Journal ArticleDOI
TL;DR: PLA/15%HA porous scaffolds obtained by 3D-printing with shape recovery of 98% may be used as self-fitting implant for small bone defect replacement owing to SME and were found to withstand up to three compression-heating-compression cycles without delamination.
Abstract: In the present work polylactide (PLA)/15wt% hydroxyapatite (HA) porous scaffolds with pre-modeled structure were obtained by 3D-printing by fused filament fabrication. Composite filament was obtained by extrusion. Mechanical properties, structural characteristics and shape memory effect (SME) were studied. Direct heating was used for activation of SME. The average pore size and porosity of the scaffolds were 700μm and 30vol%, respectively. Dispersed particles of HA acted as nucleation centers during the ordering of PLA molecular chains and formed an additional rigid fixed phase that reduced molecular mobility, which led to a shift of the onset of recovery stress growth from 53 to 57°C. A more rapid development of stresses was observed for PLA/HA composites with the maximum recovery stress of 3.0MPa at 70°C. Ceramic particles inhibited the growth of cracks during compression-heating-compression cycles when porous PLA/HA 3D-scaffolds recovered their initial shape. Shape recovery at the last cycle was about 96%. SME during heating may have resulted in "self-healing" of scaffold by narrowing the cracks. PLA/HA 3D-scaffolds were found to withstand up to three compression-heating-compression cycles without delamination. It was shown that PLA/15%HA porous scaffolds obtained by 3D-printing with shape recovery of 98% may be used as self-fitting implant for small bone defect replacement owing to SME.

356 citations


Journal ArticleDOI
TL;DR: Zn-0.5Mg is the most promising material for stent applications with a good combination of strength, ductility, strain hardening exponent and an appropriate rate of loss of mechanical integrity during degradation.
Abstract: The search for a degradable metal simultaneously showing mechanical properties equal or higher to that of stainless steel and uniform degradation is still an open challenge. Several magnesium-based alloys have been studied, but their degradation rate has proved to be too fast and rarely homogeneous. Fe-based alloys show appropriate mechanical properties but very low degradation rate. In the present work, four novel Zn-Mg and two Zn-Al binary alloys were investigated as potential biodegradable materials for stent applications. The alloys were developed by casting process and homogenized at 350°C for 48h followed by hot extrusion at 250°C. Tube extrusion was performed at 300°C to produce tubes with outer/inner diameter of 4/1.5mm as precursors for biodegradable stents. Corrosion tests were performed using Hanks׳ modified solution. Extruded alloys exhibited slightly superior corrosion resistance and slower degradation rate than those of their cast counterparts, but all had corrosion rates roughly half that of a standard purity Mg control. Hot extrusion of Zn-Mg alloys shifted the corrosion regime from localized pitting to more uniform erosion, mainly due to the refinement of second phase particles. Zn-0.5Mg is the most promising material for stent applications with a good combination of strength, ductility, strain hardening exponent and an appropriate rate of loss of mechanical integrity during degradation. An EBSD analysis in the vicinity of the laser cut Zn-0.5Mg tube found no grain coarsening or texture modification confirming that, after laser cutting, the grain size and texture orientation of the final stent remains unchanged. This work shows the potential for Zn alloys to be considered for stent applications.

294 citations


Journal ArticleDOI
TL;DR: The review shows that sol-gel dip coatings and electrochemical deposition were able to obtain the uniform and homogeneous coating thickness and high adherent biocompatible coatings even in complex shapes.
Abstract: New promising techniques for depositing biocompatible hydroxyapatite-based coatings on biocompatible metal substrates for biomedical applications have continuously been exploited for more than two decades. Currently, various experimental deposition processes have been employed. In this review, the two most frequently used deposition processes will be discussed: a sol-gel dip coating and an electrochemical deposition. This study deliberates the surface morphologies and chemical composition, mechanical performance and biological responses of sol-gel dip coating as well as the electrochemical deposition for two different sample conditions, with and without coating. The review shows that sol-gel dip coatings and electrochemical deposition were able to obtain the uniform and homogeneous coating thickness and high adherent biocompatible coatings even in complex shapes. It has been accepted that both coating techniques improve bone strength and initial osseointegration rate. The main advantages and limitations of those techniques of hydroxyapatite-based coatings are presented. Furthermore, the most significant challenges and critical issues are also highlighted.

271 citations


Journal ArticleDOI
TL;DR: CAM composites presented moderate FS, high T and antagonist friendly behavior, and glass-ceramics demonstrated the most favorable DR and lowest TBW on the material side.
Abstract: Objectives: To determine the mechanical and optical properties of CAD/CAM composites (LAVA Ultimate, Cerasmart, Shofu Block and two exp. CAD/CAM composites), a hybrid material (VITA Enamic), a leucite (IPS Empress CAD) and a lithium disilicate glass-ceramic (IPS e.max CAD). Materials and methods: Three-point flexural strength (FS) was investigated according ISO 6872:2008 (N=240/n=30). Two-body wear (TBW) was analyzed in a chewing simulator (1,200,000 cycles, 50 N, 5 degrees/55 degrees C) using human teeth as antagonists (N=120/n=15). Quantitative analysis of wear was carried out with a 3D-scanner and associated matching software. Discoloration rate (DR) after 14 days of storage in cress, curry, red wine, and distilled water (N=384/n=12), and translucency (T) (N=384/n=48) of CAD/CAM materials were measured in a spectrophotometer (400-700 nm wavelength). Data were analyzed using two-/one-way ANOVA with Scheffe post-hoc test, Kruskal Wallis-H test, and linear mixed models (alpha=0.05). Results: IPS e.max CAD showed the highest FS (p curry>cress>distilled water) exerted the highest influence on DR (p<0.001), closely followed by CAD/CAM material. Glass-ceramics showed lower DR than CAD/CAM composites (p<0.001). Conclusions: CAD/CAM composites presented moderate FS, high T and antagonist friendly behavior. Glass-ceramic demonstrated the most favorable DR and lowest TBW on the material side. (C) 2015 Elsevier Ltd. All rights reserved.

