scispace - formally typeset
Journal ArticleDOI

Self-adaptive transformer differential protection

TLDR
In this paper, a novel adaptive protection criterion is proposed, which can self-regulate the parameters of percentage differential characteristic (e.g., pickup current, restraint coefficient and restraint current at the knee point of the slope characteristic) on the basis of operating conditions of power transformers.
Abstract
Setting the pickup current and slope of differential relays of power transformer protection is a well-known compromise. It has been the focus of study to improve both the security and sensitivity of transformer differential protection recently. However, it is difficult to achieve a high degree of security and sensitivity at the same time by conventional percentage restraint differential criteria based on a fixed predetermined characteristic curve. Therefore a novel adaptive protection criterion is proposed in this study, which can self-regulate the parameters of percentage differential characteristic (e.g. pickup current, restraint coefficient and restraint current at the knee point of the slope characteristic) on the basis of operating conditions of power transformers. The test results show that the proposed scheme provides a high operating sensitivity on internal faults, while retaining higher security on all external faults. Furthermore, because of self-regulation of the setting values of relays, it is more convenient for engineers in the field who only need to give the upper and lower limits but not the exact value of the settings of protective relay.

read more

Citations
More filters
Journal ArticleDOI

Dynamic State Estimation-Based Protection: Status and Promise

TL;DR: A new approach to protection that promises to eliminate the majority of the problems that lead to misoperations is presented and demonstrated in the laboratory and its application to a substation coordinated protection system capable of detecting and dealing with hidden failures is described.
Journal ArticleDOI

Algorithm for transformer differential protection based on wavelet correlation modes

TL;DR: A new algorithm for discrimination between internal faults and inrush current conditions in power transformers is presented and is used to identify inrush and internal fault currents in power transformer.
Journal ArticleDOI

Power transformers monitoring based on electrical measurements: state of the art

TL;DR: In this article, the authors present a review of the most important techniques and a critical comparison between them and present new alternatives, such as frequency response analysis, an offline application technique.
Journal ArticleDOI

Histogram-Based Method to Avoid Maloperation of Transformer Differential Protection Due to Current-Transformer Saturation Under External Faults

TL;DR: In this paper, a histogram of the normalized rotated current (NRC) frequency distribution was proposed to detect external faults with different degrees of CT saturation, internal faults, and transferring faults.
Journal ArticleDOI

New approach to improve sensitivity of differential and restricted earth fault protections for industrial transformers

TL;DR: In this paper, an effective approach is proposed to improve the differential and restricted earth fault (this paper) protections sensitivity of industrial transformers, which not only realises the fault current limitation function, but preserves sensitivity of the protections.
References
More filters
Journal ArticleDOI

Analysis of a Sort of Unusual Mal-Operation of Transformer Differential Protection Due to Removal of External Fault

TL;DR: In this article, a mathematical model for analyzing the transient course of external fault inception and removal, together with the CT model involving the magnetic hysteresis effect, is proposed.
Journal ArticleDOI

A New Techniques of Differential Relaying the Differential Relay

TL;DR: In this paper, a new technique of differential protection is proposed which considers only fault contribution currents through the use of microcomputer cancellation of the prefault through currents, which is substantially more sensitive to high impedance faults than the standard arrangement.

The influlence and countermeasure to transformer differential protection of ct partial transient saturation caused by external fault removal

TL;DR: An inverses time current differential protection scheme based on detecting external faults removal and avoiding the maloperation of the different protection due to CT partial transient saturation during the removal of external fault is proposed.

Comparative studies on percentage differential criteria using phase currentand superimposed pahse current

TL;DR: In this paper, the sensitivity and the security of the percentage differential criteria using phase current and superimposed phase current are studied comparatively and it is confirmed that the superimposed based criterion is better than phase current based one in terms of sensitivity.
Journal Article

Selection of settings of differential protection based on fault component

Li Xiao
TL;DR: It is expounded that the differential protection based on fault component differs from conventional protective devices, the selection of settings for the latter should not indiscriminately imitate the former, and how to select the settings is discussed.