scispace - formally typeset
Search or ask a question
Institution

Bethesda Hospital

HealthcareAmbur, Tamil Nadu, India
About: Bethesda Hospital is a healthcare organization based out in Ambur, Tamil Nadu, India. It is known for research contribution in the topics: Population & Helicobacter pylori. The organization has 386 authors who have published 472 publications receiving 15193 citations.


Papers
More filters
Journal ArticleDOI
TL;DR: Recurrent implantation failure (RIF) is repeated unsuccessful embryo transfers (ETs) that occur after at least two attempts at implantation.
Abstract: Background Recurrent implantation failure (RIF) is repeated unsuccessful embryo transfers (ETs). Aims To identify predictive embryonic markers of implantation in RIF, following pre-implantation genetic screening (PGS) of cleavage stage embryos, after accounting for male and female factors. Materials and methods Retrospective analysis of RIF patients undergoing PGS after correction of modifiable causes. Results Eighty-four patients underwent 140 in vitro ferilisation cycles. Forty-one cycles were excluded: 12 (no embryo for transfer), four (double ETs) and 25 (no biopsy). Sixty-three patients underwent 99 single euploid ETs (48 fresh, 51 frozen) resulting in 11 biochemical pregnancies, 36 clinical pregnancies (CP), and six miscarriages and 30 live births (LB). Frozen ET was more successful than fresh; respective live birth rate (LBR) and clinical pregnancy rate (CPR), 39.2% versus 20.8%, (P = 0.02), 45.1% versus 27.1% (P = 0.04). LBR and CPR were lower when 5-6 blastomeres were present at embryo biopsy, compared to embryos with ≥7 blastomeres: 15.4% versus 32.6% (P = 0.185) and 15.4% versus 39.5% (P = 0.074) respectively. Serum β human chorionic gonadotropin (βhCG) concentration was greater when a more developed embryo was biopsied (r = 0.448, P = 0.017 and r = 0.476, P = 0.118, fresh and frozen transfers, respectively). Embryo morphokinetic analysis demonstrated faster development to blastocyst stage when more cells were present at biopsy: mean 103.3, 102.2 and 96.0 h for biopsy at the 5-6, 7-8 or ≥9 cell stage respectively (P = 0.040 for difference between 7-8 cells vs ≥9). Conclusions After cleavage stage biopsy, frozen ET was more successful than fresh ET. Chance of conception and serum βhCG concentration correlated with number of cells present at time of biopsy.

6 citations

Journal ArticleDOI
TL;DR: In this paper, the Alzheimer's type, DAT (dementia of the DAT) type, 6명을 대상으로 친숙도를 활용한 의미자질(semantic feature analysis, SFA)
Abstract: 배경 및 목적: 초기 알츠하이머성 치매(dementia of the Alzheimer's type, DAT)환자 6명을 대상으로 친숙도를 활용한 의미자질(semantic feature analysis, SFA)중재가 중재 및 비중재 명사 이름대기, 기타 이름대기, 표준화된 언어 및 인지검사 과제에서 유의한 차이가 있는지 살펴보았다. 방법: 3명은...

6 citations

Journal ArticleDOI
TL;DR: The reliability of 3D ultrasound of the supraspinatus tendon depends on the level of experience of the sonographer, and new diagnostic criteria have to be established and taught even to experienced 2D sonographers to improve reproducibility.
Abstract: BACKGROUND Three-dimensional (3D) ultrasound of the shoulder is characterized by a comparable accuracy to two-dimensional (2D) ultrasound. No studies investigating 2D versus 3D inter-rater reliability in the detection of supraspinatus tendon tears taking into account the level of experience of the raters have been carried out so far. OBJECTIVES The aim of this study was to determine the inter-rater reliability in the analysis of 3D ultrasound image sets of the supraspinatus tendon between sonographer with different levels of experience. PATIENTS AND METHODS Non-interventional, prospective, observational pilot study of 2309 images of 127 adult patients suffering from unilateral shoulder pain. 3D ultrasound image sets were scored by three raters independently. The intra-and interrater reliabilities were calculated. RESULTS There was an excellent intra-rater reliability of rater A in the overall classification of supraspinatus tendon tears (2D vs 3D κ = 0.892, pairwise reliability 93.81%, 3D scoring round 1 vs 3D scoring round 2 κ = 0.875, pairwise reliability 92.857%). The inter-rater reliability was only moderate compared to rater B on 3D (κ = 0.497, pairwise reliability 70.95%) and fair compared to rater C (κ = 0.238, pairwise reliability 42.38%). CONCLUSIONS The reliability of 3D ultrasound of the supraspinatus tendon depends on the level of experience of the sonographer. Experience in 2D ultrasound does not seem to be sufficient for the analysis of 3D ultrasound imaging sets. Therefore, for a 3D ultrasound analysis new diagnostic criteria have to be established and taught even to experienced 2D sonographers to improve reproducibility.

6 citations

Journal ArticleDOI
TL;DR: A case of B-cell origin is reported in which both immunophenotypic and genotypic studies performed on a cell suspension of the lymphoma gave inconclusive and potentially misleading information, while paraffin and frozen section immunohistologic studies, as well as genotypo-genotypes performed on DNA obtained from snap-frozen tissue, were definitive.

6 citations


Authors

Showing all 387 results

NameH-indexPapersCitations
Jennie Ponsford7339318379
Peter J. Stern532358622
Roger Hart461547065
Glynda J. Kinsella401205752
Jacinta Douglas391804737
Gabriela Möslein361126057
Pamela Claire Snow361424496
Michael Denkinger341473214
Thomas Daikeler301413309
John Olver251033189
J. C. Thijs24462194
Daniel Navot24562705
Bernd Sanner231022652
Ulrike Nitz22984068
Dries Testelmans22922100
Network Information
Related Institutions (5)
NewYork–Presbyterian Hospital
25.3K papers, 1M citations

82% related

Cleveland Clinic
79.3K papers, 3.4M citations

82% related

VU University Medical Center
22.9K papers, 1.1M citations

81% related

Kaiser Permanente
24.3K papers, 1.2M citations

81% related

Beth Israel Deaconess Medical Center
52.5K papers, 2.9M citations

81% related

Performance
Metrics
No. of papers from the Institution in previous years
YearPapers
20223
202148
202039
201927
201819
201723