scispace - formally typeset
Journal ArticleDOI

High Reliability and Efficiency Single-Phase Transformerless Inverter for Grid-Connected Photovoltaic Systems

Reads0
Chats0
TLDR
In this article, a high-reliability single-phase transformerless grid-connected inverter that utilizes superjunction MOSFETs to achieve high efficiency for photovoltaic applications is presented.
Abstract
This paper presents a high-reliability single-phase transformerless grid-connected inverter that utilizes superjunction MOSFETs to achieve high efficiency for photovoltaic applications. The proposed converter utilizes two split ac-coupled inductors that operate separately for positive and negative half grid cycles. This eliminates the shoot-through issue that is encountered by traditional voltage source inverters, leading to enhanced system reliability. Dead time is not required at both the high-frequency pulsewidth modulation switching commutation and the grid zero-crossing instants, improving the quality of the output ac-current and increasing the converter efficiency. The split structure of the proposed inverter does not lead itself to the reverse-recovery issues for the main power switches and as such superjunction MOSFETs can be utilized without any reliability or efficiency penalties. Since MOSFETs are utilized in the proposed converter high efficiency can be achieved even at light load operations achieving a high California energy commission (CEC) or European union efficiency of the converter system. It also has the ability to operate at higher switching frequencies while maintaining high efficiency. The higher operating frequencies with high efficiency enables reduced cooling requirements and results in system cost savings by shrinking passive components. With two additional ac-side switches conducting the currents during the freewheeling phases, the photovoltaic array is decoupled from the grid. This reduces the high-frequency common-mode voltage leading to minimized ground loop leakage current. The operation principle, common-mode characteristic and design considerations of the proposed transformerless inverter are illustrated. The total losses of the power semiconductor devices of several existing transformerless inverters which utilize MOSFETs as main switches are evaluated and compared. The experimental results with a 5 kW prototype circuit show 99.0% CEC efficiency and 99.3% peak efficiency with a 20 kHz switching frequency. The high reliability and efficiency of the proposed converter makes it very attractive for single-phase transformerless photovoltaic inverter applications.

read more

Citations
More filters
Proceedings ArticleDOI

Bridgeless Three-Level Power Factor Correction Rectifier Using SiC MOSFETs with High Efficiency

TL;DR: The proposed rectifier minimizes the overall conduction losses by eliminating the full-bridge diode rectifier and by replacing the outer switches of T-type leg with SiC MOSFETs.
Proceedings ArticleDOI

A novel fuzzy based transformer less PV inverter for reactive power control in grid connected PV system

TL;DR: A newly proposed transformerless inverter for grid tied PV system can eliminate the threat of leakage current and has the ability to inject reactive power into the utility grid.
Journal ArticleDOI

Suppression of Common-Mode Voltage in a Multi-Central Large-Scale PV Generation Systems for Medium-Voltage Grid Connection

TL;DR: An optimal configuration for multi-central inverters in a medium-voltage (MV) grid, which is suitable for large-scale photovoltaic (PV) power plants, and proposes a synchronized PWM control strategy to effectively reduce the common-mode voltages that may simultaneously occur.
Patent

A novel bifurcation diagram drawing method suitable for a sliding mode variable structure control inverter

TL;DR: In this paper, a variable-sample point bifurcation diagram drawing method was proposed to determine systematic stability work regions accurately and can be used for analyzing bifurlcation behaviors of systems.
Book ChapterDOI

A New Control Strategy for Photovoltaic System Connected to the Grid via Three-Time-Scale Singular Perturbation Technique with Performance Analysis

TL;DR: This chapter addresses the problem of controlling single-phase grid-connected photovoltaic system through a full bridge inverter with L-filter using singular perturbation technique, in which a three-time-scale dynamics is artificially induced in the closed-loop system.
References
More filters
Journal ArticleDOI

A review of single-phase grid-connected inverters for photovoltaic modules

TL;DR: In this article, the authors focus on inverter technologies for connecting photovoltaic (PV) modules to a single-phase grid and categorize the inverters into four classifications: 1) the number of power processing stages in cascade; 2) the type of power decoupling between the PV module(s) and the single phase grid; 3) whether they utilizes a transformer (either line or high frequency) or not; and 4) the kind of grid-connected power stage.
Journal ArticleDOI

A Review of the Single Phase Photovoltaic Module Integrated Converter Topologies With Three Different DC Link Configurations

TL;DR: In this paper, a topology study of the PV MICs in the power range below 500 W and covers most topologies recently proposed for MIC applications is presented, where the MIC topologies are classified into three different arrangements based on the dc link configurations.
Journal ArticleDOI

Topologies of single-phase inverters for small distributed power generators: an overview

TL;DR: In this paper, an overview of single-phase inverters developed for small distributed power generators is presented, compared, and evaluated against the requirements of power decoupling and dual-grounding, the capabilities for grid-connected or/and stand-alone operations, and specific DG applications.
Journal ArticleDOI

A New High-Efficiency Single-Phase Transformerless PV Inverter Topology

TL;DR: This paper proposes a new topology, based on the H-bridge with a new ac bypass circuit consisting of a diode rectifier and a switch with clamping to the dc midpoint, which achieves high conversion efficiency and low leakage current.
Journal ArticleDOI

Transformerless Inverter for Single-Phase Photovoltaic Systems

TL;DR: In this article, the authors proposed a new high-efficiency topology that generates no varying common-mode voltage and requires the same low-input voltage as the bipolar PWM full bridge.
Related Papers (5)