209 citations


Journal ArticleDOI
TL;DR: Among TPMS-based scaffolds, P and D surfaces were subjected to gradient modeling to explore the mechanical responses for stretching and bending dominated deformations, respectively and the results were compared to their corresponding uniform porosity structures.
Abstract: Since the advent of additive manufacturing techniques, triply periodic minimal surfaces have emerged as a novel tool for designing porous scaffolds. Whereas scaffolds are expected to provide multifunctional performance, spatially changing pore patterns have been a promising approach to integrate mechanical characteristics of different architectures into a unique scaffold. Smooth morphological variations are also frequently seen in nature particularly in bone and cartilage structures and can be inspiring for designing of artificial tissues. In this study, we carried out experimental and numerical procedures to uncover the mechanical properties and deformation mechanisms of linearly graded porosity scaffolds for two different mathematically defined pore structures. Among TPMS-based scaffolds, P and D surfaces were subjected to gradient modeling to explore the mechanical responses for stretching and bending dominated deformations, respectively. Moreover, the results were compared to their corresponding uniform porosity structures. Mechanical properties were found to be by far greater for the stretching dominated structure (P-Surface). For bending dominated architecture (D-Surface), although there was no global fracture for uniform structures, graded structure showed a brittle fracture at 0.08 strain. A layer by layer deformation mechanism for stretching dominated structure was observed. For bending dominated scaffolds, deformation was accompanied by development of 45° shearing bands. Finite element simulations were also performed and the results showed a good agreement with the experimental observations.

186 citations


Journal ArticleDOI
TL;DR: The results indicated that the underlying fatigue mechanism for the three kinds of meshes is the interaction of cyclic ratcheting and fatigue crack growth on the struts, which is closely related to cumulative effect of buckling and bending deformation of the strut.
Abstract: Additive manufacturing technique is a promising approach for fabricating cellular bone substitutes such as trabecular and cortical bones because of the ability to adjust process parameters to fabricate different shapes and inner structures. Considering the long term safe application in human body, the metallic cellular implants are expected to exhibit superior fatigue property. The objective of the study was to study the influence of cell shape on the compressive fatigue behavior of Ti-6Al-4V mesh arrays fabricated by electron beam melting. The results indicated that the underlying fatigue mechanism for the three kinds of meshes (cubic, G7 and rhombic dodecahedron) is the interaction of cyclic ratcheting and fatigue crack growth on the struts, which is closely related to cumulative effect of buckling and bending deformation of the strut. By increasing the buckling deformation on the struts through cell shape design, the cyclic ratcheting rate of the meshes during cyclic deformation was decreased and accordingly, the compressive fatigue strength was increased. With increasing bending deformation of struts, fatigue crack growth in struts contributed more to the fatigue damage of meshes. Rough surface and pores contained in the struts significantly deteriorated the compressive fatigue strength of the struts. By optimizing the buckling and bending deformation through cell shape design, Ti-6Al-4V alloy cellular solids with high fatigue strength and low modulus can be fabricated by the EBM technique.

181 citations


Journal ArticleDOI
TL;DR: Heat-treatment of the Ti-6Al-4V parts at 800°C for 2h proved to be the best condition, which improved the ductility of the samples while only slightly reducing their strength.
Abstract: Ti-6Al-4V parts obtained by selective laser melting typically have an acicular α' martensitic microstructure whose ductility is low. Thus, post-heat treatments are useful for increasing ductility. In this work, the effects of sub-β-transus heat treatments on the mechanical properties of Ti-6Al-4V parts with porous structures are correlated with martensite α' phase decomposition. The precipitation of β phase and the gradual transformation of α' into α phase by the diffusion of excess vanadium from α' to β phase are proposed to be the main events of martensite α' phase decomposition in parts fabricated by selective laser melting. The heat treatment performed at 650°C for 1h produced no microstructural changes, but the samples treated for at the same temperature 2h showed a fine precipitation of β phase along the α' needle boundaries. The heat treatment performed at 800°C for 1 or 2h produced a fine α+β microstructure, in which β phase are present as particles fewer in number and larger in size, when compared with the ones present in the sample heat-treated at 650°C for 2h. Heat-treatment of the parts at 800°C for 2h proved to be the best condition, which improved the ductility of the samples while only slightly reducing their strength.

177 citations


Journal ArticleDOI
TL;DR: The effect of LTD depends on some methodological parameters indicating that aging time higher than 20h; pressure ≥2bar and temperature of 134°C are ideal parameters to promote LTD effects, and that those effect are only observed when more than 50% m-phase content is observed.
Abstract: The aim of this study was to systematically review the literature to assess if low-temperature degradation (LTD) simulation in autoclave promotes deleterious impact on the mechanical properties and superficial characteristics of Y-TZP ceramics compared to the non-aged protocol. The MEDLINE via PubMed electronic database was searched with included peer-reviewed publications in English language and with no publication year limit. From 413 potentially eligible studies, 49 were selected for full-text analysis, 19 were included in the systematic review with 12 considered in the meta-analysis. Two reviewers independently selected the studies, extracted the data, and assessed the risk of bias. Statistical analysis was performed using RevMan 5.1, with random effects model, at a significance level of p 20h. However, for shorter aging times (≤20h), there was no difference between groups. Pressure subgroup analysis presented a statistical difference (p<0.05) only when a pressure ≥2bar was employed, favoring non-aging group. Temperature subgroup analysis showed a statistical difference (p<0.05) only when temperature=134°C was used, favoring the non-aging group. M-phase % content analysis presented statistical difference (p<0.05) when more than 50% of m-phase content was observed, favoring non-aging group. High heterogeneity was found in some comparisons. Aging in autoclave promoted low-temperature degradation, impacting deleteriously on mechanical properties of Y-TZP ceramics. However, the effect of LTD depends on some methodological parameters indicating that aging time higher than 20h; pressure ≥2bar and temperature of 134°C are ideal parameters to promote LTD effects, and that those effect are only observed when more than 50% m-phase content is observed.

