scispace - formally typeset
Journal ArticleDOI

Micro-grid autonomous operation during and subsequent to islanding process

Reads0
Chats0
TLDR
In this paper, the authors investigated preplanned switching events and fault events that lead to islanding of a distribution subsystem and formation of a micro-grid, and they concluded that an appropriate control strategy for the power electronically interfaced DG unit can ensure stability of the microgrid and maintain voltage quality at designated buses, even during islanding transients.
Abstract
This paper investigates (i) preplanned switching events and (ii) fault events that lead to islanding of a distribution subsystem and formation of a micro-grid. The micro-grid includes two distributed generation (DG) units. One unit is a conventional rotating synchronous machine and the other is interfaced through a power electronic converter. The interface converter of the latter unit is equipped with independent real and reactive power control to minimize islanding transients and maintain both angle stability and voltage quality within the micro-grid. The studies are performed based on a digital computer simulation approach using the PSCAD/EMTDC software package. The studies show that an appropriate control strategy for the power electronically interfaced DG unit can ensure stability of the micro-grid and maintain voltage quality at designated buses, even during islanding transients. This paper concludes that presence of an electronically-interfaced DG unit makes the concept of micro-grid a technically viable option for further investigations.

read more

Citations
More filters
Journal ArticleDOI

Three Control Strategies to Improve the Microgrid Transient Dynamic Response During Isolated Mode: A Comparative Study

TL;DR: Three techniques are proposed for solving and reducing the consequences of wind speed fluctuations in microgrids, including a new fuzzy logic pitch angle controller and an energy-storage ultracapacitor which directly smoothes the output power of the wind turbine and enhances the performance of the MG during the islanding mode.
Journal ArticleDOI

Protection of Autonomous Microgrids using Agent-Based Distributed Communication

TL;DR: In this article, a real-time implementation of autonomous microgrid protection using agent-based distributed communication is presented, where a practical overcurrent and a frequency-selectivity method are introduced to overcome conventional limitations.
Journal ArticleDOI

Microgrid optimal scheduling with chance-constrained islanding capability

TL;DR: In this paper, a new concept, probability of successful islanding (PSI), indicating the probability that a microgrid maintains enough spinning reserve (both up and down) to meet local demand and accommodate local renewable generation after instantaneously islanding from the main grid, is developed.
Journal ArticleDOI

Review of microgrid architectures – a system of systems perspective

TL;DR: A review of microgrid architectures and models is presented in this article, where various control schemes devised for microgrids are also reviewed and the concept of SoSs is introduced and its applications are discussed.
Journal ArticleDOI

The Migrate project: the challenges of operating a transmission grid with only inverter-based generation. A grid-forming control improvement with transient current-limiting control

TL;DR: In this article, the authors proposed a solution to allow a stable operation of the system together with a limited solicitation of inverters during transients, in order to ensure the same level of reliability as today.
References
More filters
Book

Electrical Power Systems Quality

TL;DR: In this paper, the authors present a power quality evaluation procedure for the purpose of measuring the power quality of a power supply. But, they do not define the specific classes of power quality problems.

Vector analysis and control of advanced static VAr compensators

TL;DR: The advanced static VAr compensator (ASVC) as mentioned in this paper is based on the principle that a self-commutating static inverter can be connected between three-phase AC power lines and an energy storage device, such as an inductor or capacitor, and controlled to draw mainly reactive current from the lines.
Journal ArticleDOI

Vector analysis and control of advanced static VAr compensators

TL;DR: In this paper, two fundamentally different types of invertor can be used for this purpose, one providing control of output voltage magnitude and phase angle, and the other having only phase angle control.
Journal ArticleDOI

Protection against loss of utility grid supply for a dispersed storage and generation unit

TL;DR: In this paper, the requirements of an islanding, or "loss of grid", protection for a dispersed storage and generation unit are examined, and the principal methods used for this type of relaying are outlined.
Proceedings ArticleDOI

Distributed energy sources: technical challenges

TL;DR: In this article, the main related technical issues are discussed together with the DGs modelling requirements for their analysis, and the main technical issues of the micro-grid are discussed and discussed in detail.
Related Papers (5)