TLDR
A review article describes the developments of a number of 3D ultrasound imaging systems using mechanical, free-hand and 2D array scanning techniques and the sources of errors in the reconstruction techniques as well as formulae relating design specification to geometric errors.
Abstract
Ultrasound is an inexpensive and widely used imaging modality for the diagnosis and staging of a number of diseases. In the past two decades, it has benefited from major advances in technology and has become an indispensable imaging modality, due to its flexibility and non-invasive character. In the last decade, research investigators and commercial companies have further advanced ultrasound imaging with the development of 3D ultrasound. This new imaging approach is rapidly achieving widespread use with numerous applications. The major reason for the increase in the use of 3D ultrasound is related to the limitations of 2D viewing of 3D anatomy, using conventional ultrasound. This occurs because: (a) Conventional ultrasound images are 2D, yet the anatomy is 3D, hence the diagnostician must integrate multiple images in his mind. This practice is inefficient, and may lead to variability and incorrect diagnoses. (b) The 2D ultrasound image represents a thin plane at some arbitrary angle in the body. It is difficult to localize the image plane and reproduce it at a later time for follow-up studies. In this review article we describe how 3D ultrasound imaging overcomes these limitations. Specifically, we describe the developments of a number of 3D ultrasound imaging systems using mechanical, free-hand and 2D array scanning techniques. Reconstruction and viewing methods of the 3D images are described with specific examples. Since 3D ultrasound is used to quantify the volume of organs and pathology, the sources of errors in the reconstruction techniques as well as formulae relating design specification to geometric errors are provided. Finally, methods to measure organ volume from the 3D ultrasound images and sources of errors are described.

read more

Citations
More filters
Proceedings ArticleDOI

Realistic acoustic simulation of 2-D probe elements in simulated annealing sparse array optimization

TL;DR: In this study, the benefits of integrating a realistic acoustic simulation in the 2-D non-grid sparse array design are investigated and the same acoustic radiation of the probe during the optimization as in reality yields promising results.
Proceedings ArticleDOI

Imaging Spinal Curvatures of AIS Patients using 3D US Free-hand Fast Reconstruction Method

TL;DR: 3D US reconstruction algorithms which can reduce the reconstruction time to the required range of real-time demonstration and processing and to improve the US image quality for higher brightness and contrast are developed.
Journal ArticleDOI

The Effects of Positioning on the Volume/Location of the Internal Jugular Vein Using 2-Dimensional Tracked Ultrasound

TL;DR: This new 3D reconstruction method permits the creation of a 3D volume through a tracked 2D ultrasound scanning system with image acquisition and integration and may prove useful in providing the user with a "road map" of the vascular anatomy of a patient's neck or other anatomic structures.
Journal ArticleDOI

A real-time data-based scan conversion method for single element ultrasound transducers.

TL;DR: The scan conversion algorithm was validated by evaluation of the position estimation errors on both simulations and experiments and showed that the calibration curve is robust to changes in scatterer concentration, signal to noise ratio, and can be accurately predicted from a small number of point scatterers.
Journal ArticleDOI

Population balance modelling for high concentration nanoparticle sizing with ultrasound Spectroscopy

TL;DR: In this article, a method using population balance (PB) was used to deal with the high-concentration PSD problem for silica suspensions, and the authors concluded that with a deaggregation model, it is possible to convert attenuation inverted PSDs at high concentrations into the PSD that is thought to be the correct PSD at a critical low concentration by a population balance simulation.
References
More filters
Journal ArticleDOI

Deformable models in medical image analysis: a survey

TL;DR: The rapidly expanding body of work on the development and application of deformable models to problems of fundamental importance in medical image analysis, including segmentation, shape representation, matching and motion tracking is reviewed.
Journal ArticleDOI

Efficient ray tracing of volume data

TL;DR: This paper presents a front-to-back image-order volume-rendering algorithm and discusses two techniques for improving its performance, which employs a pyramid of binary volumes to encode spatial coherence present in the data and uses an opacity threshold to adaptively terminate ray tracing.
Journal ArticleDOI

Review of MR image segmentation techniques using pattern recognition.

TL;DR: This paper has reviewed, with somewhat variable coverage, the nine MR image segmentation techniques itemized in Table II; each has its merits and drawbacks.
Journal ArticleDOI

Magnetic Position and Orientation Tracking System

TL;DR: In this article, linear rotation transformations based upon the previous measurements are applied to both the source excitation and sensor output vectors, yielding quantities that are linearly propotional to small changes in the position and orientation.
Journal ArticleDOI

Multidimensional transfer functions for interactive volume rendering

TL;DR: An important class of 3D transfer functions for scalar data is demonstrated, and the application of multi-dimensional transfer functions to multivariate data is described, and a set of direct manipulation widgets that make specifying such transfer functions intuitive and convenient are presented.
Related Papers (5)