142 citations


Journal ArticleDOI
TL;DR: With enhanced mechanical properties as well as good wettability and cytocompatibility, PLA/GO-g-PEG composite nanofibers have the potential to be used as scaffolds in tissue engineering.
Abstract: Graphene oxide (GO) was incorporated into poly(lactic acid) (PLA) as a reinforcing nanofiller to produce composite nanofibrous scaffolds using the electrospinning technique. To improve the dispersion of GO in PLA and the interfacial adhesion between the filler and matrix, GO was surface-grafted with poly(ethylene glycol) (PEG). Morphological, thermal, mechanical, and wettability properties, as well as preliminary cytocompatibility with Swiss mouse NIH 3T3 cells of PLA, PLA/GO, and PLA/GO-g-PEG electrospun nanofibers, were characterized. Results showed that the average diameter of PLA/GO-g-PEG electrospun nanofibers decreased with filler content. Both GO and GO-g-PEG improved the thermal stability of PLA, but GO-g-PEG was more effective. The water contact angle test of the nanofiber mats showed that the addition of GO in PLA did not change the surface wettability of the materials, but PLA/GO-g-PEG samples exhibited improved wettability with lower water contact angles. The tensile strength of the composite nanofiber mats was improved with the addition of GO, and it was further enhanced when GO was surface grafted with PEG. This suggested that improved interfacial adhesion between GO and PLA was achieved by grafting PEG onto the GO. The cell viability and proliferation results showed that the cytocompatibility of PLA was not compromised with the addition of GO and GO-g-PEG. With enhanced mechanical properties as well as good wettability and cytocompatibility, PLA/GO-g-PEG composite nanofibers have the potential to be used as scaffolds in tissue engineering.

126 citations


Journal ArticleDOI
TL;DR: The blends containing 25% TPU and 75% PCL possessed the best shape memory properties as indicated by a 98% shape fixing ratio and 90% shape recovery ratio and it was found that PCL and TPU had good miscibility and that the PCL domain in TPU25% had higher crystallinity than neat PCL.
Abstract: Thermally responsive shape memory polymers have promising applications in many fields, especially in biomedical areas. In this study, a simple method was purposed to prepare thermoplastic polyurethane (TPU)/poly(e-caprolactone) (PCL) blends that possess shape memory attributes. TPU and PCL were melt compounded via a twin-screw extruder and injection molded at various ratios. Multiple test methods were used to characterize their shape memory properties and reveal the underling mechanism. The blends containing 25% TPU and 75% PCL possessed the best shape memory properties as indicated by a 98% shape fixing ratio and 90% shape recovery ratio. This was attributed to the hybrid crystalline and amorphous regions of PCL and TPU. We also found that PCL and TPU had good miscibility and that the PCL domain in TPU25% had higher crystallinity than neat PCL. The crystalline region in TPU25% could deform and maintain its temporary shape when stretched, which contributed to its high shape fixing attribute, while the rubbery TPU region assisted in the recovery of the sample upon heating by releasing the deformation energy stored. Moreover, the TPU25% string prepared could knot itself in a hot water bath, indicating a potential for suture applications. Lastly, the 3T3 fibroblast cells cultured on the TPU/PCL blends showed high viability and active substrate-cell interactions.

122 citations


Journal ArticleDOI
TL;DR: The SLM process is a promising candidate for preparing tough removable partial denture frameworks, as long as the appropriate build direction is adopted, with high degree of anisotropy in fatigue performance associated with the build orientation.
Abstract: We aimed to investigate the fatigue strength of Co-Cr-Mo clasps for removable partial dentures prepared by selective laser melting (SLM). The Co-Cr-Mo alloy specimens for tensile tests (dumbbell specimens) and fatigue tests (clasp specimens) were prepared by SLM with varying angles between the building and longitudinal directions (i.e., 0° (TL0, FL0), 45° (TL45, FL45), and 90° (TL90, FL90)). The clasp specimens were subjected to cyclic deformations of 0.25mm and 0.50mm for 10(6) cycles. The SLM specimens showed no obvious mechanical anisotropy in tensile tests and exhibited significantly higher yield strength and ultimate tensile strength than the cast specimens under all conditions. In contrast, a high degree of anisotropy in fatigue performance associated with the build orientation was found. For specimens under the 0.50mm deflection, FL90 exhibited significantly longer fatigue life (205,418 cycles) than the cast specimens (112,770 cycles). In contrast, the fatigue lives of FL0 (28,484 cycles) and FL45 (43,465 cycles) were significantly shorter. The surface roughnesses of FL0 and FL45 were considerably higher than those of the cast specimens, whereas there were no significant differences between FL90 and the cast specimens. Electron backscatter diffraction (EBSD) analysis indicated the grains of FL0 showed preferential close to orientation of the γ phase along the normal direction to the fracture surface. In contrast, the FL45 and FL90 grains showed no significant preferential orientation. Fatigue strength may therefore be affected by a number of factors, including surface roughness and crystal orientation. The SLM process is a promising candidate for preparing tough removable partial denture frameworks, as long as the appropriate build direction is adopted.

Journal ArticleDOI
TL;DR: Monolithic zirconia showed higher optical, but lower mechanical properties than conventional zirConia, and within groups aged in chewing simulator, ZS showed significantly lower flexural strength than CZI.
Abstract: Objectives To test the mechanical and optical properties of monolithic zirconia in comparison to conventional zirconia. Materials and methods Specimens were prepared from: monolithic zirconia: Zenostar (ZS), DD Bio ZX 2 hochtransluzent (DD), Ceramill Zolid (CZ), InCoris TZI (IC) and a conventional zirconia Ceramill ZI (CZI). Contrast ratio ( N =75/ n =15) was measured according to ISO 2471:2008. Grain sizes ( N =75/ n =15) were investigated with scanning electron microscope. Four-point flexural strength ( N =225/ n =15/zirconia and aging regime) was measured initially, after aging in autoclave or chewing simulator (ISO 13356:2008). Two-body wear of polished and glazed/veneered specimens ( N =108/ n =12) was analyzed in a chewing simulator using human teeth as antagonists. Data were analyzed using 2-/1-way ANOVA with post-hoc Scheffe, Kruskal–Wallis-H, Mann–Whitney-U, Spearman–Rho, Weibull statistics and linear mixed models ( p Results The lowest contrast ratio values were found for ZS and IC and CZ. IC showed the largest grain size followed by DD and CZI. The smallest grain size was observed for ZS followed by CZ. There was no correlation between grain size and contrast ratio. The aging regime showed no impact on flexural strength. All non-aged and autoclave-aged specimens showed lower flexural strengths than the control group CZI. Within groups aged in chewing simulator, ZS showed significantly lower flexural strength than CZI. CZI showed higher material and antagonist wear than monolithic polished and glazed groups. Glazed specimens showed higher material and antagonist loss compared to polished ones. There was no correlation between roughness and wear. Conclusions Monolithic zirconia showed higher optical, but lower mechanical properties than conventional zirconia.

