scispace - formally typeset
Proceedings ArticleDOI

Decentralized control for parallel operation of distributed generation inverters using resistive output impedance

Reads0
Chats0
TLDR
In this paper, a novel wireless load sharing controller for islanding parallel inverters in an ac distributed system is proposed, where the resistive output impedance of the parallel-connected inverters is explored.
Abstract
In this paper, a novel wireless load-sharing controller for islanding parallel inverters in an ac distributed system is proposed. The paper explorers the resistive output impedance of the parallel-connected inverters in an island microgrid

read more

Citations
More filters
Proceedings ArticleDOI

Planned communities as microgrid applications

TL;DR: In this article, the authors propose a business model for the application of the microgrid control architectures and philosophies, and link the core characteristics of the planned communities (PC) to existing MG sites and installations, providing evidence of their suitability for MG development.
Proceedings ArticleDOI

Hierarchical controlled grid-connected microgrid based on a novel autonomous current sharing controller

TL;DR: In this paper, a hierarchical control system based on a novel autonomous current sharing controller for grid-connected microgrids (MGs) is presented to guarantee the power sharing performance among voltage controlled parallel inverters.
Proceedings ArticleDOI

Research on the synchronization control strategy for microgrid-connected voltage source inverter

TL;DR: A novel synchronization method based on droop control is proposed that can smooth transfer the MVSI units from standalone mode to paralleled mode and show that the proposed method is effective in achieving paralleled operation of the MV SI units.
Proceedings ArticleDOI

Design considerations for microgrids with energy storage

TL;DR: In this article, the authors discuss the need for power quality microgrids to provide 1/4 cycle response to compete with existing power quality products by offering similar performance, but the challenge of force commutating the static switch is difficult.
Proceedings ArticleDOI

Enhanced power calculator for droop control in single-phase systems

TL;DR: In this article, a method that uses a fictitious quadrature reference frame to calculate the average power components is presented, which improves the dynamic response of the power sharing control and eliminates the double-frequency oscillation over the voltage and frequency synthesized by the inverter.
References
More filters
Journal ArticleDOI

Control of parallel connected inverters in stand-alone AC supply systems

TL;DR: In this article, a control scheme for parallel-connected inverters in a standalone AC supply system is presented, which uses feedback of only those variables that can be measured locally at the inverter and does not need communication of control signals between the inverters.
Journal ArticleDOI

Output impedance design of parallel-connected UPS inverters with wireless load-sharing control

TL;DR: This paper deals with the design of the output impedance of uninterruptible power system (UPS) inverters with parallel-connection capability, and proposes novel control loops to achieve both stable output impedance and proper power balance.
Journal ArticleDOI

A wireless controller to enhance dynamic performance of parallel inverters in distributed generation systems

TL;DR: In this paper, a novel control strategy for parallel inverters of distributed generation units in an AC distribution system is presented, based on the droop control method, using only locally measurable feedback signals.
Book

Power Systems Analysis

TL;DR: In this article, the authors present a model of a single machine-infinite bus (SIB) with three-phase transformer connections for the purpose of detecting faults in a generator.
Journal ArticleDOI

Wireless-Control Strategy for Parallel Operation of Distributed-Generation Inverters

TL;DR: Adapt virtual output impedance is proposed in order to achieve a proper reactive power sharing regardless of the line impedance unbalances and can be properly shared due to the addition of a current harmonic loop in the control strategy.
Related Papers (5)