Institution
Hospital General Universitario Gregorio Marañón
Healthcare•Madrid, Spain•
About: Hospital General Universitario Gregorio Marañón is a healthcare organization based out in Madrid, Spain. It is known for research contribution in the topics: Population & Transplantation. The organization has 11975 authors who have published 12386 publications receiving 244847 citations.
Topics: Population, Transplantation, Medicine, Myocardial infarction, Cancer
Papers published on a yearly basis
Papers
More filters
••
TL;DR: Doppler-derived EIVPDs provide quantitative, reproducible, and relatively load-independent indices of global systolic chamber function that correlate closely with currently available reference methods.
Abstract: Background— Ejection intraventricular pressure gradients are caused by the systolic force developed by the left ventricle (LV). By postprocessing color Doppler M-mode (CDMM) images, we can measure noninvasively the ejection intraventricular pressure difference (EIVPD) between the LV apex and the outflow tract. This study was designed to assess the value of Doppler-derived EIVPDs as noninvasive indices of systolic chamber function. Methods and Results— CDMM images and pressure-volume (conductance) signals were simultaneously acquired in 9 minipigs undergoing pharmacological interventions and acute ischemia. Inertial, convective, and total EIVPD curves were calculated from CDMM recordings. Peak EIVPD closely correlated with indices of systolic function based on the pressure-volume relationship: peak elastance (within-animal R=0.98; between-animals R=0.99), preload recruitable stroke work (within-animal R=0.81; between-animals R=0.86), and peak of the first derivative of pressure corrected for end-diastolic ...
81 citations
••
TL;DR: The response rate to hepatitis B virus (HBV) vaccination in patients with inflammatory bowel disease (IBD) is low and the need for further studies is to be determined.
Abstract: Summary
Background
The response rate to hepatitis B virus (HBV) vaccination in patients with inflammatory bowel disease (IBD) is low.
Aim
To compare two vaccination protocols—the standard dose and the double dose—in IBD patients.
Methods
Patients diagnosed with IBD from three tertiary hospitals were vaccinated against HBV with two different protocols: the standard protocol (Engerix-B single dose at 0, 1 and 6 months) and the new faster protocol based on a double dose (Engerix B double dose at 0, 1 and 2 months). Anti-HBs titres were measured 1–3 months after the last dose. A multivariate analysis was performed to identify factors that were predictive of response to the vaccine.
Results
The study sample comprised 148 patients (mean age 40 years, 69% Crohn's disease), 70% of whom were receiving immunosuppressive therapy (22% thiopurines, 23% anti-TNF and 25% both). The standard protocol was followed in 46% of patients and the double dose protocol in 54%. Considering anti-HBs >10 IU/L as a successful response to vaccination, the seroconversion rate was higher among patients vaccinated with the double dose than with the standard dose: 75% (95% CI, 65–85%) vs. 41% (95% CI, 29–54%) (P < 0.001). In the multivariate analysis, vaccination with the double dose was the only factor associated with a better response to the vaccine (OR, 4; 95% CI, 2–8; P < 0.001).
Conclusions
The response rate to the HBV vaccination in IBD patients is low. Administration of a double dose was associated with a higher response rate. Therefore, the double dose protocol could be a suitable option in patients with IBD.
81 citations
••
TL;DR: Digitally planned and executed osteotomies under 3D printed osteotomy positioning guides help the surgeon to minimize human error while reducing surgical time and achieving a high-axis correction accuracy compared with the standard technique.
Abstract: Opening wedge osteotomy has recently gained popularity, thanks to the recent implementation of locking plates, which have shown equivalent stability with greater reproducibility, accuracy, and longevity than the closing wedge techniques and a lower prosthetic conversion rate. We present a new "do-it-yourself" cutting guides system for tibial opening osteotomy. Using a conventional computed tomography digital image, a positioning guide and wedge spacers were printed in three dimensions (3D) for implementing the osteotomy and obtaining the planned correction. The surgeon makes the whole process in a do-it-yourself style. This new technique was used in eight cases. Previous opening osteotomies with the standard technique were used as control (20 cases). Surgical time, fluoroscopic time, and accuracy of the axial correction were measured. The use of a custom positioning guide reduced the surgical (31 minutes less) and fluoroscopic times (6.9 times less) while achieving a high-axis correction accuracy compared with the standard technique. Digitally planned and executed osteotomies under 3D printed osteotomy positioning guides help the surgeon to minimize human error while reducing surgical time. The reproducibility of this technique is very robust, allowing a transfer of the steps planned in a virtual environment to the operating table.