Journal ArticleDOI
TL;DR: A parametric finite element model is developed to assess the effects of layers penetration׳s effect on inter-layer adhesion, which is reflected on the mechanical properties of bone scaffolds and is able to predict the mechanical behavior of fabricated bone scaffold accurately.
Abstract: In recent years, thanks to additive manufacturing technology, researchers have gone towards the optimization of bone scaffolds for the bone reconstruction. Bone scaffolds should have appropriate biological as well as mechanical properties in order to play a decisive role in bone healing. Since the fabrication of scaffolds is time consuming and expensive, numerical methods are often utilized to simulate their mechanical properties in order to find a nearly optimum one. Finite element analysis is one of the most common numerical methods that is used in this regard. In this paper, a parametric finite element model is developed to assess the effects of layers penetration׳s effect on inter-layer adhesion, which is reflected on the mechanical properties of bone scaffolds. To be able to validate this model, some compression test specimens as well as bone scaffolds are fabricated with biocompatible and biodegradable poly lactic acid using fused deposition modeling. All these specimens are tested in compression and their elastic modulus is obtained. Using the material parameters of the compression test specimens, the finite element analysis of the bone scaffold is performed. The obtained elastic modulus is compared with experiment indicating a good agreement. Accordingly, the proposed finite element model is able to predict the mechanical behavior of fabricated bone scaffolds accurately. In addition, the effect of post-heating of bone scaffolds on their elastic modulus is investigated. The results demonstrate that the numerically predicted elastic modulus of scaffold is closer to experimental outcomes in comparison with as-built samples.

Journal ArticleDOI
TL;DR: The newly developed method, DIC combined with OCT imaging, is a powerful, fast and non-invasive methodology to study structural skin changes in real time and the tissue response provoked by mechanical loading or stretching.
Abstract: Stratum corneum and epidermal layers change in terms of thickness and roughness with gender, age and anatomical site. Knowledge of the mechanical and tribological properties of skin associated with these structural changes are needed to aid in the design of exoskeletons, prostheses, orthotics, body mounted sensors used for kinematics measurements and in optimum use of wearable on-body devices. In this case study, optical coherence tomography (OCT) and digital image correlation (DIC) were combined to determine skin surface strain and sub-surface deformation behaviour of the volar forearm due to natural tissue stretching. The thickness of the epidermis together with geometry changes of the dermal-epidermal junction boundary were calculated during change in the arm angle, from flexion (90°) to full extension (180°). This posture change caused an increase in skin surface Lagrange strain, typically by 25% which induced considerable morphological changes in the upper skin layers evidenced by reduction of epidermal layer thickness (20%), flattening of the dermal-epidermal junction undulation (45-50% reduction of flatness being expressed as Ra and Rz roughness profile height change) and reduction of skin surface roughness Ra and Rz (40-50%). The newly developed method, DIC combined with OCT imaging, is a powerful, fast and non-invasive methodology to study structural skin changes in real time and the tissue response provoked by mechanical loading or stretching.

Journal ArticleDOI
TL;DR: It is shown that disruption of microtubule dynamics affects cancer cell elasticity, suggesting therapeutic drugs targeting microtubules be monitored for significant elastic changes.
Abstract: The cytoskeleton is primarily responsible for providing structural support, localization and transport of organelles, and intracellular trafficking. The structural support is supplied by actin filaments, microtubules, and intermediate filaments, which contribute to overall cell elasticity to varying degrees. We evaluate cell elasticity in five different cell types with drug-induced cytoskeletal derangements to probe how actin filaments and microtubules contribute to cell elasticity and whether it is conserved across cell type. Specifically, we measure elastic stiffness in primary chondrocytes, fibroblasts, endothelial cells (HUVEC), hepatocellular carcinoma cells (HUH-7), and fibrosarcoma cells (HT 1080) subjected to two cytoskeletal destabilizers: cytochalasin D and nocodazole, which disrupt actin and microtubule polymerization, respectively. Elastic stiffness is measured by atomic force microscopy (AFM) and the disruption of the cytoskeleton is confirmed using fluorescence microscopy. The two cancer cell lines showed significantly reduced elastic moduli values (~0.5kPa) when compared to the three healthy cell lines (~2kPa). Non-cancer cells whose actin filaments were disrupted using cytochalasin D showed a decrease of 60-80% in moduli values compared to untreated cells of the same origin, whereas the nocodazole-treated cells showed no change in elasticity. Overall, we demonstrate actin filaments contribute more to elastic stiffness than microtubules but this result is cell type dependent. Cancer cells behaved differently, exhibiting increased stiffness as well as stiffness variability when subjected to nocodazole. We show that disruption of microtubule dynamics affects cancer cell elasticity, suggesting therapeutic drugs targeting microtubules be monitored for significant elastic changes.

