scispace - formally typeset
Journal ArticleDOI

Three-Dimensional Ultrasound Imaging

Reads0
Chats0
TLDR
A review article describes the developments of a number of 3D ultrasound imaging systems using mechanical, free-hand and 2D array scanning techniques and the sources of errors in the reconstruction techniques as well as formulae relating design specification to geometric errors.
Abstract
Ultrasound is an inexpensive and widely used imaging modality for the diagnosis and staging of a number of diseases. In the past two decades, it has benefited from major advances in technology and has become an indispensable imaging modality, due to its flexibility and non-invasive character. In the last decade, research investigators and commercial companies have further advanced ultrasound imaging with the development of 3D ultrasound. This new imaging approach is rapidly achieving widespread use with numerous applications. The major reason for the increase in the use of 3D ultrasound is related to the limitations of 2D viewing of 3D anatomy, using conventional ultrasound. This occurs because: (a) Conventional ultrasound images are 2D, yet the anatomy is 3D, hence the diagnostician must integrate multiple images in his mind. This practice is inefficient, and may lead to variability and incorrect diagnoses. (b) The 2D ultrasound image represents a thin plane at some arbitrary angle in the body. It is difficult to localize the image plane and reproduce it at a later time for follow-up studies. In this review article we describe how 3D ultrasound imaging overcomes these limitations. Specifically, we describe the developments of a number of 3D ultrasound imaging systems using mechanical, free-hand and 2D array scanning techniques. Reconstruction and viewing methods of the 3D images are described with specific examples. Since 3D ultrasound is used to quantify the volume of organs and pathology, the sources of errors in the reconstruction techniques as well as formulae relating design specification to geometric errors are provided. Finally, methods to measure organ volume from the 3D ultrasound images and sources of errors are described.

read more

Citations
More filters
Proceedings ArticleDOI

Direct 3D segmentation of carotid plaques from 3D ultrasound images

TL;DR: A direct 3D segmentation method is proposed to segment carotid plaques from 3D ultrasound images and suggests that the proposed 3D method outperforms the 2D slice-by-slice approach.
Journal Article

Cardiovascular ultrasound imaging – A survey of technical development

TL;DR: The physics fundamentals in cardiovascular imaging using ultrasound using ultrasound are reviewed and the current technology and advances in clinical practices are discussed.
Journal ArticleDOI

Actuator-Assisted Calibration of Freehand 3D Ultrasound System

TL;DR: It appears that both actuator-assisted cross wire phantom and modified collinear point target phantom calibration approaches are viable options for freehand 3D ultrasound calibration.
Journal ArticleDOI

Subject-specific and respiration-corrected 4D liver model from real-time ultrasound image sequences

TL;DR: It is concluded that the reconstructed 3D image sequence can capture the moving liver during a half respiratory cycle, and the proposed method is feasible to visualise the 3D liver motion.
Journal ArticleDOI

Author response to: Brough et al. in response to the recently published article: Lottering, N., MacGregor, D.M., Barry, M.D., Reynolds, M.S., Gregory, L.S., 2014. Introducing standardized protocols for anthropological measurement of virtual sub-adult crania using computed tomography 2(1), 34–38

TL;DR: It is affirm that the use of geometrically based reference tools commonly found in computer aided design (CAD) programs such as Geomagic Design X® are imperative for more automated and precise measurement protocols for quantitative skeletal analysis.
References
More filters
Journal ArticleDOI

Deformable models in medical image analysis: a survey

TL;DR: The rapidly expanding body of work on the development and application of deformable models to problems of fundamental importance in medical image analysis, including segmentation, shape representation, matching and motion tracking is reviewed.
Journal ArticleDOI

Efficient ray tracing of volume data

TL;DR: This paper presents a front-to-back image-order volume-rendering algorithm and discusses two techniques for improving its performance, which employs a pyramid of binary volumes to encode spatial coherence present in the data and uses an opacity threshold to adaptively terminate ray tracing.
Journal ArticleDOI

Review of MR image segmentation techniques using pattern recognition.

TL;DR: This paper has reviewed, with somewhat variable coverage, the nine MR image segmentation techniques itemized in Table II; each has its merits and drawbacks.
Journal ArticleDOI

Magnetic Position and Orientation Tracking System

TL;DR: In this article, linear rotation transformations based upon the previous measurements are applied to both the source excitation and sensor output vectors, yielding quantities that are linearly propotional to small changes in the position and orientation.
Journal ArticleDOI

Multidimensional transfer functions for interactive volume rendering

TL;DR: An important class of 3D transfer functions for scalar data is demonstrated, and the application of multi-dimensional transfer functions to multivariate data is described, and a set of direct manipulation widgets that make specifying such transfer functions intuitive and convenient are presented.
Related Papers (5)