scispace - formally typeset
Journal ArticleDOI

Three-Dimensional Ultrasound Imaging

Reads0
Chats0
TLDR
A review article describes the developments of a number of 3D ultrasound imaging systems using mechanical, free-hand and 2D array scanning techniques and the sources of errors in the reconstruction techniques as well as formulae relating design specification to geometric errors.
Abstract
Ultrasound is an inexpensive and widely used imaging modality for the diagnosis and staging of a number of diseases. In the past two decades, it has benefited from major advances in technology and has become an indispensable imaging modality, due to its flexibility and non-invasive character. In the last decade, research investigators and commercial companies have further advanced ultrasound imaging with the development of 3D ultrasound. This new imaging approach is rapidly achieving widespread use with numerous applications. The major reason for the increase in the use of 3D ultrasound is related to the limitations of 2D viewing of 3D anatomy, using conventional ultrasound. This occurs because: (a) Conventional ultrasound images are 2D, yet the anatomy is 3D, hence the diagnostician must integrate multiple images in his mind. This practice is inefficient, and may lead to variability and incorrect diagnoses. (b) The 2D ultrasound image represents a thin plane at some arbitrary angle in the body. It is difficult to localize the image plane and reproduce it at a later time for follow-up studies. In this review article we describe how 3D ultrasound imaging overcomes these limitations. Specifically, we describe the developments of a number of 3D ultrasound imaging systems using mechanical, free-hand and 2D array scanning techniques. Reconstruction and viewing methods of the 3D images are described with specific examples. Since 3D ultrasound is used to quantify the volume of organs and pathology, the sources of errors in the reconstruction techniques as well as formulae relating design specification to geometric errors are provided. Finally, methods to measure organ volume from the 3D ultrasound images and sources of errors are described.

read more

Citations
More filters

Towards anImplantable Vestibular Prosthesis: TheSurgical Challenges

TL;DR: The challenges modernsurgical technology would encounter inopting a vestibular prosthesis are presented and possible solutions are proposed, aiming topromote andmotivate research in this direction.
Proceedings ArticleDOI

Fast and automatic array tilt compensation for 1.5D array transducers

TL;DR: In this article , a simplified method for exploiting the out-of-plane correction capabilities of a 1.5D array without the burden of complex imaging methods like Total Focusing Method (TFM), which inevitable increase the inspection time and the electronic system complexity.
Proceedings ArticleDOI

Clinical realization of short-lag spatial coherence imaging on 2D arrays

TL;DR: Volumetric SLSC imaging shows suppressed clutter and improved visualization of blood vessels when compared to conventional 3D B-mode when compared as well as better image quality in 3D ultrasound.
Proceedings ArticleDOI

3D reconstruction of human enamel Ex vivo using high frequency ultrasound

TL;DR: A new scanning system which collects structural information of tooth surface and enamel-dentine junction and the enamel in a 3D form will be reconstructed with this system.
Journal ArticleDOI

Complete region of interest reconstruction by fusing multiview deformable three-dimensional transesophageal echocardiography images.

TL;DR: A novel multiview non-rigid registration and fusion method to extend the FoV of 3D TEE images at different cardiac phases, avoiding the bias towards the specifically chosen phase.
References
More filters
Journal ArticleDOI

Deformable models in medical image analysis: a survey

TL;DR: The rapidly expanding body of work on the development and application of deformable models to problems of fundamental importance in medical image analysis, including segmentation, shape representation, matching and motion tracking is reviewed.
Journal ArticleDOI

Efficient ray tracing of volume data

TL;DR: This paper presents a front-to-back image-order volume-rendering algorithm and discusses two techniques for improving its performance, which employs a pyramid of binary volumes to encode spatial coherence present in the data and uses an opacity threshold to adaptively terminate ray tracing.
Journal ArticleDOI

Review of MR image segmentation techniques using pattern recognition.

TL;DR: This paper has reviewed, with somewhat variable coverage, the nine MR image segmentation techniques itemized in Table II; each has its merits and drawbacks.
Journal ArticleDOI

Magnetic Position and Orientation Tracking System

TL;DR: In this article, linear rotation transformations based upon the previous measurements are applied to both the source excitation and sensor output vectors, yielding quantities that are linearly propotional to small changes in the position and orientation.
Journal ArticleDOI

Multidimensional transfer functions for interactive volume rendering

TL;DR: An important class of 3D transfer functions for scalar data is demonstrated, and the application of multi-dimensional transfer functions to multivariate data is described, and a set of direct manipulation widgets that make specifying such transfer functions intuitive and convenient are presented.
Related Papers (5)