81 citations
••
TL;DR: Although the underlying mechanism of COVID‐19 coagulopathy remains unknown, it has been suggested to be a form of disseminated intravascular coagulation (DIC).
Abstract: Background: Abnormal coagulation parameters have been reported in COVID-19-infected patients. Although the underlying mechanism of COVID-19 coagulopathy remains unknown, it has been suggested to be a form of disseminated intravascular coagulation (DIC). Objectives: The aim of our study was to analyze the coagulation parameters of patients with COVID-19, determine whether coagulation factors consumption occurs and identify potential prognostic biomarkers of the disease. Patients/Methods: Blood samples from hospitalized patients with COVID-19 pneumonia were collected. We performed basic coagulation tests and quantification of coagulation factors and physiological inhibitor proteins. Laboratory data were compared with clinical data and outcomes. Results: The study involved 206 patients (63.6% male). D-dimer was particularly elevated (median 450 ng/mL; IQR 222.5-957.3). Free protein S levels were below the normal range (median 56.6%; IQR: 43.6-68.9), and factor VIII showed an increasing trend (median 173.4%; IQR: 144.1-214.9). However, all coagulation factors were within normal limits. We found no correlation between abnormal coagulation parameters and thrombosis, except for higher D-dimer (HR 1.99; 95% CI 1.3-3.1; P =.002). Conclusions: COVID-19 is associated with coagulopathy that correlates with poor prognosis. However, we did not demonstrate a consumption of coagulation factors, as seen in DIC.
81 citations
••
TL;DR: In patients with a standard SC-icD indication, DC-ICD was associated with less CSAE when compared with SC- ICD, and this randomized trial evaluated clinically significant adverse events (CSAEs) in patients implanted with dual-chamber (DC) vs. single-chambers (SC) implantable cardioverter defibrillator (ICD).
Abstract: Aims This randomized trial evaluated clinically significant adverse events (CSAEs), in patients implanted with dual-chamber (DC) vs. single-chamber (SC) implantable cardioverter defibrillator (ICD). DC-ICD had atrial tachyarrhythmia (AT) therapy capabilities. Strict programming recommendations were reinforced. Methods and results Patients with conventional SC-ICD indication were randomized to DC-ICD, SC-ICD, or a DC-ICD programmed as an SC-ICD (SC-simulated) and followed for 16 months. Patients in the DC and SC-simulated groups crossed over after 8 months. The primary endpoint was a composite of CSAE: all-cause mortality; invasive intervention; hospitalization (> 24 h) for cardiovascular causes; inappropriate shocks (two or more episodes); and sustained symptomatic AT lasting > 48 h. The outcome variable was a pre-specified score that corrected for clinical severity and follow-up duration. Three hundred and thirty-four patients were analysed (DC-ICD, n = 112; SC-ICD, n = 111; SC-simulated, n = 111). The mean left ventricular ejection fraction was 0.36 +/- 0.13, 69% were in functional class > or = II. CSAE occurred in 65 DC-ICD, 82 SC-ICD, and 84 SC-simulated patients. The outcome variable was 33% lower in the DC-ICD group (OR 0.31; 95% CI 0.14-0.67; P = 0.0028). Mortality was 4% in DC, 9% in SC, and 10% in SC-simulated. Conclusion In patients with a standard SC-ICD indication, DC-ICD was associated with less CSAE when compared with SC-ICD.
81 citations
Authors
Showing all 12014 results
Name | H-index | Papers | Citations |
---|---|---|---|
David H. Adams | 155 | 1613 | 117783 |
Stefanie Dimmeler | 147 | 574 | 81658 |
Stuart J. Pocock | 145 | 684 | 143547 |
M. I. Martínez | 134 | 1251 | 79885 |
Guy A. Rouleau | 129 | 884 | 65892 |
Jose L. Jimenez | 124 | 654 | 64226 |
Antoni Torres | 120 | 1238 | 65049 |
Paul P. Tak | 112 | 591 | 57689 |
Luis A. Diaz | 111 | 596 | 75036 |
Frans Van de Werf | 109 | 747 | 63537 |
José Luis Zamorano | 105 | 695 | 133396 |
Francisco Sánchez-Madrid | 102 | 527 | 43418 |
Francesco Locatelli | 99 | 820 | 42454 |
Roberto M. Lang | 96 | 823 | 56638 |
Carlos Simón | 95 | 589 | 31147 |