scispace - formally typeset
Journal ArticleDOI

Three-Dimensional Ultrasound Imaging

Reads0
Chats0
TLDR
A review article describes the developments of a number of 3D ultrasound imaging systems using mechanical, free-hand and 2D array scanning techniques and the sources of errors in the reconstruction techniques as well as formulae relating design specification to geometric errors.
Abstract
Ultrasound is an inexpensive and widely used imaging modality for the diagnosis and staging of a number of diseases. In the past two decades, it has benefited from major advances in technology and has become an indispensable imaging modality, due to its flexibility and non-invasive character. In the last decade, research investigators and commercial companies have further advanced ultrasound imaging with the development of 3D ultrasound. This new imaging approach is rapidly achieving widespread use with numerous applications. The major reason for the increase in the use of 3D ultrasound is related to the limitations of 2D viewing of 3D anatomy, using conventional ultrasound. This occurs because: (a) Conventional ultrasound images are 2D, yet the anatomy is 3D, hence the diagnostician must integrate multiple images in his mind. This practice is inefficient, and may lead to variability and incorrect diagnoses. (b) The 2D ultrasound image represents a thin plane at some arbitrary angle in the body. It is difficult to localize the image plane and reproduce it at a later time for follow-up studies. In this review article we describe how 3D ultrasound imaging overcomes these limitations. Specifically, we describe the developments of a number of 3D ultrasound imaging systems using mechanical, free-hand and 2D array scanning techniques. Reconstruction and viewing methods of the 3D images are described with specific examples. Since 3D ultrasound is used to quantify the volume of organs and pathology, the sources of errors in the reconstruction techniques as well as formulae relating design specification to geometric errors are provided. Finally, methods to measure organ volume from the 3D ultrasound images and sources of errors are described.

read more

Citations
More filters
Proceedings ArticleDOI

Multimodal speech recognition with ultrasonic sensors.

TL;DR: Experiments performed on a noisy continuous digit recognition task indicate that the addition of ultrasonic information reduces word error rates by 24-29% over a wide range of acoustic SNR (20-0 dB).
Journal ArticleDOI

Area-preserving flattening maps of 3D ultrasound carotid arteries images.

TL;DR: A technique to flatten the 3D VWT and VWT-Change maps in an area-preserving manner, in order to facilitate the visualization and interpretation of these maps, is proposed.
Journal ArticleDOI

Fast block flow tracking of atrial septal defects in 4D echocardiography.

TL;DR: A block flow technique, which combines the velocity computation from optical flow for an entire block with template matching, which tracks ASD motion at 2 frames/s, much faster than optical flow and comparable in computation cost to block matching, and shows promise for real-time.
Journal ArticleDOI

Performance of ultrasound based measurement of 3D displacement using a curvilinear probe for organ motion tracking.

TL;DR: The tracking performance was found to be best for axial displacements and poorest for elevational displacements, although the nature of the depth dependence was complex and the performance was sufficient to be useful for monitoring organ motion.
Journal ArticleDOI

Experimental evaluation of an ultrasound technique for the biometric recognition of human hand anatomic elements.

TL;DR: The results have shown that, in the analysed region, there are several anatomic elements (including hand bones, bending tendons, muscle tissue, blood vessels) that can be exploited for measurements of biometric parameters.
References
More filters
Journal ArticleDOI

Deformable models in medical image analysis: a survey

TL;DR: The rapidly expanding body of work on the development and application of deformable models to problems of fundamental importance in medical image analysis, including segmentation, shape representation, matching and motion tracking is reviewed.
Journal ArticleDOI

Efficient ray tracing of volume data

TL;DR: This paper presents a front-to-back image-order volume-rendering algorithm and discusses two techniques for improving its performance, which employs a pyramid of binary volumes to encode spatial coherence present in the data and uses an opacity threshold to adaptively terminate ray tracing.
Journal ArticleDOI

Review of MR image segmentation techniques using pattern recognition.

TL;DR: This paper has reviewed, with somewhat variable coverage, the nine MR image segmentation techniques itemized in Table II; each has its merits and drawbacks.
Journal ArticleDOI

Magnetic Position and Orientation Tracking System

TL;DR: In this article, linear rotation transformations based upon the previous measurements are applied to both the source excitation and sensor output vectors, yielding quantities that are linearly propotional to small changes in the position and orientation.
Journal ArticleDOI

Multidimensional transfer functions for interactive volume rendering

TL;DR: An important class of 3D transfer functions for scalar data is demonstrated, and the application of multi-dimensional transfer functions to multivariate data is described, and a set of direct manipulation widgets that make specifying such transfer functions intuitive and convenient are presented.
Related Papers (5)