Journal ArticleDOI
TL;DR: The scaffolds supported osteogenic differentiation of mesenchymal cells and interestingly, the stiffest IBOA-based scaffolds that were plasma treated with acrylic acid promoted osteogenesis more strongly than the other scaffolds.
Abstract: Polymerised High Internal Phase Emulsions (PolyHIPEs) are manufactured via emulsion templating and exhibit a highly interconnected microporosity. These materials are commonly used as thin membranes for 3D cell culture. This study uses emulsion templating in combination with microstereolithography to fabricate PolyHIPE scaffolds with a tightly controlled and reproducible architecture. This combination of methods produces hierarchical structures, where the microstructural properties can be independently controlled from the scaffold macrostructure. PolyHIPEs were fabricated with varying ratios of two acrylate monomers (2-ethylhexyl acrylate (EHA) and isobornyl acrylate (IBOA)) and varying nominal porosity to tune mechanical properties. Young's modulus, ultimate tensile stress (UTS) and elongation at failure were determined for twenty EHA/IBOA compositions. Moduli ranged from 63.01±9.13 to 0.36±0.04MPa, UTS from 2.03±0.33 to 0.11±0.01MPa and failure strain from 21.86±2.87% to 2.60±0.61%. Selected compositions were fabricated into macro-porous woodpile structures, plasma treated with air or acrylic acid and seeded with human embryonic stem-cell derived mesenchymal progenitor cells (hES-MPs). Confocal and two-photon microscopy confirmed cell proliferation and penetration into the micro- and macro-porous architecture. The scaffolds supported osteogenic differentiation of mesenchymal cells and interestingly, the stiffest IBOA-based scaffolds that were plasma treated with acrylic acid promoted osteogenesis more strongly than the other scaffolds.

Journal ArticleDOI
TL;DR: The rheological, mechanical and mucoadhesive properties of the polymeric blends can be manipulated by changing the concentrations of thepolymers and they suggest the blends are worthy of biomedical applications.
Abstract: The development of binary polymeric mixtures (polymer blends) containing bioadhesive and thermoresponsive polymers can provide new materials for biomedical applications, with higher contact, increased adhesion, prolonged residence time, protection, and in determined cases, secured absorption of an active agent from the site of application. Mixtures were prepared using a wide range of poloxamer 407 and Carbopol 971P(®) amounts. The rheological (flow and oscillatory), sol-gel transition temperature, mechanical (hardness, compressibility, adhesiveness, cohesiveness and elasticity), softness, and mucoadhesive properties of formulations were investigated. Moreover, the interaction between the different proportions of polymers was also analyzed. Continuous shear and oscillatory rheometry identified the plastic flow with various degrees of thixotropy, besides the viscoelastic behavior of formulations. The determination of gelation temperature displayed values ranged from 27.17 to 41.09°C. It was also found that low carbomer concentrations were enough to provide positive interaction parameter. However, the highest values were obtained for the polymeric blends with higher concentration of poloxamer 407. The mucoadhesion and softness index were greater in preparations containing 20% (w/w) poloxamer 407. The rheological, mechanical and mucoadhesive properties of the polymeric blends can be manipulated by changing the concentrations of the polymers and they suggest the blends are worthy of biomedical applications.

Journal ArticleDOI
TL;DR: Mechanical properties of ZC were substantially superior to the two other tested ceramics, but the scattering of data was the least in PIC, and the fatigue limit was found to be approximately half of the mean flexural strength for all tested ceramic.
Abstract: Purpose The aim of this study was to measure the mechanical properties and fatigue behavior of three contemporary used dental ceramics, zirconia Cercon® (ZC), lithium disilicate e.max® CAD (LD), and polymer-infiltrated ceramic Enamic® (PIC). Methods Flexural strength of each CAD/CAM ceramic was measured by three point bending (n=15) followed by Weibull analysis. Elastic modulus was calculated from the load–displacement curve. For cyclic fatigue loading, sinusoidal loading with a frequency of 8 Hz with minimum load 3 N were applied to these ceramics (n=24) using three point bending from 103 to 106 cycles. Fatigue limits of these ceramics were predicted with S–N fatigue diagram. Fracture toughness and Vickers hardness of the ceramics were measured respectively by single edge V-notch beam (SEVNB) and microindentation (Hv 0.2) methods. Chemical compositions of the materials׳ surfaces were analyzed by EDS, and microstructural analysis was conducted on the fracture surfaces by SEM. One-way ANOVA was performed and the level of significance was set at 0.05 to analyze the numerical results. Results The mean flexural strength of ZC, LD, and PIC was respectively 886.9, 356.7, and 135.8 MPa. However, the highest Weibull modulus belonged to PIC with 19.7 and the lowest was found in LD with 7.0. The fatigue limit of maximum load for one million cycles of ZC, LD, and PIC was estimated to be 500.1, 168.4, and 73.8 GPa. The mean fracture toughness of ZC, LD, and PIC was found to be respectively 6.6, 2.8, and 1.4 MPa m1/2, while the mean Vickers hardness was 1641.7, 676.7, and 261.7 Hv. Fracture surfaces followed fatigue loading appeared to be smoother than that after monotonic loading. Conclusions Mechanical properties of ZC were substantially superior to the two other tested ceramics, but the scattering of data was the least in PIC. The fatigue limit was found to be approximately half of the mean flexural strength for all tested ceramics.

Journal ArticleDOI
TL;DR: In low-density bone, endosteal implants present higher insertion torque levels when placed in osseodensification drilling sites, with no osseointegration impairment compared to standard subtractive drilling methods.
Abstract: A bone drilling concept, namely osseodensification, has been introduced for the placement of endosteal implants to increase primary stability through densification of the osteotomy walls. This study investigated the effect of osseodensification on the initial stability and early osseointegration of conical and parallel walled endosteal implants in low density bone. Five male sheep were used. Three implants were inserted in the ilium, bilaterally, totaling 30 implants (n=15 conical, and n=15 parallel). Each animal received 3 implants of each type, inserted into bone sites prepared as follows: (i) regular-drilling (R: 2mm pilot, 3.2mm, and 3.8mm twist drills), (ii) clockwise osseodensification (CW), and (iii) counterclockwise (CCW) osseodensification drilling with Densah Bur (Versah, Jackson, MI, USA): 2.0mm pilot, 2.8mm, and 3.8mm multi-fluted burs. Insertion torque as a function of implant type and drilling technique, revealed higher values for osseodensification relative to R-drilling, regardless of implant macrogeometry. A significantly higher bone-to-implant contact (BIC) for both osseodensification techniques (p<0.05) was observed compared to R-drilling. There was no statistical difference in BIC as a function of implant type (p=0.58), nor in bone-area-fraction occupancy (BAFO) as a function of drilling technique (p=0.22), but there were higher levels of BAFO for parallel than conic implants (p=0.001). Six weeks after surgery, new bone formation along with remodeling sites was observed for all groups. Bone chips in proximity with the implants were seldom observed in the R-drilling group, but commonly observed in the CW, and more frequently under the CCW osseodensification technique. In low-density bone, endosteal implants present higher insertion torque levels when placed in osseodensification drilling sites, with no osseointegration impairment compared to standard subtractive drilling methods.

