scispace - formally typeset
Journal ArticleDOI

Molecular rotors--fluorescent biosensors for viscosity and flow.

Reads0
Chats0
TLDR
Molecular rotors are emerging as new biosensors for both bulk and local microviscosity, and for flow and fluid shear stress on a microscopic scale and with real-time response.
Abstract
Viscosity is a measure of the resistance of a fluid against gradients in flow (shear rate). Both flow and viscosity play an important role in all biological systems from the microscopic (e.g., cellular) to the systemic level. Many methods to measure viscosity and flow have drawbacks, such as the tedious and time-consuming measurement process, expensive instrumentation, or the restriction to bulk sample sizes. Fluorescent environment-sensitive dyes are known to show high sensitivity and high spatial and temporal resolution. Molecular rotors are a group of fluorescent molecules that form twisted intramolecular charge transfer (TICT) states upon photoexcitation and therefore exhibit two competing deexcitation pathways: fluorescence emission and non-radiative deexcitation from the TICT state. Since TICT formation is viscosity-dependent, the emission intensity of molecular rotors depends on the solvent's viscosity. Furthermore, shear-stress dependency of the emission intensity was recently described. Although the photophysical processes are widely explored, the practical application of molecular rotors as sensors for viscosity and the fluid flow introduce additional challenges. Intensity-based measurements are influenced by fluid optical properties and dye concentration, and solvent–dye interaction requires calibration of the measurement system to a specific solvent. Ratiometric dyes and measurement systems help solve these challenges. In addition, the combination of molecular rotors with specific recognition groups allows them to target specific sites, for example the cell membrane or cytoplasm. Molecular rotors are therefore emerging as new biosensors for both bulk and local microviscosity, and for flow and fluid shear stress on a microscopic scale and with real-time response.

read more

Citations
More filters
Proceedings ArticleDOI

Probing energy metabolism and microviscosity in cancer using FLIM

TL;DR: The data suggest that the cisplatin-induced changes in cellular metabolism and membrane viscosity play a role in the cytotoxicity of the drug.
Journal ArticleDOI

A Heparin based dual ratiometric sensor for Thrombin.

TL;DR: The present system offers a ratiometric response that has the ability for robust quantification of Thrombin concentration even in complex medium and the involvement of all commercially available components is a crucial advantage of this detection scheme.
Journal ArticleDOI

Impact of viscosity on photo-induced bimodal emission, decay profile and energy transfer in lanthanide based hybrid nanostructure

TL;DR: In this paper, the effect of viscous media on fluorescence intensity and lifetime of hybrid nanoparticles (HNPs) have been investigated in order to design viscosity sensor HNPs are developed by using of Eu(TTA)3Phen (ETP) coordination compound and NaGd078Er002Yb020F4 fluoride nanoparticles Here ETP gives strong emission in orange-red region at 611-nm wavelength by absorbing ultraviolet (UV) {240-450 nm) photons (known as downshifting process, DS) and
Journal ArticleDOI

Real-time monitoring viscosity variation in carcinogenesis evolution models by a red-emitting rotor

TL;DR: In this article, a new viscosity sensitive fluorescent probe (TA-I) with large Stokes shift and high visosity dependence is designed to visualize the viscohesion level of tumors at different growth stages.
Journal ArticleDOI

A molecular rotor based dual ratiometric sensor for heparinase

TL;DR: A selective and sensitive fluorescence ratiometric sensor for the detection of Heparinase that has been developed by utilizing a fluorescent complex of a molecular rotor dye, Thioflavin T with Heparin, which provides a simple, sensitive, selective, and label-free approach for detection.
References
More filters
Journal ArticleDOI

The fluid mosaic model of the structure of cell membranes.

TL;DR: Results strongly indicate that the bivalent antibodies produce an aggregation of the surface immunoglobulin molecules in the plane of the membrane, which can occur only if the immunoglOBulin molecules are free to diffuse in the membrane.
Journal ArticleDOI

Mobility measurement by analysis of fluorescence photobleaching recovery kinetics.

TL;DR: The theoretical basis and some practical guidelines for simple, rigorous analysis of FPR experiments are presented and some model experiments on aqueous solutions of rhodamine 6G are described.
Journal ArticleDOI

Reinterpretation of the anomalous fluorescense of p-n,n-dimethylamino-benzonitrile

TL;DR: In this paper, the existence of two excited species differing in polarity and in the orientation of the N(CH 3 ) 2 group has been attributed to the presence of an excimer.
Related Papers (5)