scispace - formally typeset
Open AccessJournal ArticleDOI

Validation Study of the Accuracy of Echocardiographic Measurements of Systemic Blood Flow Volume in Newborn Infants

Reads0
Chats0
TLDR
Echocardiographic assessment of superior vena caval flow is of limited accuracy in this population, casting doubt on the utility of the measurement for diagnostic decision making.
Abstract
Background The echocardiographic assessment of circulatory function in sick newborn infants has the potential to improve patient care. However, measurements are prone to error and have not been sufficiently validated. Phase-contrast magnetic resonance imaging (MRI) provides highly validated measures of blood flow and has recently been applied to the newborn population. The aim of this study was to validate measures of left ventricular output and superior vena caval flow volume in newborn infants. Methods Echocardiographic and MRI assessments were performed within 1 working day of each other in a cohort of newborn infants. Results Examinations were performed in 49 infants with a median corrected gestational age at scan of 34.43 weeks (range, 27.43–40 weeks) and a median weight at scan of 1,880 g (range, 660–3,760 g). Echocardiographic assessment of left ventricular output showed a strong correlation with MRI assessment ( R 2  = 0.83; mean bias, −9.6 mL/kg/min; limits of agreement, −79.6 to +60.0 mL/kg/min; repeatability index, 28.2%). Echocardiographic assessment of superior vena caval flow showed a poor correlation with MRI assessment ( R 2  = 0.22; mean bias, −13.7 mL/kg/min; limits of agreement, −89.1 to +61.7 mL/kg/min; repeatability index, 68.0%). Calculating superior vena caval flow volume from an axial area measurement and applying a 50% reduction to stroke distance to compensate for overestimation gave a slightly improved correlation with MRI ( R 2  = 0.29; mean bias, 2.6 mL/kg/min; limits of agreement, −53.4 to +58.6 mL/kg/min; repeatability index, 54.5%). Conclusions Echocardiographic assessment of left ventricular output appears relatively robust in newborn infant. Echocardiographic assessment of superior vena caval flow is of limited accuracy in this population, casting doubt on the utility of the measurement for diagnostic decision making.

read more

Citations
More filters
Journal ArticleDOI

Echocardiographic Evaluation of Ventricular Function-For the Neonatologist and Pediatric Intensivist.

TL;DR: The normal values for most of the parameters used to assess cardiac function in term neonates and children have now been established.
Journal ArticleDOI

Echocardiographic Evaluation of Hemodynamics in Neonates and Children.

TL;DR: The echocardiography has the ability to provide longitudinal functional assessment in real time, which makes it an ideal tool for monitoring hemodynamic assessment in neonates and children and it is now being used in clinical decision making for patients with hemodynamic instability.
Journal ArticleDOI

Accuracy and precision of minimally-invasive cardiac output monitoring in children: a systematic review and meta-analysis

TL;DR: A comprehensive search of the medical literature in PubMed, Cochrane Library of Clinical Trials, Scopus, and Web of Science assessing the accuracy and precision of all minimally-invasive CO monitoring systems used in children when compared with CO monitoring reference methods found no independent effects of study characteristics on weighted mean difference between reference and tested methods.
References
More filters
Journal ArticleDOI

Statistical methods for assessing agreement between two methods of clinical measurement.

TL;DR: An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Journal Article

Akufo and ibarapa.

Beckett Ah, +2 more
- 06 Feb 1965 - 
Journal ArticleDOI

Statistical methods for assessing agreement between two methods of clinical measurement

TL;DR: In this article, an alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability, which is often used in clinical comparison of a new measurement technique with an established one.
Journal ArticleDOI

Superior vena cava flow in newborn infants: a novel marker of systemic blood flow

TL;DR: This technique can assess blood flow from the upper body, including the brain, in the crucial early postnatal period, and might allow more accurate assessment of the status of systemic blood flow and response to treatment.
Journal ArticleDOI

Towards rational management of the patent ductus arteriosus: the need for disease staging

TL;DR: Perspective on the review by Bose and Laughon (see page 498) and the author's own views on the book and its reception.
Related Papers (5)