Journal ArticleDOI
TL;DR: The presented preparation method permitted to prepare three-layered scaffolds with high control of porosity and pore size distribution and mechanical behaviors were found to be strongly affected by pore architecture of tested devices as well as the permeation of osteoblast and fibroblast in-vitro.
Abstract: Interface tissue engineering (ITE) is used to repair or regenerate interface living tissue such as for instance bone and cartilage. This kind of tissues present natural different properties from a biological and mechanical point of view. With the aim to imitating the natural gradient occurring in the bone-cartilage tissue, several technologies and methods have been proposed over recent years in order to develop polymeric functionally graded scaffolds (FGS). In this study three-layered scaffolds with a pore size gradient were developed by melt mixing polylactic acid (PLA) and two water-soluble porogen agents: sodium chloride (NaCl) and polyethylene glycol (PEG). Pore dimensions were controlled by NaCl granulometry while PEG solvation created a micropores network within the devices. Scaffolds were characterized from a morphological and mechanical point of view in order to find a correlation between the preparation method, the pore architecture and compressive mechanical behavior. Biological tests were also performed in order to study the effect of pore size gradient on the permeation of different cell lines in co-culture. To imitate the physiological work condition, compressive tests were also performed in phosphate buffered saline (PBS) solution at 37°C. The presented preparation method permitted to prepare three-layered scaffolds with high control of porosity and pore size distribution. Furthermore mechanical behaviors were found to be strongly affected by pore architecture of tested devices as well as the permeation of osteoblast and fibroblast in-vitro.

Journal ArticleDOI
TL;DR: Results showed an intricate network of ε-Co (hcp) lamellae in the γ- Co (fcc) matrix responsible of the high UTS and hardness values in the as-sintered state and a strong reduction in ductility after post-production thermal treatments.
Abstract: Direct Metal Laser Sintering (DMLS) technology based on a layer by layer production process was used to produce a Co-Cr-Mo-W alloy specifically developed for biomedical applications. The alloy mechanical response and microstructure were investigated in the as-sintered state and after post-production thermal treatments. Roughness and hardness measurements, and tensile and flexural tests were performed to study the mechanical response of the alloy while X-ray diffraction (XRD), electron microscopy (SEM, TEM, STEM) techniques and microanalysis (EDX) were used to investigate the microstructure in different conditions. Results showed an intricate network of e-Co (hcp) lamellae in the γ-Co (fcc) matrix responsible of the high UTS and hardness values in the as-sintered state. Thermal treatments increase volume fraction of the e-Co (hcp) martensite but slightly modify the average size of the lamellar structure. Nevertheless, thermal treatments are capable of producing a sensible increase in UTS and hardness and a strong reduction in ductility. These latter effects were mainly attributed to the massive precipitation of an hcp Co3(Mo,W)2Si phase and the contemporary formation of Si-rich inclusions.

Journal ArticleDOI
TL;DR: It is suggested that a proper solution treatment is an efficient strategy for improving the mechanical properties and corrosion resistance of As-SLM CoCrW alloy that show acceptable tensile ductility.
Abstract: In the study, the microstructure, mechanical property and metal release behavior of selective laser melted CoCrW alloys under different solution treatment conditions were systemically investigated to assess their potential use in orthopedic implants. The effects of the solution treatment on the microstructure, mechanical properties and metal release were systematically studied by OM, SEM, XRD, tensile test, and ICP-AES, respectively. The XRD indicated that during the solution treatment the alloy underwent the transformation of γ-fcc to e-hcp phase; the e-hcp phase nearly dominated in the alloy when treated at 1200°C following the water quenching; the results from OM, SEM showed that the microstructural change was occurred under different solution treatments; solution at 1150°C with furnace cooling contributed to the formation of larger precipitates at the grain boundary regions, while the size and number of the precipitates was decreased as heated above 1100°C with the water quenching; moreover, the diamond-like structure was invisible at higher solution temperature over 1150°C following water quenching; compared with the furnace cooling, the alloy quenched by water showed excellent mechanical properties and low amount of metal release; as the alloy heated at 1200°C, the mechanical properties of the alloy reached their optimum combination at UTS=1113.6MPa, 0.2%YS=639.5MPa, and E%=20.1%, whilst showed the lower total quantity of metal release. It is suggested that a proper solution treatment is an efficient strategy for improving the mechanical properties and corrosion resistance of As-SLM CoCrW alloy that show acceptable tensile ductility.

Journal ArticleDOI
TL;DR: This paper focuses on the effect of Nb and/or Zr micro-additions on the elastic modulus/yield strength balance and discusses microstructure, and the mechanical and electrochemical behaviour of four new β-Ti-8Mo-xNb-xZr (x=2-5) alloys, using tensile tests, X-ray diffraction, SEM characterisation, ultrasound technique and potentiodynamic polarisation methods.
Abstract: The development and characterisation of new metallic biomaterials that contain non-toxic and non-allergic elements but possess low elastic modulus and low biodegradation rates, has become a topic of serious investigation in orthopaedic implant application. The lowering of elastic modulus and improving of corrosion resistance can be achieved by specific chemical alloying and super-elasticity effects, associated with a stress-induced phase transformation from the BCC metastable beta phase to the orthorhombic α″ martensite. Using this framework, this paper focuses on the effect of Nb and/or Zr micro-additions on the elastic modulus/yield strength balance and discusses microstructure, and the mechanical and electrochemical behaviour of four new β-Ti-8Mo-xNb-xZr (x=2-5) alloys, using tensile tests, X-ray diffraction, SEM characterisation, ultrasound technique and potentiodynamic polarisation methods. The results reveal that the alloys exhibit a pronounced microstructural sensitivity response, with alloying elements and excellent agreement between β-stability and high mechanical strength, with increasing Nb additions. Although all the alloys possess excellent corrosion resistance and low Young׳s modulus, Ti-8Mo-4Nb-2Zr alloy, which consists of β+α'' phases, exhibits a low Young modulus of 35GPa, which is lower than those of the commercial alloys already used in biomedical implantation. The significant corrosion resistance, nontoxicity and better mechanical compatibility are properties pertinent to preventing stress shielding and bone resorption in orthopaedic implant applications.

