scispace - formally typeset
Journal ArticleDOI

Three-Dimensional Ultrasound Imaging

Reads0
Chats0
TLDR
A review article describes the developments of a number of 3D ultrasound imaging systems using mechanical, free-hand and 2D array scanning techniques and the sources of errors in the reconstruction techniques as well as formulae relating design specification to geometric errors.
Abstract
Ultrasound is an inexpensive and widely used imaging modality for the diagnosis and staging of a number of diseases. In the past two decades, it has benefited from major advances in technology and has become an indispensable imaging modality, due to its flexibility and non-invasive character. In the last decade, research investigators and commercial companies have further advanced ultrasound imaging with the development of 3D ultrasound. This new imaging approach is rapidly achieving widespread use with numerous applications. The major reason for the increase in the use of 3D ultrasound is related to the limitations of 2D viewing of 3D anatomy, using conventional ultrasound. This occurs because: (a) Conventional ultrasound images are 2D, yet the anatomy is 3D, hence the diagnostician must integrate multiple images in his mind. This practice is inefficient, and may lead to variability and incorrect diagnoses. (b) The 2D ultrasound image represents a thin plane at some arbitrary angle in the body. It is difficult to localize the image plane and reproduce it at a later time for follow-up studies. In this review article we describe how 3D ultrasound imaging overcomes these limitations. Specifically, we describe the developments of a number of 3D ultrasound imaging systems using mechanical, free-hand and 2D array scanning techniques. Reconstruction and viewing methods of the 3D images are described with specific examples. Since 3D ultrasound is used to quantify the volume of organs and pathology, the sources of errors in the reconstruction techniques as well as formulae relating design specification to geometric errors are provided. Finally, methods to measure organ volume from the 3D ultrasound images and sources of errors are described.

read more

Citations
More filters
Journal ArticleDOI

Deep learning-based carotid media-adventitia and lumen-intima boundary segmentation from three-dimensional ultrasound images

TL;DR: A semiautomatic segmentation method based on deep learning to segment the MAB and LIB from carotid three‐dimensional ultrasound (3DUS) images shows high accuracy and repeatability with less user interactions, suggesting that the method could be used in clinical practice to measure VWV and monitor the progression and regression ofcarotid plaques.
Journal ArticleDOI

A high frequency cMUT probe for ultrasound imaging of fingerprints

TL;DR: In this paper, a 192-element array with a frequency band centered at 12.5 MHz was used for fingerprint imaging using ultrasound transducers, which can be profitably exploited in biometric applications, like fingerprint or palm print.
Journal ArticleDOI

Three-dimensional ultrasound imaging for the evaluation of carotid atherosclerosis

TL;DR: Evidence supports the good reproducibility of the 3D US on the evaluation of carotid plaque volume, however with high heterogeneity between studies, and preliminary evidence that PV measurements may be more sensitive than IMT in the identification of plaque change post-treatment, though, more plaque-related evidence is necessary.
Journal ArticleDOI

Functional Neoangiogenesis Imaging of Genetically Engineered Mouse Prostate Cancer Using Three-Dimensional Power Doppler Ultrasound

TL;DR: The first application of high-frequency three-dimensional power Doppler ultrasound imaging in a genetically engineered mouse (GEM) prostate cancer model is reported, showing that the technology sensitively and specifically depicts functional neoangiogenic blood flow, which likely accounts for the continued growth of the tumors after surgery.
Journal ArticleDOI

Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system.

TL;DR: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B and can be applied to any type of catheters and applicators.
References
More filters
Journal ArticleDOI

Deformable models in medical image analysis: a survey

TL;DR: The rapidly expanding body of work on the development and application of deformable models to problems of fundamental importance in medical image analysis, including segmentation, shape representation, matching and motion tracking is reviewed.
Journal ArticleDOI

Efficient ray tracing of volume data

TL;DR: This paper presents a front-to-back image-order volume-rendering algorithm and discusses two techniques for improving its performance, which employs a pyramid of binary volumes to encode spatial coherence present in the data and uses an opacity threshold to adaptively terminate ray tracing.
Journal ArticleDOI

Review of MR image segmentation techniques using pattern recognition.

TL;DR: This paper has reviewed, with somewhat variable coverage, the nine MR image segmentation techniques itemized in Table II; each has its merits and drawbacks.
Journal ArticleDOI

Magnetic Position and Orientation Tracking System

TL;DR: In this article, linear rotation transformations based upon the previous measurements are applied to both the source excitation and sensor output vectors, yielding quantities that are linearly propotional to small changes in the position and orientation.
Journal ArticleDOI

Multidimensional transfer functions for interactive volume rendering

TL;DR: An important class of 3D transfer functions for scalar data is demonstrated, and the application of multi-dimensional transfer functions to multivariate data is described, and a set of direct manipulation widgets that make specifying such transfer functions intuitive and convenient are presented.
Related Papers (5)