Numerical simulation of x-ray luminescence optical tomography for small-animal imaging

Reads0
Chats0
TLDR
The heterogeneity of x-rays energy deposition is included in the XLOT-EP reconstruction and improves the reconstruction accuracy, suggesting that there is a need to calculate the x-ray energy distribution for experimental XLOT imaging.
Abstract
X-ray luminescence optical tomography (XLOT) is an emerging hybrid imaging modality in which x-ray excitable particles (phosphor particles) emit optical photons when stimulated with a collimated x-ray beam. XLOT can potentially combine the high sensitivity of optical imaging with the high spatial resolution of x-ray imaging. For reconstruction of XLOT data, we compared two reconstruction algorithms, conventional filtered backprojection (FBP) and a new algorithm, x-ray luminescence optical tomography with excitation priors (XLOT-EP), in which photon propagation is modeled with the diffusion equation and the x-ray beam positions are used as reconstruction priors. Numerical simulations based on dose calculations were used to validate the proposed XLOT imaging system and the reconstruction algorithms. Simulation results showed nanoparticle concentrations reconstructed with XLOT-EP are much less dependent on scan depth than those obtained with FBP. Measurements at just two orthogonal projections are sufficient for XLOT-EP to reconstruct an XLOT image for simple source distributions. The heterogeneity of x-ray energy deposition is included in the XLOT-EP reconstruction and improves the reconstruction accuracy, suggesting that there is a need to calculate the x-ray energy distribution for experimental XLOT imaging.

read more

Content maybe subject to copyright    Report

Citations
More filters
Journal ArticleDOI

Cone Beam X-ray Luminescence Computed Tomography Based on Bayesian Method

TL;DR: Results of numerical simulations and mouse experiments show that the self-adaptive Bayesian method significantly improves the CB-XLCT image quality as compared with conventional methods.
Journal ArticleDOI

Multiple pinhole collimator based X-ray luminescence computed tomography.

TL;DR: A multiple pinhole collimator based XLCT, in which multiple X-ray beams are generated to scan a sample at multiple positions simultaneously, is proposed, which requires much less measurement time.
Journal Article

MTF evaluation of a phosphor-coated CCD for x-ray imaging

TL;DR: The high spatial resolution currently demanded in mammography can be achieved with this imaging system based on a phosphor-coated charge-coupled device obtained by direct deposition of a gadolinium oxysulphide scintillator on the detector surface.
Journal ArticleDOI

Sensitivity study of x-ray luminescence computed tomography.

TL;DR: This study has, for the first time, compared the sensitivity of XLCT with that of traditional computed tomography (CT) for phosphor targets and found that XLCT's use of x-ray-induced photons provides much higher measurement sensitivity and contrast compared to CT.
Journal ArticleDOI

Sparse view cone beam X-ray luminescence tomography based on truncated singular value decomposition.

TL;DR: A truncated singular value decomposition (TSVD) based sparse view CB-XLCT reconstruction method is proposed and indicates that the proposed method could improve the imaging quality of multi-targets significantly in terms of localization accuracy, target shape, image contrast, and spatial resolution, when compared with conventional methods.
References
More filters
Journal ArticleDOI

Noninvasive laser-induced photoacoustic tomography for structural and functional in vivo imaging of the brain

TL;DR: In vivo noninvasive transdermal and transcranial imaging of the structure and function of rat brains by means of laser-induced photoacoustic tomography (PAT) is reported, which retains intrinsic optical contrast characteristics while taking advantage of the diffraction-limited high spatial resolution of ultrasound.

PENELOPE-2006: A Code System for Monte Carlo Simulation of Electron and Photon Transport

TL;DR: The PENELOPE as mentioned in this paper computer code system performs Monte Carlo simulation of coupled electron-photon transport in arbitrary materials for a wide energy range, from a few hundred eV to about 1 GeV.
Journal ArticleDOI

Looking and listening to light: the evolution of whole-body photonic imaging.

TL;DR: Emphasis is shifting to photonic methods that use tomographic principles to noninvasively image optical contrast at depths of several millimeters to centimeters with high sensitivity and sub-millimeter to millimeter resolution.
Journal ArticleDOI

The use of gold nanoparticles to enhance radiotherapy in mice.

TL;DR: This novel use of small gold nanoparticles permitted achievement of the high metal content in tumours necessary for significant high-Z radioenhancement in mice bearing subcutaneous EMT-6 mammary carcinomas.
Journal ArticleDOI

Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement

TL;DR: It is found that DOT provides for localization and quantification of exogenous tissue chromophore concentrations and the use of ICG, an albumin bound absorbing dye in plasma, demonstrates the potential to differentiate disease based on the quantified enhancement of suspicious lesions.
Related Papers (5)
Trending Questions (1)
How many projections to measure in x-ray fluorescence tomography vs the spatial resolution?

In x-ray luminescence optical tomography, two orthogonal projections are sufficient for reconstruction, offering high spatial resolution with minimal depth dependency compared to conventional methods.