Journal ArticleDOI
TL;DR: This paper presents an entirely new approach to computing the wall tension within an AAA that relies on trivial linear elastic finite element computations, which can be performed instantaneously in the clinical environment on the simplest computing hardware.
Abstract: Abdominal aortic aneurysm (AAA) is a permanent and irreversible dilation of the lower region of the aorta. It is a symptomless condition that if left untreated can expand to the point of rupture. Mechanically-speaking, rupture of an artery occurs when the local wall stress exceeds the local wall strength. It is therefore desirable to be able to non-invasively estimate the AAA wall stress for a given patient, quickly and reliably. In this paper we present an entirely new approach to computing the wall tension (i.e. the stress resultant equal to the integral of the stresses tangent to the wall over the wall thickness) within an AAA that relies on trivial linear elastic finite element computations, which can be performed instantaneously in the clinical environment on the simplest computing hardware. As an input to our calculations we only use information readily available in the clinic: the shape of the aneurysm in-vivo, as seen on a computed tomography (CT) scan, and blood pressure. We demonstrate that tension fields computed with the proposed approach agree well with those obtained using very sophisticated, state-of-the-art non-linear inverse procedures. Using magnetic resonance (MR) images of the same patient, we can approximately measure the local wall thickness and calculate the local wall stress. What is truly exciting about this simple approach is that one does not need any information on material parameters; this supports the development and use of patient-specific modelling (PSM), where uncertainty in material data is recognised as a key limitation. The methods demonstrated in this paper are applicable to other areas of biomechanics where the loads and loaded geometry of the system are known.

Journal ArticleDOI
TL;DR: The results of the study suggest that aligned nanofiber bundles may be useful for ligament and tendon tissue engineering based on their mechanical properties and ability to support cell adhesion, proliferation, and elongation.
Abstract: Electrospun nanofibers are a promising material for ligamentous tissue engineering, however weak mechanical properties of fibers to date have limited their clinical usage. The goal of this work was to modify electrospun nanofibers to create a robust structure that mimics the complex hierarchy of native tendons and ligaments. The scaffolds that were fabricated in this study consisted of either random or aligned nanofibers in flat sheets or rolled nanofiber bundles that mimic the size scale of fascicle units in primarily tensile load bearing soft musculoskeletal tissues. Altering nanofiber orientation and geometry significantly affected mechanical properties; most notably aligned nanofiber sheets had the greatest modulus; 125% higher than that of random nanofiber sheets; and 45% higher than aligned nanofiber bundles. Modifying aligned nanofiber sheets to form aligned nanofiber bundles also resulted in approximately 107% higher yield stresses and 140% higher yield strains. The mechanical properties of aligned nanofiber bundles were in the range of the mechanical properties of the native ACL: modulus=158±32MPa, yield stress=57±23MPa and yield strain=0.38±0.08. Adipose derived stem cells cultured on all surfaces remained viable and proliferated extensively over a 7 day culture period and cells elongated on nanofiber bundles. The results of the study suggest that aligned nanofiber bundles may be useful for ligament and tendon tissue engineering based on their mechanical properties and ability to support cell adhesion, proliferation, and elongation.

Journal ArticleDOI
TL;DR: The results identify the limits by which isotropic hyperelastic material models may be used to describe cartilage contact variables, indicating that the mechanical properties of cartilage for large strains change with tissue damage.
Abstract: Isotropic hyperelastic models have been used to determine the material properties of normal human cartilage, but there remains an incomplete understanding of how these properties may be altered by osteoarthritis. The aims of this study were to (1) measure the material constants of normal and osteoarthritic human knee cartilage using isotropic hyperelastic models; (2) determine whether the material constants correlate with histological measures of structure and/or cartilage tissue damage; and (3) quantify the abilities of two common isotropic hyperelastic material models, the neo-Hookean and Yeoh models, to describe articular cartilage contact force, area, and pressure. Small osteochondral specimens of normal and osteoarthritic condition were retrieved from human cadaveric knees and from the knees of patients undergoing total knee arthroplasty and tested in unconfined compression at loading rates and large strains representative of weight-bearing activity. Articular surface contact area and lateral deformation were measured concurrently and specimen-specific finite element models then were used to determine the hyperelastic material constants. Structural parameters were measured using histological techniques while the severity of cartilage damage was quantified using the OARSI grading scale. The hyperelastic material constants correlated significantly with OARSI grade, indicating that the mechanical properties of cartilage for large strains change with tissue damage. The measurements of contact area described anisotropy of the tissue constituting the superficial zone. The Yeoh model described contact force and pressure more accurately than the neo-Hookean model, whereas both models under-predicted contact area and poorly described the anisotropy of cartilage within the superficial zone. These results identify the limits by which isotropic hyperelastic material models may be used to describe cartilage contact variables. This study provides novel data for the mechanical properties of normal and osteoarthritic human articular cartilage and enhances our ability to model this tissue using simple isotropic hyperelastic materials.

