter with liquid crystals.

TL;DR: A Mueller polarimeter is demonstrated in which the polarization-state generator and analyzer are both composed of a linear polarizer and two liquid-crystal variable retarders to optimize the accuracy of the final results by minimization of the condition numbers of the modulation and analysis matrices.
Related Papers (5)