scispace - formally typeset
Open AccessJournal ArticleDOI

An experimental study of respiratory aerosol transport in phantom lung bronchioles.

Reads0
Chats0
TLDR
Lower breathing frequency and higher breath hold time could significantly increase the chances of getting infected with COVID-19 in crowded places.
Abstract
The transport and deposition of micrometer-sized particles in the lung is the primary mechanism for the spread of aerosol borne diseases such as corona virus disease-19 (COVID-19). Considering the current situation, modeling the transport and deposition of drops in human lung bronchioles is of utmost importance to determine their consequences on human health. The current study reports experimental observations on deposition in micro-capillaries, representing distal lung bronchioles, over a wide range of Re that imitates the particle dynamics in the entire lung. The experiment investigated deposition in tubes of diameter ranging from 0.3 mm to 2 mm and over a wide range of Reynolds number (10−2 ⩽ Re ⩽ 103). The range of the tube diameter and Re used in this study is motivated by the dimensions of lung airways and typical breathing flow rates. The aerosol fluid was loaded with boron doped carbon quantum dots as fluorophores. An aerosol plume was generated from this mixture fluid using an ultrasonic nebulizer, producing droplets with 6.5 µm as a mean diameter and over a narrow distribution of sizes. The amount of aerosol deposited on the tube walls was measured using a spectrofluorometer. The experimental results show that dimensionless deposition (δ) varies inversely with the bronchiole aspect ratio ( L ¯ ), with the effect of the Reynolds number (Re) being significant only at low L ¯ . δ also increased with increasing dimensionless bronchiole diameter ( D ¯ ), but it is invariant with the particle size based Reynolds number. We show that δ L ¯ ∼ R e − 2 for 10−2 ⩽ Re ⩽ 1, which is typical of a diffusion dominated regime. For Re ⩾ 1, in the impaction dominated regime, δ L ¯ is shown to be independent of Re. We also show a crossover regime where sedimentation becomes important. The experimental results conclude that lower breathing frequency and higher breath hold time could significantly increase the chances of getting infected with COVID-19 in crowded places.

read more

Citations
More filters
Journal ArticleDOI

SARS CoV-2 aerosol: How far it can travel to the lower airways?

TL;DR: In this article, the authors investigated the SARS CoV-2 virus particle transport and deposition to the terminal airways in a complex 17-generation lung model and showed that a higher percentage of the virus particles are trapped at the upper airways when sleeping and in a light activity condition.
Journal ArticleDOI

Aerosol generation in public restrooms

TL;DR: In this article, the authors measured the size and number of droplets generated by flushing toilets and urinals in a public restroom and found that the particular designs tested in the study generate a large number of aerosol in the size range 0.3 μ m − 3 μ m, which can reach heights of at least 1.52 m.
Journal ArticleDOI

A dynamical overview of droplets in the transmission of respiratory infectious diseases.

TL;DR: In this article, the authors describe respiratory droplets from a physical and mechanical perspective, especially their correlation with the transmission of infectious pathogens, and stress the multidisciplinary nature of their subject and appeals for collaboration among different fields to fight the present pandemic.
Journal ArticleDOI

Designing antiviral surfaces to suppress the spread of COVID-19

TL;DR: In this paper, the authors explored the disjoining pressure-driven thin-film evaporation mechanism and thereby the virucidal properties of engineered surfaces with varied wettability and texture.
References
More filters
Journal ArticleDOI

Comparison of ambient and spray aerosol deposition in a standard induction port and more realistic mouth–throat geometry

TL;DR: In this article, the effect of spray momentum on deposition in a standard induction port and a representative mouth-throat (MT) geometry using capillary-generated aerosols was evaluated.
Journal ArticleDOI

Transport and fate of human expiratory droplets-A modeling approach.

TL;DR: A modeling approach to understand the fundamental dynamics of exhaled droplets in human respiratory activities is presented and it is shown that these droplets are sensitive to environmental conditions, including temperature, humidity, and ambient flows.
Journal ArticleDOI

Respiratory fluid mechanics

TL;DR: This article covers several aspects of respiratory fluid mechanics that have been actively investigated by this group over the years including liquid plug flow in airways and at airway bifurcations as it relates to surfactant, drug, gene, or stem cell delivery into the lung.
Journal ArticleDOI

Mathematical Analysis of Particle Deposition in Human Lungs: An Improved Single Path Transport Model

TL;DR: The present model provides an improvement from the previously reported models and can be used as a tool in assessing internal dose of inhaled particles under various inhalation conditions.
Journal ArticleDOI

Aerosol deposition in a pipe with turbulent airflow

TL;DR: In this paper, a wind tunnel was constructed to establish completely developed turbulent flow in a 6-in. pipe in which an aerosol was moving under turbulent flow conditions, and Reynolds Numbers were as high as 367,000.
Related Papers (5)