Journal ArticleDOI
TL;DR: In this paper, the effectiveness of grain refinement through deformation is explored as a tool to modify the strength of Mg-3wt% Zn alloy in orthopaedic application.
Abstract: Magnesium is presently attracting a lot of interest as a replacement to clinically used orthopaedic implant materials, due to its ability to solve the stress shielding problems, biodegradability and osteocompatibility. However, the strength of Mg is still lower than the requirement and it becomes worse after it starts degrading fast, while being exposed in living body environment. This research explores the effectiveness of 'grain refinement through deformation', as a tool to modify the strength (while keeping elastic modulus unaffected) of Mg based alloys in orthopaedic application. Hot rolled Mg-3wt% Zn alloy (MZ3) has been investigated for its potential in orthopaedic implant. Microstructure, mechanical properties, bio-corrosion properties and biocompatibility of the rolled samples are probed into. Grain size gets refined significantly with increasing amount of deformation. The alloy experiences a marked improvement in hardness, yield strength, ultimate tensile strength, strain and toughness with finer grain size. An increment in accelerated corrosion rate is noted with decreasing grain size, which is correlated to the increased grain boundary area and mechano-chemical dissolution. However, immersion test in simulated body fluid (SBF) reveals reduction in corrosion rate after third day of immersion. This was possible owing to precipitation of protective hydroxyapatite (HA) layer, formed out of the interaction of SBF and the alloy. More nucleation sites at the grain boundary for fine grained samples help in forming more HA and thus reduce the corrosion rate. Human osteosarcoma cells show less viability and adhesion on grain refined alloy.

Journal ArticleDOI
TL;DR: The occlusal thickness of CAD-CAM monolithic zirconia crowns did not influence either the fracture resistance and the mode of failure of the restorations; the occlused thickness can be reduced up to a lower bound of 0.5mm keeping a sufficient strength to withstand Occlusal loads.
Abstract: Objectives: To compare the fracture resistance and mode of failure of CAD-CAM monolithic zirconia crowns with different occlusal thickness. Material and methods: Forty CAD-CAM monolithic zirconia crowns with different occlusal thickness were randomly distributed into 4 experimental groups: 2.0 mm (group 1), 1.5 mm (group 2), 1.0 mm (group 3) and 0.5 mm (group 4). The restorations were cemented onto human molars with a self-adhesive resin cement. The specimens were loaded until fracture; the fracture resistance and mode of failure were recorded. The data were statistically analyzed with the one-way ANOVA followed by the Fisher's Exact test with Bonferroni's correction (p=0.05). Results: The fracture resistance values of all the specimens exceeded the maximum physiological occlusal loads in molar regions. All the crowns showed cohesive microcracks of the zirconia core; only 1 crown with a thickness of 0.5 mm was interested by a complete fracture. Conclusions: The occlusal thickness of CAD-CAM monolithic zirconia crowns did not influence either the fracture resistance and the mode of failure of the restorations; the occlusal thickness of CAD-CAM monolithic zirconia crowns can be reduced up to a lower bound of 0.5 mm keeping a sufficient strength to withstand occlusal loads; CAD-CAM monolithic zirconia crowns showed sufficient fracture resistance to be used in molar regions, even in a thin configuration (0.5 mm).

Journal ArticleDOI
TL;DR: This paper derived analytical relationships that relate the micro-architecture of porous biomaterials made from a relatively unexplored unit cell, namely rhombicuboctahedron, to their elastic modulus, Poisson's ratio, and yield stress, and found that analytical solutions and numerical results show a very good agreement particularly for smaller values of apparent density.
Abstract: Thanks to recent developments in additive manufacturing techniques, it is now possible to fabricate porous biomaterials with arbitrarily complex micro-architectures Micro-architectures of such biomaterials determine their physical and biological properties, meaning that one could potentially improve the performance of such biomaterials through rational design of micro-architecture The relationship between the micro-architecture of porous biomaterials and their physical and biological properties has therefore received increasing attention recently In this paper, we studied the mechanical properties of porous biomaterials made from a relatively unexplored unit cell, namely rhombicuboctahedron We derived analytical relationships that relate the micro-architecture of such porous biomaterials, ie the dimensions of the rhombicuboctahedron unit cell, to their elastic modulus, Poisson's ratio, and yield stress Finite element models were also developed to validate the analytical solutions Analytical and numerical results were compared with experimental data from one of our recent studies It was found that analytical solutions and numerical results show a very good agreement particularly for smaller values of apparent density The elastic moduli predicted by analytical and numerical models were in very good agreement with experimental observations too While in excellent agreement with each other, analytical and numerical models somewhat over-predicted the yield stress of the porous structures as compared to experimental data As the ratio of the vertical struts to the inclined struts, α, approaches zero and infinity, the rhombicuboctahedron unit cell respectively approaches the octahedron (or truncated cube) and cube unit cells For those limits, the analytical solutions presented here were found to approach the analytic solutions obtained for the octahedron, truncated cube, and cube unit cells, meaning that the presented solutions are generalizations of the analytical solutions obtained for several other types of porous biomaterials

Journal ArticleDOI
TL;DR: The results showed that the water sorption for nHAP fillers reinforced resins was significantly lower than unfilled resins and the surface hardness for resins reinforced with silane treated fillers was superior to unfilled and untreated fillers resins.
Abstract: To evaluate the physical and mechanical properties of an experimental bis-GMA-based resin composite incorporated with non-silanized and silanized nano-hydroxyapatite (nHAP) fillers. Experimental bis-GMA based resin composites samples which were reinforced with nHAP fillers were prepared. Filler particles were surface treated with a silane coupling agent. Five test groups were prepared: 1. Unfilled, 2. Reinforced with 10wt% and 30wt% non-silanized nHAP fillers, and 3. Reinforced with 10wt% and 30wt% silanized nHAP fillers. The samples were subjected to tests in dry condition and in deionized water, aged at 37°C for 30 days. Prepared silanized and non-silanized nHAP were analyzed with Fourier Transform Infrared (FTIR) Spectroscopy and X-ray Photoelectron Spectroscopy (XPS). The micro-hardness and water sorption were evaluated. Data were analyzed by one-way ANOVA (p<0.05). The samples were characterized by FTIR Spectroscopy, Thermogravimetric Analysis and Differential Scanning Calorimetry. The surface morphology of sample surfaces was examined by Scanning Electron Microscope (SEM). The results showed that the water sorption for nHAP fillers reinforced resins was significantly lower than unfilled resins. Surface hardness for resins reinforced with silane treated fillers was superior to unfilled and untreated fillers resins. The resin matrix loaded with 30wt% silanized-nHAP fillers would improve the physical and mechanical properties of a bis-GMA based resin.