scispace - formally typeset
Open AccessJournal ArticleDOI

Evaluation of a new pocket echoscopic device for focused cardiac ultrasonography in an emergency setting.

TLDR
In an emergency setting, this new ultraportable echoscope (PUD) was reliable for the real-time detection of focused cardiac abnormalities.
Abstract
Introduction In the emergency setting, focused cardiac ultrasound has become a fundamental tool for diagnostic, initial emergency treatment and triage decisions. A new ultra-miniaturized pocket ultrasound device (PUD) may be suited to this specific setting. Therefore, we aimed to compare the diagnostic ability of an ultra-miniaturized ultrasound device (Vscan™, GE Healthcare, Wauwatosa, WI) and of a conventional high-quality echocardiography system (Vivid S5™, GE Healthcare) for a cardiac focused ultrasonography in patients admitted to the emergency department.

read more

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI

Impact of device selection and clip duration on lung ultrasound assessment in patients with heart failure.

TL;DR: Findings suggest significant differences based on LUS clip duration rather than the type of ultrasound device used, with respect to the number of B-lines detectable in patients with heart failure.
Journal ArticleDOI

Can Hospital Rounds With Pocket Ultrasound By Cardiologists Reduce Standard Echocardiography

TL;DR: The results from rapid bedside pocket mobile echocardiography examinations performed by experienced cardiology fellows compared favorably with those from formal transthoracic echOCardiography studies, which could shift the burden of performing and interpreting the eChocardiogram to the examining physician and reduce the number and cost associated with formal echoportalography studies.
Journal ArticleDOI

Bedside POCUS during ward emergencies is associated with improved diagnosis and outcome: an observational, prospective, controlled study

TL;DR: In this article, a prospective, observational, controlled study was conducted in a single university hospital to assess the impact of implementing such a POCUS-guided management on the proportion of adequate immediate diagnoses in two groups.
Journal ArticleDOI

Impact of pocket ultrasound use by internal medicine housestaff in the diagnosis of dyspnea.

TL;DR: In this article, the feasibility of training internal medicine residents in lung ultrasound with a pocket ultrasound device was assessed and two residents received an additional 2 weeks of training and showed an increase in diagnostic accuracy.
Journal ArticleDOI

Internal medicine point-of-care ultrasound assessment of left ventricular function correlates with formal echocardiography.

TL;DR: Although focused cardiac ultrasonographic examination has been evaluated in emergency departments and intensive care units with good correlation to formal echocardiography, accuracy for the assessment of left ventricular systolic function (LVSF) when performed by internal medicine physicians still needs independent evaluation.
References
More filters
Journal ArticleDOI

The measurement of observer agreement for categorical data

TL;DR: A general statistical methodology for the analysis of multivariate categorical data arising from observer reliability studies is presented and tests for interobserver bias are presented in terms of first-order marginal homogeneity and measures of interob server agreement are developed as generalized kappa-type statistics.
Journal ArticleDOI

Statistical methods for assessing agreement between two methods of clinical measurement.

TL;DR: An alternative approach, based on graphical techniques and simple calculations, is described, together with the relation between this analysis and the assessment of repeatability.
Journal ArticleDOI

A Coefficient of agreement for nominal Scales

TL;DR: In this article, the authors present a procedure for having two or more judges independently categorize a sample of units and determine the degree, significance, and significance of the units. But they do not discuss the extent to which these judgments are reproducible, i.e., reliable.
Journal ArticleDOI

Recommendations for chamber quantification

TL;DR: This document reviews the technical aspects on how to perform quantitative chamber measurements of morphology and function, which is a component of every complete echocardiographic examination.
Journal ArticleDOI

Point-of-Care Ultrasonography

TL;DR: This review includes videos demonstrating the use of ultrasonography to guide central venous access, detect pneumothorax, detect evidence of hemorrhage after trauma, and screen for abdominal aortic aneurysm.